A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy)
SS. Pedersen, MH. Mastenbroek, N. Carter, C. Barr, P. Neuzil, M. Scholten, PD. Lambiase, L. Boersma, JB. Johansen, DA. Theuns,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu srovnávací studie, časopisecké články, pozorovací studie
NLK
ProQuest Central
od 2012-08-15 do Před 2 měsíci
Nursing & Allied Health Database (ProQuest)
od 2012-08-15 do Před 2 měsíci
Health & Medicine (ProQuest)
od 2012-08-15 do Před 2 měsíci
- MeSH
- činnosti denního života MeSH
- defibrilátory implantabilní * MeSH
- dospělí MeSH
- fibrilace komor komplikace terapie MeSH
- implantace protézy metody MeSH
- komorová tachykardie komplikace terapie MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- náhlá srdeční smrt etiologie prevence a kontrola MeSH
- prospektivní studie MeSH
- registrace * MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- srovnávací studie MeSH
The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of life (QoL) is not known. We evaluated the QoL of patients with an S-ICD against an unrelated cohort with a transvenous (TV)-ICD system during 6 months of follow-up. Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system on a priori selected variables including baseline QoL. QoL was measured with the Short-Form Health Survey at baseline, 3, and 6 months after implant and compared using multivariable modeling with repeated measures. Patients with an S-ICD (n = 167) versus a TV-ICD system (n = 167) did not differ significantly on physical (p = 0.8157) and mental QoL scores (p = 0.9080) across baseline, 3, and 6 months after implantation in adjusted analyses. The evolution in physical (p = 0.0503) and mental scores (p = 0.3772) during follow-up was similar for both cohorts, as indicated by the nonsignificant interaction effect for ICD system by time. Both patients with an S-ICD system and a TV-ICD system experienced significant improvements in physical and mental QoL between time of implant and 3 months (both p's <0.0001) and between time of implant and 6 months (both p's <0.0001) but not between 3 and 6 months (both p's >0.05). In conclusion, these first results show that the QoL of patients with an S-ICD versus TV-ICD system is similar and that patients with either system experience improvements in QoL on the short term.
Boston Scientific Corporation St Paul Minnesota
Cardiology Department Russels Hall Hospital Dudley United Kingdom
Department of Cardiology Homnolka Hospital Prague Czech Republic
Department of Cardiology Odense University Hospital Odense Denmark
Department of Cardiology St Antonius Ziekenhuis Nieuwegein the Netherlands
Department of Cardiology Thorax Center Erasmus Medical Center Rotterdam the Netherlands
Department of Cardiology Thorax Center Twente Medisch Spectrum Twente Enschede the Netherlands
Department of Cardiology University Medical Center Utrecht the Netherlands
Department of Psychology University of Southern Denmark Odense Denmark
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17023880
- 003
- CZ-PrNML
- 005
- 20170830102244.0
- 007
- ta
- 008
- 170720s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.amjcard.2016.05.047 $2 doi
- 035 __
- $a (PubMed)27353211
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Pedersen, Susanne S $u Department of Psychology, University of Southern Denmark, Odense, Denmark; Department of Cardiology, Odense University Hospital, Odense, Denmark; Department of Cardiology, Thorax Center, Erasmus Medical Center, Rotterdam, the Netherlands. Electronic address: sspedersen@health.sdu.dk.
- 245 12
- $a A Comparison of the Quality of Life of Patients With an Entirely Subcutaneous Implantable Defibrillator System Versus a Transvenous System (from the EFFORTLESS S-ICD Quality of Life Substudy) / $c SS. Pedersen, MH. Mastenbroek, N. Carter, C. Barr, P. Neuzil, M. Scholten, PD. Lambiase, L. Boersma, JB. Johansen, DA. Theuns,
- 520 9_
- $a The first clinical results from the Evaluation of Factors Impacting Clinical Outcome and Cost Effectiveness of the subcutaneous implantable cardioverter defibrillator (EFFORTLESS S-ICD) Registry on the entirely S-ICD system are promising, but the impact of the S-ICD system on patients' quality of life (QoL) is not known. We evaluated the QoL of patients with an S-ICD against an unrelated cohort with a transvenous (TV)-ICD system during 6 months of follow-up. Consecutively implanted patients with an S-ICD system were matched with patients with a TV-ICD system on a priori selected variables including baseline QoL. QoL was measured with the Short-Form Health Survey at baseline, 3, and 6 months after implant and compared using multivariable modeling with repeated measures. Patients with an S-ICD (n = 167) versus a TV-ICD system (n = 167) did not differ significantly on physical (p = 0.8157) and mental QoL scores (p = 0.9080) across baseline, 3, and 6 months after implantation in adjusted analyses. The evolution in physical (p = 0.0503) and mental scores (p = 0.3772) during follow-up was similar for both cohorts, as indicated by the nonsignificant interaction effect for ICD system by time. Both patients with an S-ICD system and a TV-ICD system experienced significant improvements in physical and mental QoL between time of implant and 3 months (both p's <0.0001) and between time of implant and 6 months (both p's <0.0001) but not between 3 and 6 months (both p's >0.05). In conclusion, these first results show that the QoL of patients with an S-ICD versus TV-ICD system is similar and that patients with either system experience improvements in QoL on the short term.
- 650 _2
- $a činnosti denního života $7 D000203
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a náhlá srdeční smrt $x etiologie $x prevence a kontrola $7 D016757
- 650 12
- $a defibrilátory implantabilní $7 D017147
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a multivariační analýza $7 D015999
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a implantace protézy $x metody $7 D019919
- 650 12
- $a kvalita života $7 D011788
- 650 12
- $a registrace $7 D012042
- 650 _2
- $a komorová tachykardie $x komplikace $x terapie $7 D017180
- 650 _2
- $a fibrilace komor $x komplikace $x terapie $7 D014693
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a pozorovací studie $7 D064888
- 700 1_
- $a Mastenbroek, Mirjam H $u Department of Cardiology, University Medical Center, Utrecht, the Netherlands.
- 700 1_
- $a Carter, Nathan $u Boston Scientific Corporation, St Paul, Minnesota.
- 700 1_
- $a Barr, Craig $u Cardiology Department, Russels Hall Hospital, Dudley, United Kingdom.
- 700 1_
- $a Neuzil, Petr $u Department of Cardiology, Homnolka Hospital, Prague, Czech Republic.
- 700 1_
- $a Scholten, Marcoen $u Department of Cardiology, Thorax Center Twente, Medisch Spectrum Twente, Enschede, the Netherlands.
- 700 1_
- $a Lambiase, Pier D $u Cardiology Department, The Heart Hospital, Institute of Cardiovascular Science, University College London, London, United Kingdom.
- 700 1_
- $a Boersma, Lucas $u Department of Cardiology, St. Antonius Ziekenhuis, Nieuwegein, the Netherlands.
- 700 1_
- $a Johansen, Jens B $u Department of Cardiology, Odense University Hospital, Odense, Denmark.
- 700 1_
- $a Theuns, Dominic A M J $u Department of Cardiology, Thorax Center, Erasmus Medical Center, Rotterdam, the Netherlands.
- 773 0_
- $w MED00000236 $t The American journal of cardiology $x 1879-1913 $g Roč. 118, č. 4 (2016), s. 520-6
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27353211 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20170720 $b ABA008
- 991 __
- $a 20170830102832 $b ABA008
- 999 __
- $a ok $b bmc $g 1239561 $s 984793
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 118 $c 4 $d 520-6 $e 20160528 $i 1879-1913 $m The American journal of cardiology $n Am J Cardiol $x MED00000236
- LZP __
- $a Pubmed-20170720