A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects

M. Bivolarova, J. Ondráček, A. Melikov, V. Ždímal,

. 2017 ; 27 (6) : 1201-1212. [pub] 20170504

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu srovnávací studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19001280

The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19001280
003      
CZ-PrNML
005      
20190121101958.0
007      
ta
008      
190107s2017 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1111/ina.12388 $2 doi
035    __
$a (PubMed)28378912
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Bivolarova, M $u Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark.
245    12
$a A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects / $c M. Bivolarova, J. Ondráček, A. Melikov, V. Ždímal,
520    9_
$a The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas.
650    _2
$a aerosoly $x analýza $7 D000336
650    _2
$a pohyb vzduchu $7 D000392
650    12
$a znečištění vzduchu ve vnitřním prostředí $7 D016902
650    _2
$a plyny $x analýza $7 D005740
650    _2
$a modely anatomické rozkládací $7 D008348
650    12
$a větrání $7 D014691
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ondráček, J $u Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic.
700    1_
$a Melikov, A $u Department of Civil Engineering, International Centre for Indoor Environment and Energy, Technical University of Denmark, Lyngby, Denmark.
700    1_
$a Ždímal, V $u Laboratory of Aerosol Chemistry and Physics, Institute of Chemical Process Fundamentals of the CAS, Prague, Czech Republic.
773    0_
$w MED00002225 $t Indoor air $x 1600-0668 $g Roč. 27, č. 6 (2017), s. 1201-1212
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28378912 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190107 $b ABA008
991    __
$a 20190121102216 $b ABA008
999    __
$a ok $b bmc $g 1365167 $s 1039403
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 27 $c 6 $d 1201-1212 $e 20170504 $i 1600-0668 $m Indoor air $n Indoor air $x MED00002225
LZP    __
$a Pubmed-20190107

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...