• Something wrong with this record ?

Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting

J. Čapek, M. Machová, M. Fousová, J. Kubásek, D. Vojtěch, J. Fojt, E. Jablonská, J. Lipov, T. Ruml,

. 2016 ; 69 (-) : 631-9. [pub] 20160714

Language English Country Netherlands

Document type Journal Article

Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc17023715
003      
CZ-PrNML
005      
20171010104309.0
007      
ta
008      
170720s2016 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.msec.2016.07.027 $2 doi
035    __
$a (PubMed)27612756
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Čapek, Jaroslav $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic; Institute of Physics, Academy of Sciences of the Czech Republic (AS CR), Na Slovance 1999/2, 182 21 Prague 8, Czech Republic. Electronic address: capekj@fzu.cz.
245    10
$a Highly porous, low elastic modulus 316L stainless steel scaffold prepared by selective laser melting / $c J. Čapek, M. Machová, M. Fousová, J. Kubásek, D. Vojtěch, J. Fojt, E. Jablonská, J. Lipov, T. Ruml,
520    9_
$a Recently, porous metallic materials have been extensively studied as candidates for use in the fabrication of scaffolds and augmentations to repair trabecular bone defects, e.g. in surroundings of joint replacements. Fabricating these complex structures by using common approaches (e.g., casting and machining) is very challenging. Therefore, rapid prototyping techniques, such as selective laser melting (SLM), have been investigated for these applications. In this study, we characterized a highly porous (87 vol.%) 316L stainless steel scaffold prepared by SLM. 316L steel was chosen because it presents a biomaterial still widely used for fabrication of joint replacements and, from the practical point of view, use of the same material for fabrication of an augmentation and a joint replacement is beneficial for corrosion prevention. The results are compared to the reported properties of two representative nonporous 316L stainless steels prepared either by SLM or casting and subsequent hot forging. The microstructural and mechanical properties and the surface chemical composition and interaction with the cells were investigated. The studied material exhibited mechanical properties that were similar to those of trabecular bone (compressive modulus of elasticity ~0.15GPa, compressive yield strength ~3MPa) and cytocompatibility after one day that was similar to that of wrought 316L stainless steel, which is a commonly used biomaterial. Based on the obtained results, SLM is a suitable method for the fabrication of porous 316L stainless steel scaffolds with highly porous structures.
650    _2
$a nádorové buněčné linie $7 D045744
650    _2
$a tvar buňky $7 D048430
650    _2
$a modul pružnosti $x účinky léků $7 D055119
650    _2
$a lidé $7 D006801
650    _2
$a železo $x farmakologie $7 D007501
650    12
$a lasery $7 D007834
650    _2
$a testování materiálů $x metody $7 D008422
650    _2
$a fotoelektronová spektroskopie $7 D056951
650    _2
$a poréznost $7 D016062
650    _2
$a nerezavějící ocel $x farmakologie $7 D013193
650    _2
$a povrchové vlastnosti $7 D013499
650    _2
$a pevnost v tahu $x účinky léků $7 D013718
655    _2
$a časopisecké články $7 D016428
700    1_
$a Machová, Markéta $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Fousová, Michaela $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Kubásek, Jiří $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Vojtěch, Dalibor $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Fojt, Jaroslav $u Department of Metals and Corrosion Engineering, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Jablonská, Eva $7 xx0217179 $u Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Lipov, Jan $u Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
700    1_
$a Ruml, Tomáš $u Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague 6, Czech Republic.
773    0_
$w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 69, č. - (2016), s. 631-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/27612756 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20170720 $b ABA008
991    __
$a 20171010104331 $b ABA008
999    __
$a ok $b bmc $g 1239396 $s 984628
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 69 $c - $d 631-9 $e 20160714 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
LZP    __
$a Pubmed-20170720

Find record