Comparison of emissions of gaseous and particulate pollutants from the combustion of biomass and coal in modern and old-type boilers used for residential heating in the Czech Republic, Central Europe
K. Křůmal, P. Mikuška, J. Horák, F. Hopan, K. Krpec,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
- MeSH
- biomasa MeSH
- plyny chemie MeSH
- polycyklické aromatické uhlovodíky chemie MeSH
- uhlí analýza MeSH
- vytápění MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
- Evropa MeSH
The chemical composition of emissions from old-type (an overfire boiler, a boiler with down-draft combustion) and modern-type (an automatic and a gasification boiler) boilers was compared. The boilers were operated with different fuels (brown and hard coal, wet and dry wood, wood pellets and brown coal briquettes) with reduced output (40-60%). The emissions were characterized by the contents of gaseous components (NOx, SO2, CO, CO2, OGC); and particulate organic compounds (alkanes, polycyclic aromatic hydrocarbons, saccharides), including organic markers (monosaccharide anhydrides, diterpenoids, methoxyphenols, hopanes), which are used for source apportionment of particulate matter in ambient air. In general, emissions of the products of incomplete combustion (CO, particles, polycyclic aromatic hydrocarbons) were higher from the combustion of solid fuels in old-type boilers than from that in modern-type boilers. The modern-type (especially automatic) boilers were the most environmentally friendly. The highest concentrations of particulate matter (81.6-89.4 g kg-1) and particulate organic compounds (sum of PAHs: 225-275 mg kg-1) including organic markers were found in emissions from old-type (overfire) boilers, especially with the combustion of brown and hard coal. Characteristic ratios of selected organic compounds/markers applied for source identification were calculated. Computed characteristic ratios for monosaccharide anhydrides (biomass combustion) agreed with values in the literature. Homohopane indexes, frequently used for identification of coal combustion, and other characteristic ratios for PAHs, were different from the literature data. In our opinion, characteristic ratios for PAHs are not suitable for use in source apportionment.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19034576
- 003
- CZ-PrNML
- 005
- 20191008112852.0
- 007
- ta
- 008
- 191007s2019 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chemosphere.2019.04.137 $2 doi
- 035 __
- $a (PubMed)31075702
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Křůmal, Kamil $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00, Brno, Czech Republic. Electronic address: krumal@iach.cz.
- 245 10
- $a Comparison of emissions of gaseous and particulate pollutants from the combustion of biomass and coal in modern and old-type boilers used for residential heating in the Czech Republic, Central Europe / $c K. Křůmal, P. Mikuška, J. Horák, F. Hopan, K. Krpec,
- 520 9_
- $a The chemical composition of emissions from old-type (an overfire boiler, a boiler with down-draft combustion) and modern-type (an automatic and a gasification boiler) boilers was compared. The boilers were operated with different fuels (brown and hard coal, wet and dry wood, wood pellets and brown coal briquettes) with reduced output (40-60%). The emissions were characterized by the contents of gaseous components (NOx, SO2, CO, CO2, OGC); and particulate organic compounds (alkanes, polycyclic aromatic hydrocarbons, saccharides), including organic markers (monosaccharide anhydrides, diterpenoids, methoxyphenols, hopanes), which are used for source apportionment of particulate matter in ambient air. In general, emissions of the products of incomplete combustion (CO, particles, polycyclic aromatic hydrocarbons) were higher from the combustion of solid fuels in old-type boilers than from that in modern-type boilers. The modern-type (especially automatic) boilers were the most environmentally friendly. The highest concentrations of particulate matter (81.6-89.4 g kg-1) and particulate organic compounds (sum of PAHs: 225-275 mg kg-1) including organic markers were found in emissions from old-type (overfire) boilers, especially with the combustion of brown and hard coal. Characteristic ratios of selected organic compounds/markers applied for source identification were calculated. Computed characteristic ratios for monosaccharide anhydrides (biomass combustion) agreed with values in the literature. Homohopane indexes, frequently used for identification of coal combustion, and other characteristic ratios for PAHs, were different from the literature data. In our opinion, characteristic ratios for PAHs are not suitable for use in source apportionment.
- 650 _2
- $a biomasa $7 D018533
- 650 _2
- $a uhlí $x analýza $7 D003031
- 650 _2
- $a plyny $x chemie $7 D005740
- 650 _2
- $a vytápění $7 D006361
- 650 _2
- $a polycyklické aromatické uhlovodíky $x chemie $7 D011084
- 651 _2
- $a Česká republika $7 D018153
- 651 _2
- $a Evropa $7 D005060
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Mikuška, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00, Brno, Czech Republic.
- 700 1_
- $a Horák, Jiří $u Energy Research Center, VSB - Technical University of Ostrava, 17. Listopadu 15/2172, 708 33, Ostrava-Poruba, Czech Republic.
- 700 1_
- $a Hopan, František $u Energy Research Center, VSB - Technical University of Ostrava, 17. Listopadu 15/2172, 708 33, Ostrava-Poruba, Czech Republic.
- 700 1_
- $a Krpec, Kamil $u Energy Research Center, VSB - Technical University of Ostrava, 17. Listopadu 15/2172, 708 33, Ostrava-Poruba, Czech Republic.
- 773 0_
- $w MED00002124 $t Chemosphere $x 1879-1298 $g Roč. 229, č. - (2019), s. 51-59
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31075702 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191008113308 $b ABA008
- 999 __
- $a ok $b bmc $g 1451236 $s 1073126
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 229 $c - $d 51-59 $e 20190429 $i 1879-1298 $m Chemosphere $n Chemosphere $x MED00002124
- LZP __
- $a Pubmed-20191007