Je něco špatně v tomto záznamu ?
Electrochemical quantum dots-based magneto-immunoassay for detection of HE4 protein on metal film-modified screen-printed carbon electrodes
M. Cadkova, A. Kovarova, V. Dvorakova, R. Metelka, Z. Bilkova, L. Korecka,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články
- MeSH
- biosenzitivní techniky * MeSH
- bismut chemie MeSH
- časná detekce nádoru MeSH
- elektrochemické techniky * MeSH
- elektrody MeSH
- exprese genu MeSH
- imunoanalýza * MeSH
- imunokonjugáty chemie metabolismus MeSH
- kvantové tečky chemie MeSH
- lidé MeSH
- nádorové biomarkery krev genetika MeSH
- nádory vaječníků krev diagnóza genetika patologie MeSH
- proteiny analýza genetika metabolismus MeSH
- protilátky chemie metabolismus MeSH
- rtuť chemie MeSH
- sloučeniny kadmia chemie MeSH
- sloučeniny selenu chemie MeSH
- sloučeniny zinku chemie MeSH
- uhlík chemie MeSH
- vazba proteinů MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
A novel enzyme-free electrochemical immunosensor was developed for highly sensitive detection and quantification of human epididymis protein 4 (HE4) in human serum. For the first time, core/shell CdSe/ZnS quantum dots were conjugated with anti-HE4 IgG antibodies for subsequent sandwich-type immunosensing with superparamagnetic microparticles functionalized with anti-HE4 IgG antibodies, which allow rapid and efficient HE4 capture from the sample. Electrochemical detection of anti-HE4 IgG - HE4 - anti-HE4 IgGCdSe/ZnS immunocomplex was performed by recording the current response of Cd(II) ions, released from dissolved quantum dots at screen-printed carbon electrode (SPCE), modified with mercury or bismuth film. The linear range of the detection was from 20 pM to 40 nM with limit of detection of 12 pM using three times the standard deviation of blank criterion at mercury-film SPCE and from 100 pM to 2 nM with limit of detection of 89 pM at bismuth-film SPCE. Proposed electrochemical immunosensor meets the requirements for fast and sensitive quantification of HE4 biomarker in early stage of ovarian cancer and due to the proper sensitivity and specificity presents a promising alternative to enzyme-based probes used routinely in clinical diagnostics.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18033271
- 003
- CZ-PrNML
- 005
- 20181008122218.0
- 007
- ta
- 008
- 181008s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2018.01.054 $2 doi
- 035 __
- $a (PubMed)29501129
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Cadkova, Michaela $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic.
- 245 10
- $a Electrochemical quantum dots-based magneto-immunoassay for detection of HE4 protein on metal film-modified screen-printed carbon electrodes / $c M. Cadkova, A. Kovarova, V. Dvorakova, R. Metelka, Z. Bilkova, L. Korecka,
- 520 9_
- $a A novel enzyme-free electrochemical immunosensor was developed for highly sensitive detection and quantification of human epididymis protein 4 (HE4) in human serum. For the first time, core/shell CdSe/ZnS quantum dots were conjugated with anti-HE4 IgG antibodies for subsequent sandwich-type immunosensing with superparamagnetic microparticles functionalized with anti-HE4 IgG antibodies, which allow rapid and efficient HE4 capture from the sample. Electrochemical detection of anti-HE4 IgG - HE4 - anti-HE4 IgGCdSe/ZnS immunocomplex was performed by recording the current response of Cd(II) ions, released from dissolved quantum dots at screen-printed carbon electrode (SPCE), modified with mercury or bismuth film. The linear range of the detection was from 20 pM to 40 nM with limit of detection of 12 pM using three times the standard deviation of blank criterion at mercury-film SPCE and from 100 pM to 2 nM with limit of detection of 89 pM at bismuth-film SPCE. Proposed electrochemical immunosensor meets the requirements for fast and sensitive quantification of HE4 biomarker in early stage of ovarian cancer and due to the proper sensitivity and specificity presents a promising alternative to enzyme-based probes used routinely in clinical diagnostics.
- 650 _2
- $a protilátky $x chemie $x metabolismus $7 D000906
- 650 _2
- $a nádorové biomarkery $x krev $x genetika $7 D014408
- 650 12
- $a biosenzitivní techniky $7 D015374
- 650 _2
- $a bismut $x chemie $7 D001729
- 650 _2
- $a sloučeniny kadmia $x chemie $7 D019187
- 650 _2
- $a uhlík $x chemie $7 D002244
- 650 _2
- $a časná detekce nádoru $7 D055088
- 650 12
- $a elektrochemické techniky $7 D055664
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a exprese genu $7 D015870
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a imunoanalýza $7 D007118
- 650 _2
- $a imunokonjugáty $x chemie $x metabolismus $7 D018796
- 650 _2
- $a rtuť $x chemie $7 D008628
- 650 _2
- $a nádory vaječníků $x krev $x diagnóza $x genetika $x patologie $7 D010051
- 650 _2
- $a vazba proteinů $7 D011485
- 650 _2
- $a proteiny $x analýza $x genetika $x metabolismus $7 D011506
- 650 _2
- $a kvantové tečky $x chemie $7 D045663
- 650 _2
- $a sloučeniny selenu $x chemie $7 D018036
- 650 _2
- $a sloučeniny zinku $x chemie $7 D017967
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kovarova, Aneta $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic.
- 700 1_
- $a Dvorakova, Veronika $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic.
- 700 1_
- $a Metelka, Radovan $u Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic.
- 700 1_
- $a Bilkova, Zuzana $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic.
- 700 1_
- $a Korecka, Lucie $u Department of Biological and Biochemical Sciences, Faculty of Chemical Technology, University of Pardubice, Studentska 573, 532 10 Pardubice, Czech Republic. Electronic address: lucie.korecka@upce.cz.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 182, č. - (2018), s. 111-115
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29501129 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20181008122705 $b ABA008
- 999 __
- $a ok $b bmc $g 1339410 $s 1030265
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 182 $c - $d 111-115 $e 20180131 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20181008