Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Functional gold nanoparticles for optical affinity biosensing

T. Špringer, X. Chadtová Song, ML. Ermini, J. Lamačová, J. Homola,

. 2017 ; 409 (16) : 4087-4097. [pub] 20170417

Language English Country Germany

Document type Evaluation Study, Journal Article

E-resources Online Full text

NLK ProQuest Central from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost) from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest) from 2011-01-01 to 1 year ago

Functional gold nanoparticles (AuNPs) are commonly used to enhance the response of optical affinity biosensors. In this work, we investigated the effect of preparation conditions on functional properties of AuNPs functionalized with antibody (Ab-AuNPs), specifically AuNPs with antibody against carcinoembryonic antigen (CEA) covalently attached via carboxy-terminated oligo-ethylene thiolate linker layer. The following parameters of preparation of Ab-AuNP have been found to have a significant effect on Ab-AuNP performance in affinity biosensors: the time of reaction of activated AuNPs with antibody, concentrations of antibody and amino-coupling reagents, and composition of immobilization buffer (molarity and salt content). In contrast, pH of immobilization buffer has been demonstrated to have only a minor influence. Our experiments showed that the Ab-AuNPs prepared under optimum conditions offered a binding efficiency of Ab-AuNPs to CEA as high as 63%, which is more than 4 times better than the best efficiencies reported for similar functional AuNPs so far. We employed these Ab-AuNPs with a surface plasmon resonance (SPR) biosensor for the detection of CEA and showed that the Ab-AuNPs enhanced the sensor response to CEA by a factor of 1000. We also demonstrated that the Ab-AuNPs allow the biosensor to detect CEA at concentrations as low as 12 and 40 pg/mL in buffer and 50% blood plasma, respectively.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18025080
003      
CZ-PrNML
005      
20180710095128.0
007      
ta
008      
180709s2017 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-017-0355-1 $2 doi
035    __
$a (PubMed)28417176
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Špringer, Tomáš $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic. springer@ufe.cz.
245    10
$a Functional gold nanoparticles for optical affinity biosensing / $c T. Špringer, X. Chadtová Song, ML. Ermini, J. Lamačová, J. Homola,
520    9_
$a Functional gold nanoparticles (AuNPs) are commonly used to enhance the response of optical affinity biosensors. In this work, we investigated the effect of preparation conditions on functional properties of AuNPs functionalized with antibody (Ab-AuNPs), specifically AuNPs with antibody against carcinoembryonic antigen (CEA) covalently attached via carboxy-terminated oligo-ethylene thiolate linker layer. The following parameters of preparation of Ab-AuNP have been found to have a significant effect on Ab-AuNP performance in affinity biosensors: the time of reaction of activated AuNPs with antibody, concentrations of antibody and amino-coupling reagents, and composition of immobilization buffer (molarity and salt content). In contrast, pH of immobilization buffer has been demonstrated to have only a minor influence. Our experiments showed that the Ab-AuNPs prepared under optimum conditions offered a binding efficiency of Ab-AuNPs to CEA as high as 63%, which is more than 4 times better than the best efficiencies reported for similar functional AuNPs so far. We employed these Ab-AuNPs with a surface plasmon resonance (SPR) biosensor for the detection of CEA and showed that the Ab-AuNPs enhanced the sensor response to CEA by a factor of 1000. We also demonstrated that the Ab-AuNPs allow the biosensor to detect CEA at concentrations as low as 12 and 40 pg/mL in buffer and 50% blood plasma, respectively.
650    _2
$a imobilizační protilátky $x chemie $7 D055910
650    _2
$a pufry $7 D002021
650    _2
$a karcinoembryonální antigen $x analýza $x krev $7 D002272
650    _2
$a zlato $x chemie $7 D006046
650    _2
$a lidé $7 D006801
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a limita detekce $7 D057230
650    _2
$a kovové nanočástice $x chemie $7 D053768
650    _2
$a povrchová plasmonová rezonance $x metody $7 D020349
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
700    1_
$a Chadtová Song, Xue $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
700    1_
$a Ermini, Maria Laura $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
700    1_
$a Lamačová, Josefína $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic.
700    1_
$a Homola, Jiří $u Institute of Photonics and Electronics, Czech Academy of Sciences, Chaberská 57, Prague, Czech Republic. homola@ufe.cz.
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 409, č. 16 (2017), s. 4087-4097
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28417176 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20180710095418 $b ABA008
999    __
$a ok $b bmc $g 1317211 $s 1022001
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 409 $c 16 $d 4087-4097 $e 20170417 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
LZP    __
$a Pubmed-20180709

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...