Je něco špatně v tomto záznamu ?
Growth of a TiNb adhesion interlayer for bioactive coatings
Z. Tolde, V. Starý, L. Cvrček, M. Vandrovcová, J. Remsa, S. Daniš, J. Krčil, L. Bačáková, P. Špatenka,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
Grantová podpora
NV15-27726A
MZ0
CEP - Centrální evidence projektů
- MeSH
- adheziva MeSH
- difrakce rentgenového záření MeSH
- hydroxyapatit MeSH
- lidé MeSH
- osteoblasty MeSH
- povrchové vlastnosti MeSH
- protézy a implantáty MeSH
- slitiny chemie MeSH
- testování materiálů MeSH
- titan MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Surface bioactivity has been under intensive study with reference to its use in medical implants. Our study is focused on coatings prepared from an electroactive material which can support bone cell adhesion. Until now, hydroxyapatite films have usually been utilized as a chemically-active surface agent. However, electrically-active films could set a new direction in hard tissue replacement. As a base for these films, it is necessary to prepare an intermediate film, which can serve as a suitable barrier against the possible diffusion of some allergens and toxic elements from the substrate. The intermediate film also improves the adaptation of the mechanical properties of the basic material to an electroactive film. The aim of our work was to select an implantable and biocompatible material for this intermediate film that is suitable for coating several widely-used materials, to check the possibility of preparing an electroactive film for use on a material of this type, and to characterize the structure and several mechanical properties of this intermediate film. TiNb was selected as the material for the intermediate film, because of its excellent chemical and mechanical properties. TiNb coatings were deposited by magnetron sputtering on various substrates, namely Ti, Ti6Al4V, stainless steel, and bulk TiNb (as standard), and important properties of the layers, e.g. surface morphology and surface roughness, crystalline structure, etc., were characterized by several methods (SEM, EBSD, X-ray diffraction, nanoindentation and roughness measurement). It was found that the structure and the mechanical properties of the TiNb layer depended significantly on the type of substrate. TiNb was then used as a substrate for depositing a ferroelectrically active material, e.g., BaTiO3, and the adhesion, viability and proliferation of human osteoblast-like Saos-2 cells on this system were studied. We found that the electroactive BaTiO3 film was not only non-cytotoxic (i.e. it did not affect the cell viability). It also enhanced the growth of Saos-2 cells in comparison with pure TiNb and with standard tissue culture polystyrene wells, and also in comparison with BaTiO3 films deposited on Ti, i.e. a material clinically used for implantation into the bone.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18010353
- 003
- CZ-PrNML
- 005
- 20201019140549.0
- 007
- ta
- 008
- 180404s2017 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.msec.2017.07.013 $2 doi
- 035 __
- $a (PubMed)28866212
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Tolde, Zdeněk $u Dept. of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Karlovo Sq. 13, 121 35 Prague 2, Czech Republic.
- 245 10
- $a Growth of a TiNb adhesion interlayer for bioactive coatings / $c Z. Tolde, V. Starý, L. Cvrček, M. Vandrovcová, J. Remsa, S. Daniš, J. Krčil, L. Bačáková, P. Špatenka,
- 520 9_
- $a Surface bioactivity has been under intensive study with reference to its use in medical implants. Our study is focused on coatings prepared from an electroactive material which can support bone cell adhesion. Until now, hydroxyapatite films have usually been utilized as a chemically-active surface agent. However, electrically-active films could set a new direction in hard tissue replacement. As a base for these films, it is necessary to prepare an intermediate film, which can serve as a suitable barrier against the possible diffusion of some allergens and toxic elements from the substrate. The intermediate film also improves the adaptation of the mechanical properties of the basic material to an electroactive film. The aim of our work was to select an implantable and biocompatible material for this intermediate film that is suitable for coating several widely-used materials, to check the possibility of preparing an electroactive film for use on a material of this type, and to characterize the structure and several mechanical properties of this intermediate film. TiNb was selected as the material for the intermediate film, because of its excellent chemical and mechanical properties. TiNb coatings were deposited by magnetron sputtering on various substrates, namely Ti, Ti6Al4V, stainless steel, and bulk TiNb (as standard), and important properties of the layers, e.g. surface morphology and surface roughness, crystalline structure, etc., were characterized by several methods (SEM, EBSD, X-ray diffraction, nanoindentation and roughness measurement). It was found that the structure and the mechanical properties of the TiNb layer depended significantly on the type of substrate. TiNb was then used as a substrate for depositing a ferroelectrically active material, e.g., BaTiO3, and the adhesion, viability and proliferation of human osteoblast-like Saos-2 cells on this system were studied. We found that the electroactive BaTiO3 film was not only non-cytotoxic (i.e. it did not affect the cell viability). It also enhanced the growth of Saos-2 cells in comparison with pure TiNb and with standard tissue culture polystyrene wells, and also in comparison with BaTiO3 films deposited on Ti, i.e. a material clinically used for implantation into the bone.
- 650 _2
- $a adheziva $7 D000269
- 650 _2
- $a slitiny $x chemie $7 D000497
- 650 _2
- $a hydroxyapatit $7 D017886
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a osteoblasty $7 D010006
- 650 _2
- $a protézy a implantáty $7 D019736
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 650 _2
- $a titan $7 D014025
- 650 _2
- $a difrakce rentgenového záření $7 D014961
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Starý, Vladimír $u Dept. of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Karlovo Sq. 13, 121 35 Prague 2, Czech Republic. Electronic address: stary@fsik.cvut.cz.
- 700 1_
- $a Cvrček, Ladislav $u Dept. of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Karlovo Sq. 13, 121 35 Prague 2, Czech Republic.
- 700 1_
- $a Vandrovcová, Marta $u Dept. of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, Prague 4-Krc, Czech Republic.
- 700 1_
- $a Remsa, Jan $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Sitna Sq. 3108, 21201 Kladno, Czech Republic.
- 700 1_
- $a Daniš, Stanislav $u Dept. of Condensed Matter Physics, Faculty of Mathematics and Physics, Charles University in Prague, Ke Karlovu 5, 121 16 Prague 2, Czech Republic.
- 700 1_
- $a Krčil, Jan $u Dept. of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Karlovo Sq. 13, 121 35 Prague 2, Czech Republic.
- 700 1_
- $a Bačáková, Lucie $u Dept. of Biomaterials and Tissue Engineering, Institute of Physiology of the Czech Academy of Sciences, Videnska 1083, Prague 4-Krc, Czech Republic.
- 700 1_
- $a Špatenka, Petr $u Dept. of Materials Engineering, Faculty of Mechanical Engineering, Czech Technical University in Prague, Karlovo Sq. 13, 121 35 Prague 2, Czech Republic.
- 773 0_
- $w MED00184559 $t Materials science & engineering. C, Materials for biological applications $x 1873-0191 $g Roč. 80, č. - (2017), s. 652-658
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28866212 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180404 $b ABA008
- 991 __
- $a 20201019140549 $b ABA008
- 999 __
- $a ok $b bmc $g 1287838 $s 1007165
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 80 $c - $d 652-658 $e 20170712 $i 1873-0191 $m Materials science & engineering. C, Materials for biological applications $n Mater Sci Eng C Mater Biol Appl $x MED00184559
- GRA __
- $a NV15-27726A $p MZ0
- LZP __
- $a Pubmed-20180404