Zarděnkový screening testem radiální hemolýzy při aplikaci plné krve
[Rubella screening using a radial hemolysis test with whole blood]

J. Strauss, M. Mrázová, E. Svandová, O. Kokesová,

. 1989 ; 38 (6) : 348-354.

Jazyk čeština Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19003839
Odkazy

PubMed 2698765

The authors present the results of examination of 121 probands by the rubella test of radial haemolysis (RH), using capillary blood (direct test), as compared with the use of serum from venous blood in correlation with the rubella haemagglutination inhibition test. The diameter of the haemolytic zone, 7 mm, was as compared with the haemagglutination inhibition test in both modifications in 95% and the diameter 8 mm was seropositive in 100%. Haemolytic zones up to 6 mm must be considered seronegative even when some of the bloods or sera have bonder line haemagglutination inhibition titres. Seronegativity was expressed in the direct test of radial haemolysis by larger haemolytic zones. The specificity of the direct test of radial haemolysis, even when serum was used, was 87.5%, the sensitivity 88.2% and 88.4% resp. The reliability of positive diameters of haemolytic zones (7 mm+) is 99%, while that of negative ones (2-6 mm) only 35%. The less laborious direct test of RH proved equivalent to the radial haemolysis test using serum, as far as screening with the purpose of aimed immunization against rubella is concerned.

Rubella screening using a radial hemolysis test with whole blood

000      
00000naa a2200000 a 4500
001      
bmc19003839
003      
CZ-PrNML
005      
20190123100528.0
007      
ta
008      
190122s1989 xr f 000 0|cze||
009      
AR
035    __
$a (PubMed)2698765
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Strauss, J. $7 _AN053251
245    10
$a Zarděnkový screening testem radiální hemolýzy při aplikaci plné krve / $c J. Strauss, M. Mrázová, E. Svandová, O. Kokesová,
246    31
$a [Rubella screening using a radial hemolysis test with whole blood].
520    9_
$a The authors present the results of examination of 121 probands by the rubella test of radial haemolysis (RH), using capillary blood (direct test), as compared with the use of serum from venous blood in correlation with the rubella haemagglutination inhibition test. The diameter of the haemolytic zone, 7 mm, was as compared with the haemagglutination inhibition test in both modifications in 95% and the diameter 8 mm was seropositive in 100%. Haemolytic zones up to 6 mm must be considered seronegative even when some of the bloods or sera have bonder line haemagglutination inhibition titres. Seronegativity was expressed in the direct test of radial haemolysis by larger haemolytic zones. The specificity of the direct test of radial haemolysis, even when serum was used, was 87.5%, the sensitivity 88.2% and 88.4% resp. The reliability of positive diameters of haemolytic zones (7 mm+) is 99%, while that of negative ones (2-6 mm) only 35%. The less laborious direct test of RH proved equivalent to the radial haemolysis test using serum, as far as screening with the purpose of aimed immunization against rubella is concerned.
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a protilátky virové $x analýza $7 D000914
650    12
$a hemolytická plaková technika $7 D006462
650    _2
$a lidé $7 D006801
650    _2
$a zarděnky $x imunologie $7 D012409
650    _2
$a virus zarděnek $x imunologie $7 D012412
655    _2
$a časopisecké články $7 D016428
700    1_
$a Mrázová, Marie $7 xx0061412
700    1_
$a Švandová, Eva, $d 1938- $7 jn20020723045
700    1_
$a Kokesová, O
773    0_
$w MED00011163 $t Československá epidemiologie, mikrobiologie, imunologie $x 0009-0522 $g Roč. 38, č. 6 (1989), s. 348-354
856    41
$u https://pubmed.ncbi.nlm.nih.gov/2698765 $y Pubmed
910    __
$a ABA008 $b A 981 $c sign $y a $z 0
990    __
$a 20190122 $b ABA008
991    __
$a 20190123100748 $b ABA008
999    __
$a ok $b bmc $g 1370196 $s 1042016
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 1989 $b 38 $c 6 $d 348-354 $i 0009-0522 $m Československá epidemiologie, mikrobiologie, imunologie $n Českoslov. epidemiol. mikrobiol. imunol. $x MED00011163
LZP    __
$a Pubmed-20190122

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...