The objective of this study was to develop and validate a novel analytical procedure for determination of total chromium and Cr(III) and Cr(VI) species released from metal implants into whole blood and joint effusion. Firstly, the ion-pair chromatographic method employing reversed-phase high-performance liquid chromatography inductively coupled plasma mass spectrometry (ICP-MS) for analysis of species was developed. Secondly, all samples, protein and low molecular fractions were analyzed for their total chromium content using ICP-MS. This new measurement procedure was validated by the following parameters: limit of detection (0.13 μg L-1 for Cr(III), 0.14 μg L-1 for Cr(VI)), linearity of calibration, trueness (recovery 84-92%), intermediate precision (RSD < 5%). We determined statistically significantly higher chromium levels in joint effusion samples obtained from patients in comparison with a control group. On the other hand, no relevant difference among the concentrations of both species and total chromium in blood was observed. Our results show that the majority of chromium is present in the trivalent form and bound to proteins. This speciation study is rare in the field of speciation analysis in clinical samples. It is characterized by very fast and simple sample preparation without any changes in distribution or stability of both Cr forms and efficient simultaneous analysis of Cr species.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18033087
- 003
- CZ-PrNML
- 005
- 20220328110606.0
- 007
- ta
- 008
- 181008s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2018.03.100 $2 doi
- 035 __
- $a (PubMed)29759215
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Pechancová, Radka $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17,listopadu 12, 771 46 Olomouc, Czech Republic.
- 245 10
- $a Study of chromium species release from metal implants in blood and joint effusion: Utilization of HPLC-ICP-MS / $c R. Pechancová, T. Pluháček, J. Gallo, D. Milde,
- 520 9_
- $a The objective of this study was to develop and validate a novel analytical procedure for determination of total chromium and Cr(III) and Cr(VI) species released from metal implants into whole blood and joint effusion. Firstly, the ion-pair chromatographic method employing reversed-phase high-performance liquid chromatography inductively coupled plasma mass spectrometry (ICP-MS) for analysis of species was developed. Secondly, all samples, protein and low molecular fractions were analyzed for their total chromium content using ICP-MS. This new measurement procedure was validated by the following parameters: limit of detection (0.13 μg L-1 for Cr(III), 0.14 μg L-1 for Cr(VI)), linearity of calibration, trueness (recovery 84-92%), intermediate precision (RSD < 5%). We determined statistically significantly higher chromium levels in joint effusion samples obtained from patients in comparison with a control group. On the other hand, no relevant difference among the concentrations of both species and total chromium in blood was observed. Our results show that the majority of chromium is present in the trivalent form and bound to proteins. This speciation study is rare in the field of speciation analysis in clinical samples. It is characterized by very fast and simple sample preparation without any changes in distribution or stability of both Cr forms and efficient simultaneous analysis of Cr species.
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 _2
- $a chrom $x analýza $7 D002857
- 650 12
- $a zubní implantáty $7 D015921
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a kolenní kloub $x chemie $7 D007719
- 650 _2
- $a hmotnostní spektrometrie $7 D013058
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Pluháček, Tomáš $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17,listopadu 12, 771 46 Olomouc, Czech Republic.
- 700 1_
- $a Gallo, Jiří $u Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacký University Olomouc, University Hospital Olomouc, I. P. Pavlova 6, 77520 Olomouc, Czech Republic.
- 700 1_
- $a Milde, David, $u Regional Centre of Advanced Technologies and Materials, Department of Analytical Chemistry, Faculty of Science, Palacký University in Olomouc, 17,listopadu 12, 771 46 Olomouc, Czech Republic. Electronic address: david.milde@upol.cz. $d 1973- $7 ola2002157911
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 185, č. - (2018), s. 370-377
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29759215 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20220328110604 $b ABA008
- 999 __
- $a ok $b bmc $g 1339365 $s 1030081
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 185 $c - $d 370-377 $e 20180330 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- GRA __
- $a NV16-31852A $p MZ0
- LZP __
- $a Pubmed-20181008