Je něco špatně v tomto záznamu ?
SOFI Simulation Tool: A Software Package for Simulating and Testing Super-Resolution Optical Fluctuation Imaging
A. Girsault, T. Lukes, A. Sharipov, S. Geissbuehler, M. Leutenegger, W. Vandenberg, P. Dedecker, J. Hofkens, T. Lasser,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
Public Library of Science (PLoS)
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2006-12-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-10-01
Open Access Digital Library
od 2006-01-01
Medline Complete (EBSCOhost)
od 2008-01-01
Nursing & Allied Health Database (ProQuest)
od 2006-12-01
Health & Medicine (ProQuest)
od 2006-12-01
Public Health Database (ProQuest)
od 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
- MeSH
- algoritmy MeSH
- fluorescenční mikroskopie * MeSH
- HeLa buňky MeSH
- lidé MeSH
- počítačové zpracování obrazu metody MeSH
- software * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Super-resolution optical fluctuation imaging (SOFI) allows one to perform sub-diffraction fluorescence microscopy of living cells. By analyzing the acquired image sequence with an advanced correlation method, i.e. a high-order cross-cumulant analysis, super-resolution in all three spatial dimensions can be achieved. Here we introduce a software tool for a simple qualitative comparison of SOFI images under simulated conditions considering parameters of the microscope setup and essential properties of the biological sample. This tool incorporates SOFI and STORM algorithms, displays and describes the SOFI image processing steps in a tutorial-like fashion. Fast testing of various parameters simplifies the parameter optimization prior to experimental work. The performance of the simulation tool is demonstrated by comparing simulated results with experimentally acquired data.
Department of Chemistry University of Leuven Celestijnenlaan Heverlee Belgium
Laboratoire d'Optique Biomédicale Ecole Polytechnique Fédérale de Lausanne Lausanne Switzerland
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc17031463
- 003
- CZ-PrNML
- 005
- 20171025123016.0
- 007
- ta
- 008
- 171025s2016 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0161602 $2 doi
- 035 __
- $a (PubMed)27583365
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Girsault, Arik $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- 245 10
- $a SOFI Simulation Tool: A Software Package for Simulating and Testing Super-Resolution Optical Fluctuation Imaging / $c A. Girsault, T. Lukes, A. Sharipov, S. Geissbuehler, M. Leutenegger, W. Vandenberg, P. Dedecker, J. Hofkens, T. Lasser,
- 520 9_
- $a Super-resolution optical fluctuation imaging (SOFI) allows one to perform sub-diffraction fluorescence microscopy of living cells. By analyzing the acquired image sequence with an advanced correlation method, i.e. a high-order cross-cumulant analysis, super-resolution in all three spatial dimensions can be achieved. Here we introduce a software tool for a simple qualitative comparison of SOFI images under simulated conditions considering parameters of the microscope setup and essential properties of the biological sample. This tool incorporates SOFI and STORM algorithms, displays and describes the SOFI image processing steps in a tutorial-like fashion. Fast testing of various parameters simplifies the parameter optimization prior to experimental work. The performance of the simulation tool is demonstrated by comparing simulated results with experimentally acquired data.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a HeLa buňky $7 D006367
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 12
- $a fluorescenční mikroskopie $7 D008856
- 650 12
- $a software $7 D012984
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Lukes, Tomas $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland. Department of Radioelectronics, Faculty of Electrical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
- 700 1_
- $a Sharipov, Azat $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- 700 1_
- $a Geissbuehler, Stefan $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- 700 1_
- $a Leutenegger, Marcel $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- 700 1_
- $a Vandenberg, Wim $u Department of Chemistry, University of Leuven, Celestijnenlaan, Heverlee, Belgium.
- 700 1_
- $a Dedecker, Peter $u Department of Chemistry, University of Leuven, Celestijnenlaan, Heverlee, Belgium.
- 700 1_
- $a Hofkens, Johan $u Department of Chemistry, University of Leuven, Celestijnenlaan, Heverlee, Belgium.
- 700 1_
- $a Lasser, Theo $u Laboratoire d'Optique Biomédicale, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 11, č. 9 (2016), s. e0161602
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27583365 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20171025 $b ABA008
- 991 __
- $a 20171025123058 $b ABA008
- 999 __
- $a ok $b bmc $g 1255056 $s 992490
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 11 $c 9 $d e0161602 $e 20160901 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- LZP __
- $a Pubmed-20171025