Effect of different resin luting cements on the marginal fit of lithium disilicate pressed crowns

R. Mounajjed, TJ. Salinas, T. Ingr, B. Azar,

. 2018 ; 119 (6) : 975-980. [pub] 20171115

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19013011

STATEMENT OF PROBLEM: The vertical marginal discrepancy of restorations can increase upon cementation, and poor marginal fit can lead to cement dissolution, marginal discoloration, microleakage, and secondary caries. The amount of increase is related to the type of luting cement used, but how lithium disilicate pressed crowns are affected by different resin cements is unclear. PURPOSE: The purpose of this in vitro study was to compare the effect of using different resin luting cements on the vertical marginal discrepancy of lithium disilicate pressed crowns. MATERIAL AND METHODS: A total of 18 intact extracted mandibular third molars were disinfected in a solution of 10% formalin for 7 days and were then prepared to receive a ceramic crown. Impressions were made with polyvinyl siloxane and lithium disilicate pressed crowns made and cemented with 1 of 3 resin luting cements. The marginal discrepancy was measured at 4 points on the finishing line of each tooth, with optical microscopy at ×200 magnification before and after cementation. Statistical analysis was done with the Kruskal-Wallis test to compare the median marginal increase among the 3 groups (a=.05). RESULTS: The least amount of marginal increase after cementation was with Harvard PremiumFlow cement, with an average marginal increase of 42 ±11 μm. RelyX Ultimate cement increased the margins by an average 45 ±29 μm. The highest marginal increase was found in the Enamel Plus HRi preheated composite resin group (116 ±47 μm). CONCLUSIONS: The marginal increase of pressed crowns cemented with preheated composite resin (Enamel Plus HRi) exceeded the clinically acceptable range of marginal discrepancy.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19013011
003      
CZ-PrNML
005      
20190416075903.0
007      
ta
008      
190405s2018 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.prosdent.2017.08.001 $2 doi
035    __
$a (PubMed)29150135
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Mounajjed, Radek $u Research Associate, Institute of Dentistry and Oral Sciences, Palacky University, Olomouc, Czech Republic.
245    10
$a Effect of different resin luting cements on the marginal fit of lithium disilicate pressed crowns / $c R. Mounajjed, TJ. Salinas, T. Ingr, B. Azar,
520    9_
$a STATEMENT OF PROBLEM: The vertical marginal discrepancy of restorations can increase upon cementation, and poor marginal fit can lead to cement dissolution, marginal discoloration, microleakage, and secondary caries. The amount of increase is related to the type of luting cement used, but how lithium disilicate pressed crowns are affected by different resin cements is unclear. PURPOSE: The purpose of this in vitro study was to compare the effect of using different resin luting cements on the vertical marginal discrepancy of lithium disilicate pressed crowns. MATERIAL AND METHODS: A total of 18 intact extracted mandibular third molars were disinfected in a solution of 10% formalin for 7 days and were then prepared to receive a ceramic crown. Impressions were made with polyvinyl siloxane and lithium disilicate pressed crowns made and cemented with 1 of 3 resin luting cements. The marginal discrepancy was measured at 4 points on the finishing line of each tooth, with optical microscopy at ×200 magnification before and after cementation. Statistical analysis was done with the Kruskal-Wallis test to compare the median marginal increase among the 3 groups (a=.05). RESULTS: The least amount of marginal increase after cementation was with Harvard PremiumFlow cement, with an average marginal increase of 42 ±11 μm. RelyX Ultimate cement increased the margins by an average 45 ±29 μm. The highest marginal increase was found in the Enamel Plus HRi preheated composite resin group (116 ±47 μm). CONCLUSIONS: The marginal increase of pressed crowns cemented with preheated composite resin (Enamel Plus HRi) exceeded the clinically acceptable range of marginal discrepancy.
650    12
$a zubní korunky $7 D003442
650    12
$a zubní cementy $7 D003738
650    12
$a zubní porcelán $7 D003776
650    _2
$a lidé $7 D006801
650    _2
$a techniky in vitro $7 D066298
650    _2
$a moláry $7 D008963
650    12
$a pryskyřičné cementy $7 D019279
655    _2
$a časopisecké články $7 D016428
700    1_
$a Salinas, Thomas J $u Professor, Dentistry, Mayo Clinic, Rochester, Minn.
700    1_
$a Ingr, Tomas $u Doctoral student, Department of Experimental Physics, Palacky University, Olomouc, Czech Republic.
700    1_
$a Azar, Basel $u Research Associate, Institute of Dentistry and Oral Sciences, Palacky University, Olomouc, Czech Republic. Electronic address: baselazar1@hotmail.com.
773    0_
$w MED00002910 $t The Journal of prosthetic dentistry $x 1097-6841 $g Roč. 119, č. 6 (2018), s. 975-980
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29150135 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190405 $b ABA008
991    __
$a 20190416075929 $b ABA008
999    __
$a ok $b bmc $g 1392321 $s 1051316
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 119 $c 6 $d 975-980 $e 20171115 $i 1097-6841 $m The Journal of prosthetic dentistry $n J Prosthet Dent $x MED00002910
LZP    __
$a Pubmed-20190405

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...