Stainless steel welders are exposed to heavy filler metals. We evaluated the concentration of these metals in whole blood and urine, and the relevant biochemical parameters in relation to the total chromosomal aberrations (CAs), chromatid-type (CTA-type, CTAs) and chromosome-type (CSA-type, CSAs), in 117 welders and control individuals. Statistically higher concentrations of the total Cr, Ni and Mn were observed in whole blood and urine of welders, and the concentrations were higher in welders who smoked. On the contrary, concentrations of urinary heavy metals Cr and Mn adjusted for creatinine were significantly higher in the control groups. A statistically higher frequency of total CAs was observed in the whole group of welders, and also in the non-smoking welders, as compared to controls. The frequency of total CAs significantly correlated with the concentration of Cr, Ni and Mn in whole blood (R=0.61, P˂0.0001, R=0.33, P˂0.0001 and R=0.66, P˂0.0001, respectively), with urinary concentrations of Ni and Mn (R=0.27, P=0.003 and R=0.28, P=0.003, respectively) and with urinary concentrations of Cr, Ni and Mn adjusted for creatinine (R=0.22, P=0.029, R=0.26, P=0.005 and R=0.20, P=0.030, respectively). Likewise, the frequency of CTA-types significantly correlated with the concentration of Cr and Mn in whole blood (R=0.31, P=0.0007 and R=0.34, P=0.0002). The frequency of CSA-types significantly correlated with concentrations of Cr, Ni and Mn in whole blood (R=0.43, P˂0.0001, R=0.38, P˂0.0001 and R=0.46, P˂0.0001, respectively). The statistically higher values of serum creatinine and total bilirubin were detected in all welders, as well as in smokers when compared to the corresponding controls. The exposure to heavy metals in welders increased the frequencies of CAs and altered the balance between urinary excretion of heavy metals and their possible accumulation.
- MeSH
- chrom moč krev MeSH
- chromozomální aberace * chemicky indukované MeSH
- dospělí MeSH
- kouření škodlivé účinky moč krev MeSH
- kreatinin moč krev MeSH
- lidé středního věku MeSH
- lidé MeSH
- mangan moč krev MeSH
- nerezavějící ocel MeSH
- nikl moč krev MeSH
- pracovní expozice * škodlivé účinky analýza MeSH
- studie případů a kontrol MeSH
- svařování * MeSH
- těžké kovy * moč krev MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
The aim of the current study was to screen and identify heavy metal (chromium, cadmium, and lead) associated bacteria from petroleum-contaminated soil of district Muzaffarabad, Azad Jammu and Kashmir, Pakistan to develop ecofriendly technology for contaminated soil remediation. The petroleum-contaminated soil was collected from 99 different localities of district Muzaffarabad and the detection of heavy metals via an atomic absorption spectrometer. The isolation and identification of heavy metals-associated bacteria were done via traditional and molecular methods. Resistogram and antibiogram analysis were also performed using agar well diffusion and agar disc diffusion methods. The isolated bacteria were classified into species, i.e., B. paramycoides, B. albus, B. thuringiensis, B. velezensis, B. anthracis, B. pacificus Burkholderia arboris, Burkholderia reimsis, Burkholderia aenigmatica, and Streptococcus agalactiae. All heavy metals-associated bacteria showed resistance against both high and low concentrations of chromium while sensitive towards high and low concentrations of lead in the range of 3.0 ± 0.0 mm to 13.0 ± 0.0 mm and maximum inhibition was recorded when cadmium was used. Results revealed that some bacteria showed sensitivity towards Sulphonamides, Norfloxacin, Erythromycin, and Tobramycin. It was concluded that chromium-resistant bacteria could be used as a favorable source for chromium remediation from contaminated areas and could be used as a potential microbial filter.
- MeSH
- antibakteriální látky * farmakologie MeSH
- Bacteria * účinky léků klasifikace izolace a purifikace genetika MeSH
- chrom metabolismus MeSH
- kadmium analýza MeSH
- látky znečišťující půdu * analýza MeSH
- mikrobiální testy citlivosti * MeSH
- olovo MeSH
- půda chemie MeSH
- půdní mikrobiologie * MeSH
- ropa mikrobiologie analýza MeSH
- těžké kovy * farmakologie analýza MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Pákistán MeSH
BACKGROUND: While much research has been done to identify individual workplace lung carcinogens, little is known about joint effects on risk when workers are exposed to multiple agents. OBJECTIVES: We investigated the pairwise joint effects of occupational exposures to asbestos, respirable crystalline silica, metals (i.e., nickel, chromium-VI), and polycyclic aromatic hydrocarbons (PAH) on lung cancer risk, overall and by major histologic subtype, while accounting for cigarette smoking. METHODS: In the international 14-center SYNERGY project, occupational exposures were assigned to 16,901 lung cancer cases and 20,965 control subjects using a quantitative job-exposure matrix (SYN-JEM). Odds ratios (ORs) and 95% confidence intervals (CIs) were computed for ever vs. never exposure using logistic regression models stratified by sex and adjusted for study center, age, and smoking habits. Joint effects among pairs of agents were assessed on multiplicative and additive scales, the latter by calculating the relative excess risk due to interaction (RERI). RESULTS: All pairwise joint effects of lung carcinogens in men were associated with an increased risk of lung cancer. However, asbestos/metals and metals/PAH resulted in less than additive effects; while the chromium-VI/silica pair showed marginally synergistic effect in relation to adenocarcinoma (RERI: 0.24; CI: 0.02, 0.46; p = 0.05). In women, several pairwise joint effects were observed for small cell lung cancer including exposure to PAH/silica (OR = 5.12; CI: 1.77, 8.48), and to asbestos/silica (OR = 4.32; CI: 1.35, 7.29), where exposure to PAH/silica resulted in a synergistic effect (RERI: 3.45; CI: 0.10, 6.8). DISCUSSION: Small or no deviation from additive or multiplicative effects was observed, but co-exposure to the selected lung carcinogens resulted generally in higher risk than exposure to individual agents, highlighting the importance to reduce and control exposure to carcinogens in workplaces and the general environment. https://doi.org/10.1289/EHP13380.
- MeSH
- azbest * toxicita MeSH
- chrom toxicita MeSH
- karcinogeny toxicita MeSH
- lidé MeSH
- nádory plic * chemicky indukované epidemiologie MeSH
- oxid křemičitý toxicita MeSH
- plíce MeSH
- polycyklické aromatické uhlovodíky * toxicita MeSH
- pracovní expozice * MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
There is limited evidence regarding the exposure-effect relationship between lung-cancer risk and hexavalent chromium (Cr(VI)) or nickel. We estimated lung-cancer risks in relation to quantitative indices of occupational exposure to Cr(VI) and nickel and their interaction with smoking habits. We pooled 14 case-control studies from Europe and Canada, including 16 901 lung-cancer cases and 20 965 control subjects. A measurement-based job-exposure-matrix estimated job-year-region specific exposure levels to Cr(VI) and nickel, which were linked to the subjects' occupational histories. Odds ratios (OR) and associated 95% confidence intervals (CI) were calculated by unconditional logistic regression, adjusting for study, age group, smoking habits and exposure to other occupational lung carcinogens. Due to their high correlation, we refrained from mutually adjusting for Cr(VI) and nickel independently. In men, ORs for the highest quartile of cumulative exposure to CR(VI) were 1.32 (95% CI 1.19-1.47) and 1.29 (95% CI 1.15-1.45) in relation to nickel. Analogous results among women were: 1.04 (95% CI 0.48-2.24) and 1.29 (95% CI 0.60-2.86), respectively. In men, excess lung-cancer risks due to occupational Cr(VI) and nickel exposure were also observed in each stratum of never, former and current smokers. Joint effects of Cr(VI) and nickel with smoking were in general greater than additive, but not different from multiplicative. In summary, relatively low cumulative levels of occupational exposure to Cr(VI) and nickel were associated with increased ORs for lung cancer, particularly in men. However, we cannot rule out a combined classical measurement and Berkson-type of error structure, which may cause differential bias of risk estimates.
- MeSH
- chrom toxicita analýza MeSH
- lidé MeSH
- nádory plic * chemicky indukované epidemiologie MeSH
- nikl toxicita analýza MeSH
- pracovní expozice * škodlivé účinky analýza MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
This unique study provides information on Cr species and their distribution in periprosthetic tissues of patients with metal-on-polyethylene joint implants. Co-Cr-Mo alloy has been widely used in joint replacement and represents a source of metal derived species. In the case of chromium, previous studies on periprosthetic tissues revealed mainly Cr(III) distribution, whereas the potential release of carcinogenic Cr(VI) species has been still a subject of debate. Here, an analytical approach utilizing speciation and fractionation was developed to analyze periprosthetic tissue samples collected from wide range of patients with failed total hip or knee replacements. The results reveal that Cr(III) is mainly released in the form of insoluble CrPO4 and Cr2 O3 particles. The highest Cr contents were found in periprosthetic tissues of patients suffering from aseptic loosening and having more Cr-based implants in the body. Cr species penetrated tissue layers, but their levels decreased with the distance from an implant. The detailed speciation/fractionation study carried out using the set of consecutive periprosthetic tissues of a patient with extensive metallosis showed the presence of trace amounts of free Cr(III), nanoparticles, and metal-protein complexes, but the majority of Cr still occurred in CrPO4 form. Carcinogenic Cr(VI) species were not detected. Up to date, there is no published human tissue study focused on the detailed speciation of both soluble and insoluble Cr-based species in the context of failing total hip and knee replacements.
- MeSH
- chrom MeSH
- kovy MeSH
- kyčelní protézy * MeSH
- lidé MeSH
- náhrada kyčelního kloubu * MeSH
- selhání protézy MeSH
- totální endoprotéza kolene * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The pan-European human biomonitoring initiative HBM4EU targets the harmonization of human biomonitoring (HBM) procedures and data for both environmental and occupational exposure, including chromium. The determination of chromium in urine (U-Cr), plasma (P-Cr) and whole blood (WB-Cr) is a common HBM application in employees occupationally exposed to chromium (VI) compounds. METHODS: European laboratories which have registered as candidate laboratories for chromium analysis within HBM4EU were invited to participate in a quality assurance/qualitycontrol (QA/QC) programme comprising interlaboratory comparison investigations (ICI) for the parameters U-Cr, P-Cr and WB-Cr. Participating laboratories received two samples of different concentrations in each of four rounds and were asked to analyse the samples using their standard analytical procedure. The data were evaluated by the Z-score approach and were reported to the participants after each round. RESULTS: The majority of the 29 participating laboratories obtained satisfactory results, although low limits of quantification were required to quantify chromium concentrations in some of the ICI materials. The robust relative standard deviation of the participants' results (study RSDR) obtained from all ICI runs ranged from 6 to 16 % for U-Cr, 7-18 % for P-Cr and 4-47 % for WB-Cr. The application of both inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (EAAS) appeared appropriate for the determination of chromium in urine, plasma and whole blood with regard to occupational exposure levels. CONCLUSION: This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of chromium across Europe.
- MeSH
- biologický monitoring * MeSH
- chrom analýza MeSH
- lidé MeSH
- monitorování životního prostředí MeSH
- pracovní expozice * analýza MeSH
- spektrofotometrie atomová MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE OF THE STUDY Our study aimed to assess the mid-term outcomes and complications with the ICON hip resurfacing system and to carry out a detailed analysis of pitfalls and risks associated with pairing the bearing surfaces of metal-on-metal hip implants. MATERIAL AND METHODS A total of 52 hip joints were assessed in 43 patients who received the ICON hip resurfacing system at our department between 2009 and 2013. The cohort included 34 men and 9 women. Their age at the time of primary surgery ranged from 34 to 67 years, with the mean age of 51.8 years. The mean follow-up was 7.6 years. The evaluation focused on the position and osseointegration of both components, bone remodelling around the implant, and signs of potential aseptic loosening. The functional status of the hip was assessed by Harris Hip Score. RESULTS The primary stability of both components was always good, there were no femoral neck fractures reported in our cohort. All the acetabular components were stable, showing appropriate osseointegration, with no radiolucent zones or signs of osteolysis around them. There was not a single case of the femoral component stem being in a biomechanically disadvantageous varus position. In zone I and III according to Beaulé, cancellous bone osteolysis developed in two patients. The narrowing of the femoral neck below the end of the femoral component, compared to postoperative X-rays, achieved the mean value of 1.3% according to Grammatopolouse. The HHS increased from 64 to 95.5 points. An excellent outcome was observed in 48 joints, whereas the outcome of the remaining 4 joints was very good. The mean survival rate of the resurfacing hip implant calculated using the Kaplan-Meier analysis achieved 100%. The cobalt and chromium levels in the blood of patients did not exceed the reference physiological value. DISCUSSION The resurfacing system enables to preserve the bone tissue of the metaphysis and a part of the femoral head. The reduced mechanical endurance of the peripheral part of femoral components smaller in size caused by implant malposition resulted in fatal consequences in the ASR system. Greater range of motion conditioned by the design of the resurfacing system led to a mechanical wear, with a significant increase in the concentration of metal particles in the effective joint space. The elevated levels of cobalt and chromium ions in some patients induced delayed-type hypersensitivity with subsequent development of aseptic lymphocyte-dominated vasculitis associated lesions presented as peri-acetabular changes (pseudotumors to osteolysis) with subsequent failure of implant fixation. We have not observed this complication in the ICON system as yet. In patients suffering from hip pain after the resurfacing hip arthroplasty and simultaneous high chromium and cobalt blood levels, pelvic CT/MRI is indicated with reduction of artefacts around the metal material. Surgical treatment of soft tissue affections, bone defects and reimplantation using conventional or revisioncementless components is a possible treatment option. CONCLUSIONS The ideal patient indicated for hip resurfacing is a physically active man under 60 years of age (with a femoral head size of 54-60 mm), with primary or secondary osteoarthritis, no joint deformity, with a good quality bone tissue in the femoral neck and head region. As for the functional performance, the resurfacing system allows the patients a large range of motion with very good joint stability immediately after surgery. Despite that, the metal-on-metal tribological pairing must be approached with caution. The risk of developing lesions associated with ALVAL is unpredictable. In our cohort of patients with ICON hip resurfacing system, mostly excellent outcomes with minimum complications were reported provided the indication criteria and the correct surgical procedure had been complied with. Key words: hip resurfacing system, metal articulating surfaces, adverse reaction to metal particles, aseptic lymphocytedominated vasculitis associated lesions, pseudotumor.
- MeSH
- chrom MeSH
- dospělí MeSH
- kobalt MeSH
- kovy MeSH
- kyčelní kloub diagnostické zobrazování chirurgie MeSH
- kyčelní protézy * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada kyčelního kloubu * metody MeSH
- osteolýza * etiologie chirurgie MeSH
- protézy - design MeSH
- reoperace MeSH
- selhání protézy MeSH
- senioři MeSH
- vaskulitida * komplikace chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
The demand for biomaterials has been increasing along with the increase in the population of elderly people worldwide. The mechanical properties and high wear resistance of metallic biomaterials make them well-suited for use as substitutes or as support for damaged hard tissues. However, unless these biomaterials also have a low Young's modulus similar to that of human bones, bone atrophy inevitably occurs. Because a low Young's modulus is typically associated with poor wear resistance, it is difficult to realize a low Young's modulus and high wear resistance simultaneously. Also, the superelastic property of shape-memory alloys makes them suitable for biomedical applications, like vascular stents and guide wires. However, due to the low recoverable strain of conventional biocompatible shape-memory alloys, the demand for a new alloy system is high. The novel body-centered-cubic cobalt-chromium-based alloys in this work provide a solution to both of these problems. The Young's modulus of <001>-oriented single-crystal cobalt-chromium-based alloys is 10-30 GPa, which is similar to that of human bone, and they also demonstrate high wear and corrosion resistance. They also exhibit superelasticity with a huge recoverable strain up to 17.0%. For these reasons, the novel cobalt-chromium-based alloys can be promising candidates for biomedical applications.
Persistent use of pesticides and animal manure in agricultural soils inadvertently introduced heavy metals and antibiotic/antibiotic resistance genes (ARGs) into the soil with deleterious consequences. The microbiome and heavy metal and antibiotic resistome of a pesticide and animal manure inundated agricultural soil (SL6) obtained from a vegetable farm at Otte, Eiyenkorin, Kwara State, Nigeria, was deciphered via shotgun metagenomics and functional annotation of putative ORFs (open reading frames). Structural metagenomics of SL6 microbiome revealed 29 phyla, 49 classes, 94 orders, 183 families, 366 genera, 424 species, and 260 strains with the preponderance of the phyla Proteobacteria (40%) and Actinobacteria (36%), classes Actinobacteria (36%), Alphaproteobacteria (18%), and Gammaproteobacteria (17%), and genera Kocuria (16%), Sphingobacterium (11%), and Brevundimonas (10%), respectively. Heavy metal resistance genes annotation conducted using Biocide and Metal Resistance Gene Database (BacMet) revealed the detection of genes responsible for the uptake, transport, detoxification, efflux, and regulation of copper, cadmium, zinc, nickel, chromium, cobalt, selenium, tungsten, mercury, and several others. ARG annotation using the Antibiotic Resistance Gene-annotation (ARG-ANNOT) revealed ARGs for 11 antibiotic classes with the preponderance of β-lactamases, mobilized colistin resistance determinant (mcr-1), macrolide-lincosamide-streptogramin (MLS), glycopeptide, and aminoglycoside resistance genes, among others. The persistent use of pesticide and animal manure is strongly believed to play a major role in the proliferation of heavy metal and antibiotic resistance genes in the soil. This study revealed that agricultural soils inundated with pesticide and animal manure use are potential hotspots for ARG spread and may accentuate the spread of multidrug resistant clinical pathogens.
- MeSH
- aminoglykosidy MeSH
- antibakteriální látky farmakologie MeSH
- bakteriální geny MeSH
- beta-laktamasy genetika MeSH
- chrom MeSH
- dezinficiencia * MeSH
- glykopeptidy MeSH
- hnůj mikrobiologie MeSH
- kadmium MeSH
- kobalt MeSH
- kolistin MeSH
- linkosamidy MeSH
- makrolidy MeSH
- měď MeSH
- metagenomika MeSH
- mikrobiota * genetika MeSH
- nikl MeSH
- pesticidy * farmakologie MeSH
- půda chemie MeSH
- půdní mikrobiologie MeSH
- rtuť * MeSH
- selen * MeSH
- streptograminy MeSH
- wolfram MeSH
- zinek MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: Overweight and obesity are risk factors for many diseases, nutrition leading to these phenomena is not only a question of disbalance between energy intake and expenditure, but also the presence of micronutrients. In our study, we focused on measuring residues of chromium, zinc and iron in the hair of men with different BMI. METHODS: Hair samples and anthropometric questionnaires were collected from 45 males. Numbers of subjects and age structure were comparable between the three BMI groups. The determination of metal levels was performed by inductively coupled plasma mass spectrometry after mineralization of the hair. RESULTS: The hair of obese men contained significantly higher chromium (0.096 μg/g vs. 0.045 μg/g, p = 0.0039) and iron (9.42 μg/g vs. 5.84 μg/g, p = 0.0009) concentrations than that of overweight men, but no significant difference between the normal-weight group and the obese group were found. The concentration of zinc was lower in obese subjects compared to overweight subjects (183.5 μg/g vs. 206.2 μg/g, p = 0.038). Also, statistically significant correlations between chromium and iron concentrations in hair and BMI were found (r = 0.307, p = 0.040, r = 0.360, p = 0.015, respectively). According to our results, age did not significantly affect chromium, iron and zinc concentrations in hair. CONCLUSION: Consistent with some published studies, we have found that obese men have higher chromium and iron concentrations and lower zinc concentrations in hair.
- MeSH
- chrom MeSH
- lidé MeSH
- nadváha * MeSH
- obezita epidemiologie MeSH
- vlasy, chlupy * MeSH
- zinek MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH