-
Something wrong with this record ?
Functional gold nanoparticles for optical affinity biosensing
T. Špringer, X. Chadtová Song, ML. Ermini, J. Lamačová, J. Homola,
Language English Country Germany
Document type Evaluation Study, Journal Article
NLK
ProQuest Central
from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2011-01-01 to 1 year ago
- MeSH
- Antibodies, Immobilized chemistry MeSH
- Carcinoembryonic Antigen analysis blood MeSH
- Hydrogen-Ion Concentration MeSH
- Metal Nanoparticles chemistry MeSH
- Humans MeSH
- Limit of Detection MeSH
- Surface Plasmon Resonance methods MeSH
- Buffers MeSH
- Gold chemistry MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
Functional gold nanoparticles (AuNPs) are commonly used to enhance the response of optical affinity biosensors. In this work, we investigated the effect of preparation conditions on functional properties of AuNPs functionalized with antibody (Ab-AuNPs), specifically AuNPs with antibody against carcinoembryonic antigen (CEA) covalently attached via carboxy-terminated oligo-ethylene thiolate linker layer. The following parameters of preparation of Ab-AuNP have been found to have a significant effect on Ab-AuNP performance in affinity biosensors: the time of reaction of activated AuNPs with antibody, concentrations of antibody and amino-coupling reagents, and composition of immobilization buffer (molarity and salt content). In contrast, pH of immobilization buffer has been demonstrated to have only a minor influence. Our experiments showed that the Ab-AuNPs prepared under optimum conditions offered a binding efficiency of Ab-AuNPs to CEA as high as 63%, which is more than 4 times better than the best efficiencies reported for similar functional AuNPs so far. We employed these Ab-AuNPs with a surface plasmon resonance (SPR) biosensor for the detection of CEA and showed that the Ab-AuNPs enhanced the sensor response to CEA by a factor of 1000. We also demonstrated that the Ab-AuNPs allow the biosensor to detect CEA at concentrations as low as 12 and 40 pg/mL in buffer and 50% blood plasma, respectively.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18025080
- 003
- CZ-PrNML
- 005
- 20180710095128.0
- 007
- ta
- 008
- 180709s2017 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-017-0355-1 $2 doi
- 035 __
- $a (PubMed)28417176
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Špringer, Tomáš $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic. springer@ufe.cz.
- 245 10
- $a Functional gold nanoparticles for optical affinity biosensing / $c T. Špringer, X. Chadtová Song, ML. Ermini, J. Lamačová, J. Homola,
- 520 9_
- $a Functional gold nanoparticles (AuNPs) are commonly used to enhance the response of optical affinity biosensors. In this work, we investigated the effect of preparation conditions on functional properties of AuNPs functionalized with antibody (Ab-AuNPs), specifically AuNPs with antibody against carcinoembryonic antigen (CEA) covalently attached via carboxy-terminated oligo-ethylene thiolate linker layer. The following parameters of preparation of Ab-AuNP have been found to have a significant effect on Ab-AuNP performance in affinity biosensors: the time of reaction of activated AuNPs with antibody, concentrations of antibody and amino-coupling reagents, and composition of immobilization buffer (molarity and salt content). In contrast, pH of immobilization buffer has been demonstrated to have only a minor influence. Our experiments showed that the Ab-AuNPs prepared under optimum conditions offered a binding efficiency of Ab-AuNPs to CEA as high as 63%, which is more than 4 times better than the best efficiencies reported for similar functional AuNPs so far. We employed these Ab-AuNPs with a surface plasmon resonance (SPR) biosensor for the detection of CEA and showed that the Ab-AuNPs enhanced the sensor response to CEA by a factor of 1000. We also demonstrated that the Ab-AuNPs allow the biosensor to detect CEA at concentrations as low as 12 and 40 pg/mL in buffer and 50% blood plasma, respectively.
- 650 _2
- $a imobilizační protilátky $x chemie $7 D055910
- 650 _2
- $a pufry $7 D002021
- 650 _2
- $a karcinoembryonální antigen $x analýza $x krev $7 D002272
- 650 _2
- $a zlato $x chemie $7 D006046
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a kovové nanočástice $x chemie $7 D053768
- 650 _2
- $a povrchová plasmonová rezonance $x metody $7 D020349
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Chadtová Song, Xue $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
- 700 1_
- $a Ermini, Maria Laura $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
- 700 1_
- $a Lamačová, Josefína $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
- 700 1_
- $a Homola, Jiří $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic. homola@ufe.cz.
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 409, č. 16 (2017), s. 4087-4097
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28417176 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20180709 $b ABA008
- 991 __
- $a 20180710095418 $b ABA008
- 999 __
- $a ok $b bmc $g 1317211 $s 1022001
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 409 $c 16 $d 4087-4097 $e 20170417 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20180709