Dosimetry as a Catch in Radiobiology Experiments

M. Šefl, K. Pachnerová Brabcová, V. Štěpán,

. 2018 ; 190 (4) : 404-411. [pub] 20180717

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028319

Experimental radiobiological studies in which the effects of ionizing radiation on a biological model are examined often highlight the biological aspects while missing detailed descriptions of the geometry, sample and dosimetric methods used. Such omissions can hinder the reproducibility and comparability of the experimental data. An application based on the Geant4 simulation toolkit was developed to design experiments using a biological solution placed in a microtube. The application was used to demonstrate the influence of the type of microtube, sample volume and energy of a proton source on the dose distribution across the sample, and on the mean dose in the whole sample. The results shown here are for samples represented by liquid water in the 0.4-, 1.5- and 2.0-ml microtubes irradiated with 20, 30 and 100 MeV proton beams. The results of this work demonstrate that the mean dose and homogeneity of the dose distribution within the sample strongly depend on all three parameters. Furthermore, this work shows how the dose uncertainty propagates into the scored primary DNA damages in plasmid DNA studies using agarose gel electrophoresis. This application is provided freely to assist users in verifying their experimental setup prior to the experiment.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028319
003      
CZ-PrNML
005      
20190822100424.0
007      
ta
008      
190813s2018 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1667/RR15020.1 $2 doi
035    __
$a (PubMed)30016217
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Šefl, Martin $u a   Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic. b   Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
245    10
$a Dosimetry as a Catch in Radiobiology Experiments / $c M. Šefl, K. Pachnerová Brabcová, V. Štěpán,
520    9_
$a Experimental radiobiological studies in which the effects of ionizing radiation on a biological model are examined often highlight the biological aspects while missing detailed descriptions of the geometry, sample and dosimetric methods used. Such omissions can hinder the reproducibility and comparability of the experimental data. An application based on the Geant4 simulation toolkit was developed to design experiments using a biological solution placed in a microtube. The application was used to demonstrate the influence of the type of microtube, sample volume and energy of a proton source on the dose distribution across the sample, and on the mean dose in the whole sample. The results shown here are for samples represented by liquid water in the 0.4-, 1.5- and 2.0-ml microtubes irradiated with 20, 30 and 100 MeV proton beams. The results of this work demonstrate that the mean dose and homogeneity of the dose distribution within the sample strongly depend on all three parameters. Furthermore, this work shows how the dose uncertainty propagates into the scored primary DNA damages in plasmid DNA studies using agarose gel electrophoresis. This application is provided freely to assist users in verifying their experimental setup prior to the experiment.
650    _2
$a poškození DNA $7 D004249
650    _2
$a elektroforéza v agarovém gelu $7 D004587
650    _2
$a biologické modely $7 D008954
650    _2
$a plazmidy $7 D010957
650    _2
$a protony $7 D011522
650    12
$a dávka záření $7 D011829
650    _2
$a ionizující záření $7 D011839
650    _2
$a radiometrie $x metody $7 D011874
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a nejistota $7 D035501
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Pachnerová Brabcová, Kateřina $u a   Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic.
700    1_
$a Štěpán, Václav $u a   Nuclear Physics Institute of the Czech Academy of Sciences, Prague, Czech Republic.
773    0_
$w MED00010511 $t Radiation research $x 1938-5404 $g Roč. 190, č. 4 (2018), s. 404-411
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30016217 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190822100703 $b ABA008
999    __
$a ok $b bmc $g 1433468 $s 1066779
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 190 $c 4 $d 404-411 $e 20180717 $i 1938-5404 $m Radiation research $n Radiat Res $x MED00010511
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...