Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation

P. Osmancik, P. Budera, J. Zdarska, D. Herman, R. Petr, Z. Straka,

. 2016 ; 13 (6) : 1246-52. [pub] 20160215

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc18011289

BACKGROUND: Hybrid ablation (a combination of thoracoscopic epicardial ablation and catheter ablation) has become a new technique for atrial fibrillation treatment. OBJECTIVE: The goal of this study was to evaluate the success and electrophysiological follow-up after using the COBRA Fusion device to deliver a circumferential lesion set anterior to the pulmonary veins in an attempt to isolate the posterior left atrium (box isolation). METHODS: Surgical ablation was carried out via a thoracoscopic approach using the COBRA Fusion radiofrequency catheter. An electrophysiology study was done 2-3 months later to verify box isolation (and to complete it, if needed) and to perform right-sided isthmus ablation. Fat thickness along the presumed box lesion line was measured using preprocedural computed tomography. RESULTS: Thirty patients (mean age 60.0 ± 11.6 years; 22 men; 8 with long-standing persistent AF and 22 with persistent atrial fibrillation) were enrolled. The duration of the EP study was 216.3 ± 64.2 minutes. Box isolation, based on the EP study, was complete in 12 patients (40%) and incomplete in 18 patients (60%). Successful box isolation was achieved with catheter ablation in 16 of 18 patients (89%). A total of 39 gaps in these 16 patients were identified. Typical gap locations were the anterior-superior part of the superior pulmonary veins and the roofline. Fat thickness along the roofline was substantially higher than that along the inferior line (4.58 ± 1.61 mm vs 2.37 ± 0.76 mm; P < .001). CONCLUSION: There is a relatively low rate of complete isolation using the COBRA catheter ablation system. The superior line and anterior parts of superior pulmonary veins have most conduction gaps.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18011289
003      
CZ-PrNML
005      
20180404142715.0
007      
ta
008      
180404s2016 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.hrthm.2016.02.007 $2 doi
035    __
$a (PubMed)26892466
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Osmancik, Pavel $u IIIrd Internal - Cardiology Clinic. Electronic address: pavel.osmancik@gmail.com.
245    10
$a Electrophysiological findings after surgical thoracoscopic atrial fibrillation ablation / $c P. Osmancik, P. Budera, J. Zdarska, D. Herman, R. Petr, Z. Straka,
520    9_
$a BACKGROUND: Hybrid ablation (a combination of thoracoscopic epicardial ablation and catheter ablation) has become a new technique for atrial fibrillation treatment. OBJECTIVE: The goal of this study was to evaluate the success and electrophysiological follow-up after using the COBRA Fusion device to deliver a circumferential lesion set anterior to the pulmonary veins in an attempt to isolate the posterior left atrium (box isolation). METHODS: Surgical ablation was carried out via a thoracoscopic approach using the COBRA Fusion radiofrequency catheter. An electrophysiology study was done 2-3 months later to verify box isolation (and to complete it, if needed) and to perform right-sided isthmus ablation. Fat thickness along the presumed box lesion line was measured using preprocedural computed tomography. RESULTS: Thirty patients (mean age 60.0 ± 11.6 years; 22 men; 8 with long-standing persistent AF and 22 with persistent atrial fibrillation) were enrolled. The duration of the EP study was 216.3 ± 64.2 minutes. Box isolation, based on the EP study, was complete in 12 patients (40%) and incomplete in 18 patients (60%). Successful box isolation was achieved with catheter ablation in 16 of 18 patients (89%). A total of 39 gaps in these 16 patients were identified. Typical gap locations were the anterior-superior part of the superior pulmonary veins and the roofline. Fat thickness along the roofline was substantially higher than that along the inferior line (4.58 ± 1.61 mm vs 2.37 ± 0.76 mm; P < .001). CONCLUSION: There is a relatively low rate of complete isolation using the COBRA catheter ablation system. The superior line and anterior parts of superior pulmonary veins have most conduction gaps.
650    _2
$a senioři $7 D000368
650    _2
$a fibrilace síní $x diagnóza $x patofyziologie $x chirurgie $7 D001281
650    _2
$a katetrizační ablace $x metody $7 D017115
650    _2
$a elektrofyziologické techniky kardiologické $x metody $7 D022062
650    _2
$a následné studie $7 D005500
650    _2
$a převodní systém srdeční $x patofyziologie $7 D006329
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a venae pulmonales $x chirurgie $7 D011667
650    _2
$a torakoskopie $x metody $7 D013906
650    _2
$a časové faktory $7 D013997
650    _2
$a výsledek terapie $7 D016896
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Budera, Petr $u Clinic of Cardiac Surgery, University Hospital Kralovske Vinohrady, Charles University, Prague, Czech Republic.
700    1_
$a Zdarska, Jana $u IIIrd Internal - Cardiology Clinic.
700    1_
$a Herman, Dalibor $u IIIrd Internal - Cardiology Clinic.
700    1_
$a Petr, Robert $u IIIrd Internal - Cardiology Clinic.
700    1_
$a Straka, Zbynek $u Clinic of Cardiac Surgery, University Hospital Kralovske Vinohrady, Charles University, Prague, Czech Republic.
773    0_
$w MED00156180 $t Heart rhythm $x 1556-3871 $g Roč. 13, č. 6 (2016), s. 1246-52
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26892466 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180404 $b ABA008
991    __
$a 20180404142754 $b ABA008
999    __
$a ok $b bmc $g 1288774 $s 1008101
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2016 $b 13 $c 6 $d 1246-52 $e 20160215 $i 1556-3871 $m Heart rhythm $n Heart Rhythm $x MED00156180
LZP    __
$a Pubmed-20180404

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...