Rychlé chromatografické separace
[Fast chromatographic separation]
Lucie Borovcová, Vladimír Havlíček, Karel Lemr
Jazyk čeština Země Česko
Typ dokumentu práce podpořená grantem
- MeSH
- chromatografie kapalinová metody MeSH
- extrakce na pevné fázi MeSH
- farmakokinetika MeSH
- hmotnostní spektrometrie metody MeSH
- kontaminace léku MeSH
- kontaminace potravin analýza MeSH
- superkritická fluidní chromatografie * metody MeSH
- vysokoúčinná kapalinová chromatografie * metody MeSH
- Publikační typ
- práce podpořená grantem MeSH
Runtime is one of the essential parameters that are taken into account during development of analytical methods. Very sensitive and selective techniques based on chromatographic separation coupled with mass spectrometric detection are often utilized to meet heavy demands on the analysis of various samples. The separation time is critical during analysis of large numbers of samples or on the second column of two-dimensional chromatography. There are various approaches allowing for effective and rapid separation. These include applications of stationary phases based on fully porous particles with sub- 2 μm diameter, superficially porous particles or monolithic stationary phases. Compared to today's conventional fully porous particles (3 μm diameter and greater), higher efficiency is achieved, even at faster mobile phase flows. However, certain limitations, e.g. high working pressure (especially for sorbents with particles below 2 μm) might come into play. Furthermore, high separation efficiency provides narrow chromatographic zones, which is certainly desirable for distinguishing substances but may complicate their detection. Slow scan speed of a detector can be an issue. Ultra-high performance liquid chromatography, which is a well-established technique in analytical laboratories, is more and more often compared with previously uncommon ultra-high performance supercritical fluid chromatography. Both approaches achieve short separation times. This article presents examples of applications and mutual comparison of the mentioned techniques. Rapid chromatographic separations have become a common tool in research and control laboratories. It should be mentioned that the total duration of analysis, i.e., from sample preparation to separation and detection, followed by data interpretation, should be also considered.
Fast chromatographic separation
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19031910
- 003
- CZ-PrNML
- 005
- 20220924105756.0
- 007
- ta
- 008
- 190916s2019 xr d f 000 0|cze||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Borovcová, Lucie $u Mikrobiologický ústav AV ČR, v.v.i., Praha
- 245 10
- $a Rychlé chromatografické separace / $c Lucie Borovcová, Vladimír Havlíček, Karel Lemr
- 246 31
- $a Fast chromatographic separation
- 504 __
- $a Literatura
- 520 9_
- $a Runtime is one of the essential parameters that are taken into account during development of analytical methods. Very sensitive and selective techniques based on chromatographic separation coupled with mass spectrometric detection are often utilized to meet heavy demands on the analysis of various samples. The separation time is critical during analysis of large numbers of samples or on the second column of two-dimensional chromatography. There are various approaches allowing for effective and rapid separation. These include applications of stationary phases based on fully porous particles with sub- 2 μm diameter, superficially porous particles or monolithic stationary phases. Compared to today's conventional fully porous particles (3 μm diameter and greater), higher efficiency is achieved, even at faster mobile phase flows. However, certain limitations, e.g. high working pressure (especially for sorbents with particles below 2 μm) might come into play. Furthermore, high separation efficiency provides narrow chromatographic zones, which is certainly desirable for distinguishing substances but may complicate their detection. Slow scan speed of a detector can be an issue. Ultra-high performance liquid chromatography, which is a well-established technique in analytical laboratories, is more and more often compared with previously uncommon ultra-high performance supercritical fluid chromatography. Both approaches achieve short separation times. This article presents examples of applications and mutual comparison of the mentioned techniques. Rapid chromatographic separations have become a common tool in research and control laboratories. It should be mentioned that the total duration of analysis, i.e., from sample preparation to separation and detection, followed by data interpretation, should be also considered.
- 650 _7
- $a chromatografie kapalinová $x metody $7 D002853 $2 czmesh
- 650 _7
- $a hmotnostní spektrometrie $x metody $7 D013058 $2 czmesh
- 650 17
- $a superkritická fluidní chromatografie $x metody $7 D025924 $2 czmesh
- 650 17
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851 $2 czmesh
- 650 _7
- $a farmakokinetika $7 D010599 $2 czmesh
- 650 _7
- $a extrakce na pevné fázi $7 D052616 $2 czmesh
- 650 _7
- $a kontaminace potravin $x analýza $7 D005506 $2 czmesh
- 650 _7
- $a kontaminace léku $7 D004340 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 700 1_
- $a Havlíček, Vladimír, $d 1967- $7 jx20041110004 $u Mikrobiologický ústav AV ČR, v.v.i., Praha
- 700 1_
- $a Lemr, Karel, $d 1963- $7 ola2002157903 $u Mikrobiologický ústav AV ČR, v.v.i., Praha
- 773 0_
- $t Chemické listy $x 0009-2770 $g Roč. 113, č. 7 (2019), s. 407-414 $w MED00011010
- 856 41
- $u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/3405/3359 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y p $z 0
- 990 __
- $a 20190916152438 $b ABA008
- 991 __
- $a 20220924105748 $b ABA008
- 999 __
- $a ok $b bmc $g 1443852 $s 1070412
- BAS __
- $a 3
- BMC __
- $a 2019 $b 113 $c 7 $d 407-414 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $c NLK193 $d 20220924 $a NLK 2019-09/kv