Detail
Article
Web resource
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Aspherical iols and their effect on visual acuity, depth of field, spherical aberration and contrast sensitivity

Vlasák O., Škorpíková J., Hlinomazová Z., Kalandrová V.

Language English Country Czech Republic

The work compares visual functions after cataract surgery and implantation of spherical (AAB00) and aspherical (ZCB00, MX60) intraocular lenses (IOL). The study was conducted in the years 2017-2018 at the European Eye Clinic Lexum Brno. The examined group contains 60 eyes. The study focused primarily on the comparison of distance corrected visual acuity (DCVA), the postoperative value of the total spherical aberration (SA), the depth of field (DoF) for the near and the contrast sensitivity. A single-factor ANOVA test was used for statistical analysis. Nearly all of the monitored values were statistically significantly better for the aspheric IOL group. It was DCVA (ZCB00: p = 0.048, MX60: p = 0.001), the total postoperative SA (ZCB00: p <0.000, MX60: p = 0.003) and contrast sensitivity in lower mesopic conditions (ZCB00: p=0,041; MX60: p = 0.012). Only DoF was statistically insignificant.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19000082
003      
CZ-PrNML
005      
20210623022746.0
007      
cr|cn|
008      
190104s2018 xr acd fs 000 0|eng||
009      
AR
024    0_
$a 10.31348/2018/1/1-3-2018 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Vlasák, Ondřej, $d 1984- $7 mub2017944325 $u Biophysical Institute, Faculty of Medicine, Masaryk University Brno; European Eye Clinic Lexum
245    10
$a Aspherical iols and their effect on visual acuity, depth of field, spherical aberration and contrast sensitivity / $c Vlasák O., Škorpíková J., Hlinomazová Z., Kalandrová V.
520    3_
$a The work compares visual functions after cataract surgery and implantation of spherical (AAB00) and aspherical (ZCB00, MX60) intraocular lenses (IOL). The study was conducted in the years 2017-2018 at the European Eye Clinic Lexum Brno. The examined group contains 60 eyes. The study focused primarily on the comparison of distance corrected visual acuity (DCVA), the postoperative value of the total spherical aberration (SA), the depth of field (DoF) for the near and the contrast sensitivity. A single-factor ANOVA test was used for statistical analysis. Nearly all of the monitored values were statistically significantly better for the aspheric IOL group. It was DCVA (ZCB00: p = 0.048, MX60: p = 0.001), the total postoperative SA (ZCB00: p <0.000, MX60: p = 0.003) and contrast sensitivity in lower mesopic conditions (ZCB00: p=0,041; MX60: p = 0.012). Only DoF was statistically insignificant.
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a extrakce katarakty $x metody $7 D002387
650    12
$a zraková ostrost $7 D014792
650    _2
$a citlivost na kontrast $7 D015350
650    _2
$a implantace nitrooční čočky $x metody $7 D019654
650    _2
$a refrakční chirurgické výkony $x metody $7 D054140
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a zrakové testy $7 D014787
650    12
$a nitrooční čočky $x klasifikace $x statistika a číselné údaje $7 D007910
650    _2
$a pooperační období $7 D011184
650    _2
$a statistika jako téma $7 D013223
650    _2
$a emetropie $7 D058453
653    _0
$a sférická aberace
653    00
$a korigovaná zraková ostrost do dálky
653    00
$a asférické nitrooční čočky
653    00
$a sférické nitrooční čočky
653    00
$a sférická aberace
700    1_
$a Škorpíková, Jiřina, $d 1945- $7 mzk2006368231 $u Biophysical Institute, Faculty of Medicine, Masaryk University Brno
700    1_
$a Hlinomazová, Zuzana, $u European Eye Clinic Lexum $d 1964- $7 nlk20010099055
700    1_
$a Kalandrová, Věra $u European Eye Clinic Lexum $7 xx0228671
773    0_
$t Czech and Slovak Ophthalmology $g Roč. 5, č. 3 (2018), s. 85-89 $w MED00194413
856    41
$u http://www.cs-ophthalmology.cz/en/journal/2018/3/1 $y plný text volně přístupný
910    __
$a ABA008 $b online $y p $z 0
990    __
$a 20190104132740 $b ABA008
991    __
$a 20210623022744 $b ABA008
999    __
$a ok $b bmc $g 1363075 $s 1038194
BAS    __
$a 3 $a 4
BMC    __
$a 2018 $b 5 $c 3 $d 85-89 $m Czech and Slovak Ophthalmology $x MED00194413
LZP    __
$c NLK189 $d 20210623 $a NLK 2019-01/pk

Find record

Citation metrics

Loading data ...