Multiplex real-time quantitative polymerase chain reaction assay for rapid and sensitive detection of hematopoietic chimerism
S. Nadvornikova, M. Leontovycova, K. Pegova, P. Hrabakova, R. Prerovska, H. Cechova,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
30129247
DOI
10.1111/tan.13383
Knihovny.cz E-zdroje
- MeSH
- alely MeSH
- chimérismus * MeSH
- DNA primery MeSH
- leukemie terapie MeSH
- lidé MeSH
- lokální recidiva nádoru diagnóza etiologie prevence a kontrola MeSH
- multiplexová polymerázová řetězová reakce metody MeSH
- polymerázová řetězová reakce s reverzní transkripcí metody MeSH
- polymorfismus genetický * MeSH
- transplantace hematopoetických kmenových buněk škodlivé účinky MeSH
- transplantační chiméra krev genetika MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The increase of mixed chimerism (MC) after allogeneic hematopoietic stem cell transplantation has been associated with a high risk of relapse. A variety of techniques that use polymorphic markers have been established to survey hematopoietic chimerism status. The highest sensitivity is achieved using real-time quantitative polymerase chain reaction (RQ-PCR) analysis of insertion/deletion polymorphism, which allows the detection of disease recurrence and subsequently the earlier initiation of therapeutic intervention. The purpose of this study is the evaluation of multiplex RQ-PCR for MC assessment (six biallelic genetic systems and Y-specific locus), allowing the amplification and detection of target gene of interest and glyceraldehyde-3-phosphate dehydrogenase reference housekeeping gene in a single microtube. With optimized amounts of primers and probe, the quantification of target DNA was shown to be linear throughout the tested range (100%-0.05%). The efficiencies of multiplex RQ-PCR were in a range of 0.89 to 1.07. The sensitivity of individual systems ranged 0.02% to 0.04% with an average of 0.034%. A high degree of linear correlation between the chimerism results obtained by multiplex RQ-PCR vs singleplex RQ-PCR was observed (P < 0.0001, Spearman's coefficient = 0.9927), while correlation between multiplex RQ-PCR vs short tandem repeat analysis was also statistically significant (P < 0.0001, Spearman's coefficient = 0.9769). This new multiplex RQ-PCR assay is a quick, sensitive, reproducible, and cost-effective method for accurate MC assessment.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035060
- 003
- CZ-PrNML
- 005
- 20210608141724.0
- 007
- ta
- 008
- 191007s2018 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/tan.13383 $2 doi
- 035 __
- $a (PubMed)30129247
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Nadvornikova, Sylvie $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic.
- 245 10
- $a Multiplex real-time quantitative polymerase chain reaction assay for rapid and sensitive detection of hematopoietic chimerism / $c S. Nadvornikova, M. Leontovycova, K. Pegova, P. Hrabakova, R. Prerovska, H. Cechova,
- 520 9_
- $a The increase of mixed chimerism (MC) after allogeneic hematopoietic stem cell transplantation has been associated with a high risk of relapse. A variety of techniques that use polymorphic markers have been established to survey hematopoietic chimerism status. The highest sensitivity is achieved using real-time quantitative polymerase chain reaction (RQ-PCR) analysis of insertion/deletion polymorphism, which allows the detection of disease recurrence and subsequently the earlier initiation of therapeutic intervention. The purpose of this study is the evaluation of multiplex RQ-PCR for MC assessment (six biallelic genetic systems and Y-specific locus), allowing the amplification and detection of target gene of interest and glyceraldehyde-3-phosphate dehydrogenase reference housekeeping gene in a single microtube. With optimized amounts of primers and probe, the quantification of target DNA was shown to be linear throughout the tested range (100%-0.05%). The efficiencies of multiplex RQ-PCR were in a range of 0.89 to 1.07. The sensitivity of individual systems ranged 0.02% to 0.04% with an average of 0.034%. A high degree of linear correlation between the chimerism results obtained by multiplex RQ-PCR vs singleplex RQ-PCR was observed (P < 0.0001, Spearman's coefficient = 0.9927), while correlation between multiplex RQ-PCR vs short tandem repeat analysis was also statistically significant (P < 0.0001, Spearman's coefficient = 0.9769). This new multiplex RQ-PCR assay is a quick, sensitive, reproducible, and cost-effective method for accurate MC assessment.
- 650 _2
- $a alely $7 D000483
- 650 12
- $a chimérismus $7 D046528
- 650 _2
- $a DNA primery $7 D017931
- 650 _2
- $a transplantace hematopoetických kmenových buněk $x škodlivé účinky $7 D018380
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a leukemie $x terapie $7 D007938
- 650 _2
- $a multiplexová polymerázová řetězová reakce $x metody $7 D060885
- 650 _2
- $a lokální recidiva nádoru $x diagnóza $x etiologie $x prevence a kontrola $7 D009364
- 650 12
- $a polymorfismus genetický $7 D011110
- 650 _2
- $a polymerázová řetězová reakce s reverzní transkripcí $x metody $7 D020133
- 650 _2
- $a transplantační chiméra $x krev $x genetika $7 D018183
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Leontovycova, Monika $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic.
- 700 1_
- $a Válková, Kristýna, $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic. $d 1986- $7 xx0260776
- 700 1_
- $a Hrabakova, Pavla $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic.
- 700 1_
- $a Prerovska, Renata $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic.
- 700 1_
- $a Cechova, Hana $u The Institute of Hematology and Blood Transfusion, Prague 2, Czech Republic.
- 773 0_
- $w MED00195031 $t HLA $x 2059-2310 $g Roč. 92, č. 4 (2018), s. 215-223
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30129247 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20210608141721 $b ABA008
- 999 __
- $a ok $b bmc $g 1451720 $s 1073610
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 92 $c 4 $d 215-223 $e - $i 2059-2310 $m HLA $n HLA $x MED00195031
- LZP __
- $a Pubmed-20191007