• Je něco špatně v tomto záznamu ?

Development of an autonomous station for measurements of artificial gamma activity in surface water bodies

M. Fejgl, M. Hýža,

. 2019 ; 204 (-) : 42-48. [pub] 20190406

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19027667

This paper reports on the structure of the autonomous station for monitoring artificial gamma activity in surface water bodies for the purposes of emergency preparedness of the Czech Republic. A simple design based on the NaI(Tl) submersible detector powered by a combined solar and wind source has been employed. Data transfer is provided by a satellite connection. The detection capabilities of the device have been tested for various unfavourable conditions, and the detection limits have been lowered by using the noise adjustment singular value decomposition (NASVD) method. The detection capabilities of the device fulfil the legal requirements for emergency monitoring, and are almost equal to the detection capabilities of other available devices with a more complicated and less versatile structure.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19027667
003      
CZ-PrNML
005      
20190823121922.0
007      
ta
008      
190813s2019 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jenvrad.2019.04.001 $2 doi
035    __
$a (PubMed)30965215
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Fejgl, Michal $u National Radiation Protection Institute, Bartoškova 28, Prague 4, 140 00, Czech Republic. Electronic address: michal.fejgl@suro.cz.
245    10
$a Development of an autonomous station for measurements of artificial gamma activity in surface water bodies / $c M. Fejgl, M. Hýža,
520    9_
$a This paper reports on the structure of the autonomous station for monitoring artificial gamma activity in surface water bodies for the purposes of emergency preparedness of the Czech Republic. A simple design based on the NaI(Tl) submersible detector powered by a combined solar and wind source has been employed. Data transfer is provided by a satellite connection. The detection capabilities of the device have been tested for various unfavourable conditions, and the detection limits have been lowered by using the noise adjustment singular value decomposition (NASVD) method. The detection capabilities of the device fulfil the legal requirements for emergency monitoring, and are almost equal to the detection capabilities of other available devices with a more complicated and less versatile structure.
650    _2
$a radioizotopy cesia $x analýza $7 D002588
650    _2
$a záření gama $7 D005720
650    _2
$a radioizotopy jodu $x analýza $7 D007457
650    _2
$a monitorování radiace $x přístrojové vybavení $7 D011834
650    _2
$a spektrometrie gama $x přístrojové vybavení $7 D013051
650    _2
$a radioaktivní látky znečišťující vodu $x analýza $7 D014875
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
700    1_
$a Hýža, Miroslav $u National Radiation Protection Institute, Bartoškova 28, Prague 4, 140 00, Czech Republic. Electronic address: miroslav.hyza@suro.cz.
773    0_
$w MED00002660 $t Journal of environmental radioactivity $x 1879-1700 $g Roč. 204, č. - (2019), s. 42-48
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30965215 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190823122137 $b ABA008
999    __
$a ok $b bmc $g 1432816 $s 1066127
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 204 $c - $d 42-48 $e 20190406 $i 1879-1700 $m Journal of environmental radioactivity $n J Environ Radioact $x MED00002660
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...