• Je něco špatně v tomto záznamu ?

Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation

O. Belohlavek, M. Jaruskova, M. Skopalova, G. Szarazova, K. Simonova,

. 2019 ; 46 (2) : 297-303. [pub] 20180829

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028246

PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 patients with mild cognitive impairment. Five nuclear medicine physicians blindly and independently evaluated all late-phase scans, initially employing the STD method and later the GM-EDGE method. A five-point scale was used to express the degree of amyloid positivity, and a binary classification (positive/negative) was used in combination with subjective confidence (five-point scale). Multirater Fleiss' kappa, intraclass correlation coefficient (ICC) and inter-rater reliability (Cohen's kappa) were determined for the STD and GM-EDGE methods. RESULTS: The weighted Cohen's kappa values for the five-point measure of amyloid positivity ranged from 0.63 to 0.73 (median 0.70) for the STD method and from 0.76 to 0.89 (median 0.80) for the GM-EDGE method (ICC 0.84, 95% CI 0.79-0.88, for the STD method; 0.91, 95% CI 0.89-0.94, for the GM-EDGE method). The nonweighted Cohen's kappa value for the binary classification ranged from 0.73 to 0.93 (median 0.82) for the STD method and 0.90 to 0.97 (median 0.93) for the GM-EDGE method (Fleiss' kappa 0.82, 95% CI 0.77-0.88, for the STD method; 0.93, 95% CI 0.87-0.99, for the GM-EDGE method). The GM-EDGE method resulted in significantly greater subjective confidence in the readings of four physicians (p < 0.010). The binary classification was concordant among all five physicians in 80.8% of the scans using the STD method and in 91.6% of the scans using the GM-EDGE method (p = 0.016). CONCLUSION: The newly introduced GM-EDGE method was associated with significantly higher inter-rater agreement among physicians and higher subjective confidence in the reading. The method is easy to implement in clinical practice, especially when the perfusion phase is utilized clinically.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028246
003      
CZ-PrNML
005      
20190823120942.0
007      
ta
008      
190813s2019 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00259-018-4140-y $2 doi
035    __
$a (PubMed)30159586
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Belohlavek, Otakar $u Department of Nuclear Medicine - PET Centre, Na Homolce Hospital, Roentgenova 37/2, 150 30, Prague 5, Czech Republic. otakar.belohlavek@homolka.cz.
245    10
$a Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation / $c O. Belohlavek, M. Jaruskova, M. Skopalova, G. Szarazova, K. Simonova,
520    9_
$a PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 patients with mild cognitive impairment. Five nuclear medicine physicians blindly and independently evaluated all late-phase scans, initially employing the STD method and later the GM-EDGE method. A five-point scale was used to express the degree of amyloid positivity, and a binary classification (positive/negative) was used in combination with subjective confidence (five-point scale). Multirater Fleiss' kappa, intraclass correlation coefficient (ICC) and inter-rater reliability (Cohen's kappa) were determined for the STD and GM-EDGE methods. RESULTS: The weighted Cohen's kappa values for the five-point measure of amyloid positivity ranged from 0.63 to 0.73 (median 0.70) for the STD method and from 0.76 to 0.89 (median 0.80) for the GM-EDGE method (ICC 0.84, 95% CI 0.79-0.88, for the STD method; 0.91, 95% CI 0.89-0.94, for the GM-EDGE method). The nonweighted Cohen's kappa value for the binary classification ranged from 0.73 to 0.93 (median 0.82) for the STD method and 0.90 to 0.97 (median 0.93) for the GM-EDGE method (Fleiss' kappa 0.82, 95% CI 0.77-0.88, for the STD method; 0.93, 95% CI 0.87-0.99, for the GM-EDGE method). The GM-EDGE method resulted in significantly greater subjective confidence in the readings of four physicians (p < 0.010). The binary classification was concordant among all five physicians in 80.8% of the scans using the STD method and in 91.6% of the scans using the GM-EDGE method (p = 0.016). CONCLUSION: The newly introduced GM-EDGE method was associated with significantly higher inter-rater agreement among physicians and higher subjective confidence in the reading. The method is easy to implement in clinical practice, especially when the perfusion phase is utilized clinically.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a amyloidní beta-protein $x metabolismus $7 D016229
650    _2
$a kognitivní dysfunkce $x diagnostické zobrazování $x metabolismus $7 D060825
650    _2
$a šedá hmota $x diagnostické zobrazování $x metabolismus $7 D066128
650    _2
$a lidé $7 D006801
650    12
$a počítačové zpracování obrazu $7 D007091
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    12
$a PET/CT $7 D000072078
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jaruskova, Monika $u Department of Nuclear Medicine - PET Centre, Na Homolce Hospital, Roentgenova 37/2, 150 30, Prague 5, Czech Republic.
700    1_
$a Skopalova, Magdalena $u Department of Nuclear Medicine - PET Centre, Na Homolce Hospital, Roentgenova 37/2, 150 30, Prague 5, Czech Republic.
700    1_
$a Szarazova, Gabriela $u Department of Nuclear Medicine - PET Centre, Na Homolce Hospital, Roentgenova 37/2, 150 30, Prague 5, Czech Republic.
700    1_
$a Simonova, Katerina $u Department of Nuclear Medicine - PET Centre, Na Homolce Hospital, Roentgenova 37/2, 150 30, Prague 5, Czech Republic.
773    0_
$w MED00007222 $t European journal of nuclear medicine and molecular imaging $x 1619-7089 $g Roč. 46, č. 2 (2019), s. 297-303
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30159586 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190823121156 $b ABA008
999    __
$a ok $b bmc $g 1433395 $s 1066706
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 46 $c 2 $d 297-303 $e 20180829 $i 1619-7089 $m European journal of nuclear medicine and molecular imaging $n Eur J Nucl Med Mol Imaging $x MED00007222
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...