• Je něco špatně v tomto záznamu ?

Ztráta korekce zlomeniny patní kosti dle typů osteosyntézy [Correction loss of calcaneal fractures by different type of osteosynthesis]

K. Gajdošíková, R. Veselý, R. Suchomel, M. Budoš

. 2019 ; 86 (2) : 124-130.

Jazyk čeština Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19030801

Digitální knihovna NLK
Zdroj

E-zdroje Online

NLK Free Medical Journals od 2006

Odkazy

PubMed 31070571

PURPOSE OF THE STUDY The calcaneal bone is affected in 2% of body fractures. Because of its major influence to walking stability with its permanent consequences affecting both daily living and work activities, huge effort is expended on suitable treatment of these fractures. Many studies have focused on surgical treatment of calcaneal fractures or on comparing operative and non-operative treatment. The aim of this retrospective study is to investigate stability of different type of osteosynthesis. MATERIAL AND METHODS This study involves 119 men and 24 women aged 20 to 84 years who were in the period from 2011 to 2015 surgically treated for broken calcaneus in the Trauma Hospital in Brno - this study covers 152 calcaneal fractures in 143 patients. The calcaneal fractures were classified into Sanders I-IV subgroups based on the CT scans and divided by the applied type of osteosynthesis. The Böhler and Gissane angle as well as height, width and length of calcaneal bone at the time after reposition and stabilization and at 3 and 12 months after the trauma were compared. Also tracked was the relationship between the imaging scans and the clinical assessment based on the AOFAS Ankle-Hindfoot Scale (A-H score). RESULTS Decrease of the Bohler angle (increment of the Gissane angle) of more than 5 degrees and reduction of height and extension of length or width of the calcaneal bone of more than 2 mm were defined as a criterion of osteosynthesis failure. These conditions were met in 53 surgically treated calcaneal fractures (35% of the total). In 17 cases the angular stable plate failed (it is 36% of the used plates), in 21 cases it was the C-nails (42%) and in 11 cases the screws (24%) that failed. In this group, 20 patients (38%) were satisfied with 100 points in the A-H score, 16 patients (30%) felt good, 11 patients (21%) quite good and 5 patients (9%) felt bad. DISCUSSION It is difficult to compare the stability of different types of osteosynthesis in a retrospective study because of the compliance impossibility, differences in the follow-up time and distortion of X-rays. The results are distorted in uncooperative patients, smokers, alcohol abusers and in elderly patients. CONCLUSIONS The stability of different types of osteosynthesis is almost equal - the most stable is the screw synthesis (24% probability of failure), the plates show 36% odds of failure, and the most unstable seem to be the C-nails with 42% probability of failure. However, these results do not correlate with the clinical conditions according to the A-H score. Key words: calcaneal fracture, locking plate, intramedullary nail.

Correction loss of calcaneal fractures by different type of osteosynthesis

000      
00000naa a2200000 a 4500
001      
bmc19030801
003      
CZ-PrNML
005      
20240905083432.0
007      
ta
008      
190902s2019 xr f 000 0|cze||
009      
AR
024    7_
$2 doi $a 10.55095/achot2019/017
035    __
$a (PubMed)31070571
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a cze
044    __
$a xr
100    1_
$a Gajdošíková, Kateřina. $7 xx0240933 $u Klinika traumatologie Lékařské fakulty Masarykovy univerzity, Úrazová nemocnice v Brně
245    10
$a Ztráta korekce zlomeniny patní kosti dle typů osteosyntézy / $c K. Gajdošíková, R. Veselý, R. Suchomel, M. Budoš
246    31
$a Correction loss of calcaneal fractures by different type of osteosynthesis
520    9_
$a PURPOSE OF THE STUDY The calcaneal bone is affected in 2% of body fractures. Because of its major influence to walking stability with its permanent consequences affecting both daily living and work activities, huge effort is expended on suitable treatment of these fractures. Many studies have focused on surgical treatment of calcaneal fractures or on comparing operative and non-operative treatment. The aim of this retrospective study is to investigate stability of different type of osteosynthesis. MATERIAL AND METHODS This study involves 119 men and 24 women aged 20 to 84 years who were in the period from 2011 to 2015 surgically treated for broken calcaneus in the Trauma Hospital in Brno - this study covers 152 calcaneal fractures in 143 patients. The calcaneal fractures were classified into Sanders I-IV subgroups based on the CT scans and divided by the applied type of osteosynthesis. The Böhler and Gissane angle as well as height, width and length of calcaneal bone at the time after reposition and stabilization and at 3 and 12 months after the trauma were compared. Also tracked was the relationship between the imaging scans and the clinical assessment based on the AOFAS Ankle-Hindfoot Scale (A-H score). RESULTS Decrease of the Bohler angle (increment of the Gissane angle) of more than 5 degrees and reduction of height and extension of length or width of the calcaneal bone of more than 2 mm were defined as a criterion of osteosynthesis failure. These conditions were met in 53 surgically treated calcaneal fractures (35% of the total). In 17 cases the angular stable plate failed (it is 36% of the used plates), in 21 cases it was the C-nails (42%) and in 11 cases the screws (24%) that failed. In this group, 20 patients (38%) were satisfied with 100 points in the A-H score, 16 patients (30%) felt good, 11 patients (21%) quite good and 5 patients (9%) felt bad. DISCUSSION It is difficult to compare the stability of different types of osteosynthesis in a retrospective study because of the compliance impossibility, differences in the follow-up time and distortion of X-rays. The results are distorted in uncooperative patients, smokers, alcohol abusers and in elderly patients. CONCLUSIONS The stability of different types of osteosynthesis is almost equal - the most stable is the screw synthesis (24% probability of failure), the plates show 36% odds of failure, and the most unstable seem to be the C-nails with 42% probability of failure. However, these results do not correlate with the clinical conditions according to the A-H score. Key words: calcaneal fracture, locking plate, intramedullary nail.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    12
$a poranění kotníku $7 D016512
650    _2
$a kostní destičky $7 D001860
650    12
$a patní kost $x zranění $7 D002111
650    _2
$a ženské pohlaví $7 D005260
650    12
$a vnitřní fixace fraktury $7 D005593
650    12
$a fraktury kostí $x chirurgie $7 D050723
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a retrospektivní studie $7 D012189
650    _2
$a výsledek terapie $7 D016896
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Veselý, Radek, $d 1972- $7 mzk2011673138 $u Klinika traumatologie Lékařské fakulty Masarykovy univerzity, Úrazová nemocnice v Brně
700    1_
$a Suchomel, Radomír $7 xx0144616 $u Klinika traumatologie Lékařské fakulty Masarykovy univerzity, Úrazová nemocnice v Brně
700    1_
$a Budoš, Miroslav $7 xx0322183 $u Klinika traumatologie Lékařské fakulty Masarykovy univerzity, Úrazová nemocnice v Brně
773    0_
$w MED00011021 $t Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $x 0001-5415 $g Roč. 86, č. 2 (2019), s. 124-130
910    __
$a ABA008 $b A 8 $c 507 $y 4 $z 0
990    __
$a 20190902 $b ABA008
991    __
$a 20240905083427 $b ABA008
999    __
$a ok $b bmc $g 1442942 $s 1069290
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 86 $c 2 $d 124-130 $i 0001-5415 $m Acta chirurgiae orthopaedicae et traumatologiae Čechoslovaca $n Acta chir. orthop. traumatol. Čechoslovaca $x MED00011021
LZP    __
$b NLK118 $a Pubmed-20190902

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...