Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech

JG. Švec, S. Granqvist,

. 2018 ; 61 (3) : 441-461. [pub] 20180315

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028572

Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Method: Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Results: Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. Conclusions: SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028572
003      
CZ-PrNML
005      
20190830115042.0
007      
ta
008      
190813s2018 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1044/2017_JSLHR-S-17-0095 $2 doi
035    __
$a (PubMed)29450495
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Švec, Jan G $u Department of Biophysics, Faculty of Science, Palacký University, Olomouc, Czech Republic.
245    10
$a Tutorial and Guidelines on Measurement of Sound Pressure Level in Voice and Speech / $c JG. Švec, S. Granqvist,
520    9_
$a Purpose: Sound pressure level (SPL) measurement of voice and speech is often considered a trivial matter, but the measured levels are often reported incorrectly or incompletely, making them difficult to compare among various studies. This article aims at explaining the fundamental principles behind these measurements and providing guidelines to improve their accuracy and reproducibility. Method: Basic information is put together from standards, technical, voice and speech literature, and practical experience of the authors and is explained for nontechnical readers. Results: Variation of SPL with distance, sound level meters and their accuracy, frequency and time weightings, and background noise topics are reviewed. Several calibration procedures for SPL measurements are described for stand-mounted and head-mounted microphones. Conclusions: SPL of voice and speech should be reported together with the mouth-to-microphone distance so that the levels can be related to vocal power. Sound level measurement settings (i.e., frequency weighting and time weighting/averaging) should always be specified. Classified sound level meters should be used to assure measurement accuracy. Head-mounted microphones placed at the proximity of the mouth improve signal-to-noise ratio and can be taken advantage of for voice SPL measurements when calibrated. Background noise levels should be reported besides the sound levels of voice and speech.
650    _2
$a elektrické vybavení a zdroje $7 D055615
650    _2
$a směrnice pro lékařskou praxi jako téma $7 D017410
650    _2
$a tlak $7 D011312
650    12
$a řeč $7 D013060
650    _2
$a měření tvorby řeči $x přístrojové vybavení $x metody $7 D013068
650    12
$a hlas $7 D014831
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a přehledy $7 D016454
700    1_
$a Granqvist, Svante $u Department of Basic Science and Biomedicine, School of Technology and Health, Royal Institute of Technology, Stockholm, Sweden. Division of Speech and Language Pathology, Department of Clinical Science, Intervention and Technology, Karolinska Institutet, Stockholm, Sweden.
773    0_
$w MED00005429 $t Journal of speech, language, and hearing research : JSLHR $x 1558-9102 $g Roč. 61, č. 3 (2018), s. 441-461
856    41
$u https://pubmed.ncbi.nlm.nih.gov/29450495 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190830115406 $b ABA008
999    __
$a ok $b bmc $g 1433721 $s 1067032
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2018 $b 61 $c 3 $d 441-461 $e 20180315 $i 1558-9102 $m Journal of speech, language, and hearing research $n J Speech Lang Hear Res $x MED00005429
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...