Activation of QA devices and phantom materials under clinical scanning proton beams-a gamma spectrometry study

T. Hanušová, K. Johnová, M. Navrátil, J. Valenta, L. Müller,

. 2018 ; 63 (11) : 115014. [pub] 20180607

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028445

Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028445
003      
CZ-PrNML
005      
20190822091851.0
007      
ta
008      
190813s2018 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1088/1361-6560/aac27f $2 doi
035    __
$a (PubMed)29726411
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Hanušová, Tereza $u Faculty of Nuclear Sciences and Physical Engineering, Department of Dosimetry and Application of Ionizing Radiation, Czech Technical University in Prague, Břehová 7, 115 19 Praha 1, Czechia.
245    10
$a Activation of QA devices and phantom materials under clinical scanning proton beams-a gamma spectrometry study / $c T. Hanušová, K. Johnová, M. Navrátil, J. Valenta, L. Müller,
520    9_
$a Activation of detectors and phantoms used for commissioning and quality assurance of clinical proton beams may lead to radiation protection issues. Good understanding of the activation nuclide vectors involved is necessary to assess radiation risk for the personnel working with these devices on a daily basis or to fulfill legal requirements regarding transport of radioactive material and its release to the public. 11 devices and material samples were irradiated with a 220 MeV proton pencil beam (PBS, Proton Therapy Center, Prague). This study focuses on devices manufactured by IBA Dosimetry GmbH: MatriXX PT, PPC05, Stingray, Zebra, Lynx, a Blue Phantom rail and samples of RW3, PMMA, titanium, copper and carbon fibre plastic. Monitor units (MU) were monitored during delivery. Gamma spectrometry was then performed for each item using a HPGe detector, with a focus on longer lived gamma emitting radionuclides. Activities were quantified for all found isotopes and compared to relevant legal limits for exemption and clearance of radioactive objects. Activation was found to be significant after long irradiation sessions, as done during commissioning of a proton therapy room. Some of the investigated devices may also cumulate activity in time, depending on the scenario of periodic irradiation in routine clinical practice. However, the levels of activity and resulting beta/gamma doses are more comparable to internationally recommended concentration limits for exemption than to dose limits for radiation workers. Results of this study will help to determine nuclide inventories required by some legal authorities for radiation protection purposes.
650    _2
$a lidé $7 D006801
650    _2
$a fantomy radiodiagnostické $7 D019047
650    _2
$a protonová terapie $x přístrojové vybavení $x metody $7 D061766
650    12
$a protony $7 D011522
650    _2
$a radiometrie $x přístrojové vybavení $7 D011874
650    _2
$a spektrometrie gama $x přístrojové vybavení $x metody $7 D013051
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Johnová, Kamila
700    1_
$a Navrátil, Matěj
700    1_
$a Valenta, Jiří
700    1_
$a Müller, Lutz
773    0_
$w MED00003821 $t Physics in medicine and biology $x 1361-6560 $g Roč. 63, č. 11 (2018), s. 115014
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29726411 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190822092129 $b ABA008
999    __
$a ok $b bmc $g 1433594 $s 1066905
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 63 $c 11 $d 115014 $e 20180607 $i 1361-6560 $m Physics in medicine and biology $n Phys Med Biol $x MED00003821
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...