-
Je něco špatně v tomto záznamu ?
Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis
A. Procházka, M. Schätz, O. Vyšata, M. Vališ,
Jazyk angličtina Země Švýcarsko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2001
PubMed Central
od 2003
Europe PubMed Central
od 2003
ProQuest Central
od 2001-01-01
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2003-01-01
Health & Medicine (ProQuest)
od 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
27367687
DOI
10.3390/s16070996
Knihovny.cz E-zdroje
- MeSH
- audiovizuální záznam MeSH
- časové faktory MeSH
- dýchání * MeSH
- lidé MeSH
- monitorování fyziologických funkcí přístrojové vybavení MeSH
- pohyb MeSH
- srdeční frekvence fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
This paper is devoted to a new method of using Microsoft (MS) Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and infrared sensors to enable their time analysis in selected regions of interest. The proposed methodology includes the use of computational methods and functional transforms for data selection, as well as their denoising, spectral analysis and visualization, in order to determine specific biomedical features. The results that were obtained verify the correspondence between the evaluation of the breathing frequency that was obtained from the image and infrared data of the mouth area and from the thorax movement that was recorded by the depth sensor. Spectral analysis of the time evolution of the mouth area video frames was also used for heart rate estimation. Results estimated from the image and infrared data of the mouth area were compared with those obtained by contact measurements by Garmin sensors (www.garmin.com). The study proves that simple image and depth sensors can be used to efficiently record biomedical multidimensional data with sufficient accuracy to detect selected biomedical features using specific methods of computational intelligence. The achieved accuracy for non-contact detection of breathing rate was 0.26% and the accuracy of heart rate estimation was 1.47% for the infrared sensor. The following results show how video frames with depth data can be used to differentiate different kinds of breathing. The proposed method enables us to obtain and analyse data for diagnostic purposes in the home environment or during physical activities, enabling efficient human-machine interaction.
Charles University 500 05 Hradec Kr and 225
Department of Neurology Faculty of Medicine in Hradec Kr and 225
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18011135
- 003
- CZ-PrNML
- 005
- 20180417111816.0
- 007
- ta
- 008
- 180404s2016 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s16070996 $2 doi
- 035 __
- $a (PubMed)27367687
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Procházka, Aleš $u Department of Computing and Control Engineering, University of Chemistry and Technology, 166 28 Prague 6, Czech Republic. A.Prochazka@ieee.org.
- 245 10
- $a Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis / $c A. Procházka, M. Schätz, O. Vyšata, M. Vališ,
- 520 9_
- $a This paper is devoted to a new method of using Microsoft (MS) Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and infrared sensors to enable their time analysis in selected regions of interest. The proposed methodology includes the use of computational methods and functional transforms for data selection, as well as their denoising, spectral analysis and visualization, in order to determine specific biomedical features. The results that were obtained verify the correspondence between the evaluation of the breathing frequency that was obtained from the image and infrared data of the mouth area and from the thorax movement that was recorded by the depth sensor. Spectral analysis of the time evolution of the mouth area video frames was also used for heart rate estimation. Results estimated from the image and infrared data of the mouth area were compared with those obtained by contact measurements by Garmin sensors (www.garmin.com). The study proves that simple image and depth sensors can be used to efficiently record biomedical multidimensional data with sufficient accuracy to detect selected biomedical features using specific methods of computational intelligence. The achieved accuracy for non-contact detection of breathing rate was 0.26% and the accuracy of heart rate estimation was 1.47% for the infrared sensor. The following results show how video frames with depth data can be used to differentiate different kinds of breathing. The proposed method enables us to obtain and analyse data for diagnostic purposes in the home environment or during physical activities, enabling efficient human-machine interaction.
- 650 _2
- $a srdeční frekvence $x fyziologie $7 D006339
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a monitorování fyziologických funkcí $x přístrojové vybavení $7 D008991
- 650 _2
- $a pohyb $7 D009068
- 650 12
- $a dýchání $7 D012119
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a audiovizuální záznam $7 D014741
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Schätz, Martin $u Department of Computing and Control Engineering, University of Chemistry and Technology, 166 28 Prague 6, Czech Republic. Martin.Schatz@vscht.cz.
- 700 1_
- $a Vyšata, Oldřich $u Department of Computing and Control Engineering, University of Chemistry and Technology, 166 28 Prague 6, Czech Republic. Vysatao@gmail.com. Czech Institute of Informatics, Robotics and Cybernetics, Czech Technical University, 166 36 Prague 6, Czech Republic. Vysatao@gmail.com. Department of Neurology, Faculty of Medicine in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech Republic. Vysatao@gmail.com.
- 700 1_
- $a Vališ, Martin $u Department of Neurology, Faculty of Medicine in Hradec Králové, Charles University, 500 05 Hradec Králové, Czech Republic. Valismar@seznam.cz.
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 16, č. 7 (2016)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/27367687 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180404 $b ABA008
- 991 __
- $a 20180417111914 $b ABA008
- 999 __
- $a ok $b bmc $g 1288620 $s 1007947
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2016 $b 16 $c 7 $e 20160628 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- LZP __
- $a Pubmed-20180404