A framework for alignment of on-board imagers of medical linear accelerators

M. Tulik, D. Kabat, RA. Kycia, Z. Tabor, A. Woszczyna, Z. Latała,

. 2018 ; 47 (-) : 80-85. [pub] 20180305

Language English Country Italy

Document type Journal Article

PURPOSE: To develop an assumption-free methodology for aligning the geometry of on-board imagers with the geometry of medical linear accelerators applied in image-guided radiotherapy (IGRT). MATERIAL: Alignment of the on-board imaging (OBI) system with respect to the accelerator system is achieved using a multi-modular phantom described elsewhere (Tabor et al., 2017), enabling the geometry of the linear accelerator to be specified without any pre-assumptions. METHODS: The placement of two isocentres (of the on-board imager and of the therapeutic system) and of three frames of reference (those of the on-board imager, of the therapeutic system, and of the treatment table) is formulated as an optimization problem. It is solved by analysing the images of fiducial points positioned in 3D space in phantom modules attached to the treatment table and to the collimator of the accelerator. Fiducials are projected onto an imaging plane of unknown characteristics from a virtual source of unknown coordinates. CONCLUSIONS: An analytical framework exploiting projection images of the proposed multi-modular phantom has been developed, enabling precise alignment of the reference frame related to the on-board imager with the reference frame related to the therapeutic system. Within the proposed framework, the necessary corrections of treatment table positioning prior to patient irradiation, are delivered in the treatment table coordinates.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18033198
003      
CZ-PrNML
005      
20181012102136.0
007      
ta
008      
181008s2018 it f 000 0|0eng||
009      
AR
024    7_
$a 10.1016/j.ejmp.2018.02.017 $2 doi
035    __
$a (PubMed)29609822
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a it
100    1_
$a Tulik, M $u Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology Cracow Branch, ul.Garncarska 11, 31-115 Kraków, Poland. Electronic address: mdtulik@gmail.com.
245    12
$a A framework for alignment of on-board imagers of medical linear accelerators / $c M. Tulik, D. Kabat, RA. Kycia, Z. Tabor, A. Woszczyna, Z. Latała,
520    9_
$a PURPOSE: To develop an assumption-free methodology for aligning the geometry of on-board imagers with the geometry of medical linear accelerators applied in image-guided radiotherapy (IGRT). MATERIAL: Alignment of the on-board imaging (OBI) system with respect to the accelerator system is achieved using a multi-modular phantom described elsewhere (Tabor et al., 2017), enabling the geometry of the linear accelerator to be specified without any pre-assumptions. METHODS: The placement of two isocentres (of the on-board imager and of the therapeutic system) and of three frames of reference (those of the on-board imager, of the therapeutic system, and of the treatment table) is formulated as an optimization problem. It is solved by analysing the images of fiducial points positioned in 3D space in phantom modules attached to the treatment table and to the collimator of the accelerator. Fiducials are projected onto an imaging plane of unknown characteristics from a virtual source of unknown coordinates. CONCLUSIONS: An analytical framework exploiting projection images of the proposed multi-modular phantom has been developed, enabling precise alignment of the reference frame related to the on-board imager with the reference frame related to the therapeutic system. Within the proposed framework, the necessary corrections of treatment table positioning prior to patient irradiation, are delivered in the treatment table coordinates.
650    _2
$a algoritmy $7 D000465
650    _2
$a kalibrace $7 D002138
650    _2
$a diagnostické zobrazování $x přístrojové vybavení $7 D003952
650    _2
$a počítačové zpracování obrazu $7 D007091
650    12
$a částice - urychlovače $7 D010315
650    _2
$a radioterapie s modulovanou intenzitou $7 D050397
655    _2
$a časopisecké články $7 D016428
700    1_
$a Kabat, D $u Maria Sklodowska-Curie Memorial Cancer Center and Institute of Oncology Cracow Branch, ul.Garncarska 11, 31-115 Kraków, Poland.
700    1_
$a Kycia, R A $u Cracow University of Technology, Faculty of Physics, Mathematics and Computer Science, ul. Warszawska 24, 31-155 Kraków, Poland; Department of Mathematics and Statistics, Masaryk University, Brno, Czech Republic.
700    1_
$a Tabor, Z $u Cracow University of Technology, Faculty of Physics, Mathematics and Computer Science, ul. Warszawska 24, 31-155 Kraków, Poland.
700    1_
$a Woszczyna, A $u Cracow University of Technology, Faculty of Physics, Mathematics and Computer Science, ul. Warszawska 24, 31-155 Kraków, Poland.
700    1_
$a Latała, Z $u Cracow University of Technology, Faculty of Mechanical Engineering, al. Jana Pawła II 37, 30-001 Kraków, Poland.
773    0_
$w MED00167391 $t Physica medica PM an international journal devoted to the applications of physics to medicine and biology official journal of the Italian Association of Biomedical Physics (AIFB) $x 1724-191X $g Roč. 47, č. - (2018), s. 80-85
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29609822 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20181012102628 $b ABA008
999    __
$a ok $b bmc $g 1340842 $s 1030192
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 47 $c - $d 80-85 $e 20180305 $i 1724-191X $m Physica medica $n Phys Med $x MED00167391
LZP    __
$a Pubmed-20181008

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...