Analysis of selected designer benzodiazepines by ultra high performance liquid chromatography with high-resolution time-of-flight mass spectrometry and the estimation of their partition coefficients by micellar electrokinetic chromatography

J. Tomková, M. Švidrnoch, V. Maier, P. Ondra,

. 2017 ; 40 (9) : 2037-2044. [pub] 20170410

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc18025134

A new ultra high performance liquid chromatography with electrospray ionization time of flight mass spectrometry method for the selective and sensitive separation, identification, and determination of selected designer benzodiazepines (namely, pyrazolam, phenazepam, etizolam, flubromazepam, diclazepam, deschloroetizolam, bentazepam, nimetazepam, and flubromazolam) in human serum was developed. The separation of the studied designer benzodiazepines was achieved on C18 chromatographic column using gradient elution within 6 min without any significant matrix interferences. Liquid-liquid extraction with butyl acetate was applied for serum samples cleanup and preconcentration of studied designer benzodiazepines. The method was validated in terms of linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery, and sample stability. The limit of detection values were 0.10-0.15 ng/mL. The method was applied to a spiked serum sample to demonstrate its applicability for systematic toxicology analysis. Furthermore, a capillary chromatographic method with micellar electrokinetic chromatography was used for the estimation of partition coefficients of studied designer benzodiazepines as important parameters to evaluate their pharmacological and toxicological properties.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18025134
003      
CZ-PrNML
005      
20180710095120.0
007      
ta
008      
180709s2017 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201700069 $2 doi
035    __
$a (PubMed)28266783
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Tomková, Jana $u Department of Forensic Medicine and Medical Law, Faculty Hospital, Olomouc, Czech Republic.
245    10
$a Analysis of selected designer benzodiazepines by ultra high performance liquid chromatography with high-resolution time-of-flight mass spectrometry and the estimation of their partition coefficients by micellar electrokinetic chromatography / $c J. Tomková, M. Švidrnoch, V. Maier, P. Ondra,
520    9_
$a A new ultra high performance liquid chromatography with electrospray ionization time of flight mass spectrometry method for the selective and sensitive separation, identification, and determination of selected designer benzodiazepines (namely, pyrazolam, phenazepam, etizolam, flubromazepam, diclazepam, deschloroetizolam, bentazepam, nimetazepam, and flubromazolam) in human serum was developed. The separation of the studied designer benzodiazepines was achieved on C18 chromatographic column using gradient elution within 6 min without any significant matrix interferences. Liquid-liquid extraction with butyl acetate was applied for serum samples cleanup and preconcentration of studied designer benzodiazepines. The method was validated in terms of linearity, limit of detection, limit of quantification, matrix effects, specificity, precision, accuracy, recovery, and sample stability. The limit of detection values were 0.10-0.15 ng/mL. The method was applied to a spiked serum sample to demonstrate its applicability for systematic toxicology analysis. Furthermore, a capillary chromatographic method with micellar electrokinetic chromatography was used for the estimation of partition coefficients of studied designer benzodiazepines as important parameters to evaluate their pharmacological and toxicological properties.
650    _2
$a benzodiazepiny $x krev $7 D001569
650    12
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a lidé $7 D006801
650    _2
$a limita detekce $7 D057230
650    _2
$a micely $7 D008823
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    12
$a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
655    _2
$a časopisecké články $7 D016428
700    1_
$a Švidrnoch, Martin $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacky University in Olomouc, Olomouc, Czech Republic.
700    1_
$a Maier, Vítězslav $u Department of Analytical Chemistry, Regional Centre of Advanced Technologies and Materials, Faculty of Science, Palacky University in Olomouc, Olomouc, Czech Republic.
700    1_
$a Ondra, Peter $u Department of Forensic Medicine and Medical Law, Faculty Hospital, Olomouc, Czech Republic.
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 40, č. 9 (2017), s. 2037-2044
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28266783 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20180709 $b ABA008
991    __
$a 20180710095410 $b ABA008
999    __
$a ok $b bmc $g 1317265 $s 1022055
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 40 $c 9 $d 2037-2044 $e 20170410 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$a Pubmed-20180709

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...