Je něco špatně v tomto záznamu ?
Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation
S. Key, G. Scott, JG. Stammers, MAR. Freeman, V. Pinskerova, RE. Field, J. Skinner, SA. Banks,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2012
Free Medical Journals
od 2012
Freely Accessible Science Journals
od 2012
PubMed Central
od 2012
Europe PubMed Central
od 2012
Open Access Digital Library
od 2012-01-01
Open Access Digital Library
od 2012-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2012
- Publikační typ
- časopisecké články MeSH
Objectives: The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods: Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results: Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion: No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities.Cite this article: S. Key, G. Scott, J.G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207-215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1.
†M A R Freeman has deceased since the submission of this manuscript
1st Orthopaedic Clinic Faculty of Medicine Charles University Prague Czech Republic
Director of Research South West London Elective Orthopaedic Centre Epsom UK
Royal London Hospital London UK
Royal National Orthopaedic Hospital Stanmore UK
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19028864
- 003
- CZ-PrNML
- 005
- 20190822085055.0
- 007
- ta
- 008
- 190813s2019 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1302/2046-3758.85.BJR-2018-0237.R1 $2 doi
- 035 __
- $a (PubMed)31214333
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Key, S $u Royal London Hospital, London, UK.
- 245 10
- $a Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation / $c S. Key, G. Scott, JG. Stammers, MAR. Freeman, V. Pinskerova, RE. Field, J. Skinner, SA. Banks,
- 520 9_
- $a Objectives: The medially spherical GMK Sphere (Medacta International AG, Castel San Pietro, Switzerland) total knee arthroplasty (TKA) was previously shown to accommodate lateral rollback while pivoting around a stable medial compartment, aiming to replicate native knee kinematics in which some coronal laxity, especially laterally, is also present. We assess coronal plane kinematics of the GMK Sphere and explore the occurrence and pattern of articular separation during static and dynamic activities. Methods: Using pulsed fluoroscopy and image matching, the coronal kinematics and articular surface separation of 16 well-functioning TKAs were studied during weight-bearing and non-weight-bearing, static, and dynamic activities. The closest distances between the modelled articular surfaces were examined with respect to knee position, and proportions of joint poses exhibiting separation were computed. Results: Overall, 1717 joint poses were analyzed. At a 1.0 mm detection threshold, 37 instances of surface separation were observed in the lateral compartment and four medially (p < 0.001). Separation was activity-dependent, both laterally and medially (p < 0.001), occurring more commonly during static deep flexion in the lateral compartment, and during static rotation in the medial compartment. Lateral separation occurred more frequently than medial during kneeling (7/14 lateral vs 1/14 medial; p = 0.031) and stepping (20/1022 lateral vs 0/1022 medial; p < 0.001). Separation varied significantly between individuals during dynamic activities. Conclusion: No consistent association between closest distances of the articular surfaces and knee position was found during any activity. Lift-off was infrequent and depended on the activity performed and the individual knee. Lateral separation was consistent with the design rationale. Medial lift-off was rare and mostly in non-weight-bearing activities.Cite this article: S. Key, G. Scott, J.G. Stammers, M. A. R. Freeman†, V. Pinskerova, R. E. Field, J. Skinner, S. A. Banks. Does lateral lift-off occur in static and dynamic activity in a medially spherical total knee arthroplasty? A pulsed-fluoroscopic investigation. Bone Joint Res 2019;8:207-215. DOI: 10.1302/2046-3758.85.BJR-2018-0237.R1.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Scott, G $u Royal London Hospital, London, UK.
- 700 1_
- $a Stammers, J G $u Royal London Hospital, London, UK.
- 700 1_
- $a Freeman, M A R $u †M.A.R Freeman has deceased since the submission of this manuscript.
- 700 1_
- $a Pinskerova, V $u First Orthopaedic Clinic, Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Field, R E $u St George's, University of London, London, UK; Director of Research, South West London Elective Orthopaedic Centre, Epsom, UK.
- 700 1_
- $a Skinner, J $u Royal National Orthopaedic Hospital, Stanmore, UK.
- 700 1_
- $a Banks, S A $u University of Florida, Gainesville, Florida, USA.
- 773 0_
- $w MED00188738 $t Bone & joint research $x 2046-3758 $g Roč. 8, č. 5 (2019), s. 207-215
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31214333 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190822085333 $b ABA008
- 999 __
- $a ind $b bmc $g 1434013 $s 1067324
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 8 $c 5 $d 207-215 $e 20190605 $i 2046-3758 $m Bone & joint research $n Bone Joint Res $x MED00188738
- LZP __
- $a Pubmed-20190813