Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation

S. Key, G. Scott, JG. Stammers, MAR. Freeman, V. Pinskerova, RE. Field, J. Skinner, SA. Banks,

. 2019 ; 8 (5) : 207-215. [pub] 20190605

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19028864

Objectives: The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods: Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results: Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion: No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities.Cite this article: S. Key, G. Scott, J.G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207-215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19028864
003      
CZ-PrNML
005      
20190822085055.0
007      
ta
008      
190813s2019 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1302/2046-3758.85.BJR-2018-0237.R1 $2 doi
035    __
$a (PubMed)31214333
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Key, S $u Royal London Hospital, London, UK.
245    10
$a Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation / $c S. Key, G. Scott, JG. Stammers, MAR. Freeman, V. Pinskerova, RE. Field, J. Skinner, SA. Banks,
520    9_
$a Objectives: The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods: Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results: Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion: No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities.Cite this article: S. Key, G. Scott, J.G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207-215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Scott, G $u Royal London Hospital, London, UK.
700    1_
$a Stammers, J G $u Royal London Hospital, London, UK.
700    1_
$a Freeman, M A R $u †M.A.R Freeman has deceased since the submission of this manuscript.
700    1_
$a Pinskerova, V $u First Orthopaedic Clinic, Faculty of Medicine, Charles University, Prague, Czech Republic.
700    1_
$a Field, R E $u St George's, University of London, London, UK; Director of Research, South West London Elective Orthopaedic Centre, Epsom, UK.
700    1_
$a Skinner, J $u Royal National Orthopaedic Hospital, Stanmore, UK.
700    1_
$a Banks, S A $u University of Florida, Gainesville, Florida, USA.
773    0_
$w MED00188738 $t Bone & joint research $x 2046-3758 $g Roč. 8, č. 5 (2019), s. 207-215
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31214333 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20190813 $b ABA008
991    __
$a 20190822085333 $b ABA008
999    __
$a ind $b bmc $g 1434013 $s 1067324
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 8 $c 5 $d 207-215 $e 20190605 $i 2046-3758 $m Bone & joint research $n Bone Joint Res $x MED00188738
LZP    __
$a Pubmed-20190813

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...