Applicability of handmade expanded polytetrafluoroethylene trileaflet-valved conduits for pulmonary valve reconstruction: An ex vivo and in vivo study
CD. Kan, JN. Wang, WL. Chen, PJ. Lu, MY. Chan, CH. Lin, WC. Hsieh,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, audiovizuální média
- MeSH
- časové faktory MeSH
- chirurgická náhrada chlopně škodlivé účinky přístrojové vybavení MeSH
- hemodynamika MeSH
- modely u zvířat MeSH
- odstranění implantátu MeSH
- plicní chlopeň patologie patofyziologie chirurgie MeSH
- polytetrafluoroethylen chemie MeSH
- protézy - design MeSH
- srdeční chlopně umělé * MeSH
- Sus scrofa MeSH
- testování materiálů MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- audiovizuální média MeSH
- časopisecké články MeSH
OBJECTIVE: The handmade expanded polytetrafluoroethylene (ePTFE) trileaflet-valved conduit could potentially be used as a substitute pulmonary valve replacement material, especially in children. The current study investigated (1) the function of the ePTFE trileaflet-valved conduits in an ex vivo experimental system and (2) the short-term performance of the conduit in a porcine model to verify its clinical applicability. METHODS: The competency of the ePTFE trileaflet-valved conduits was estimated through ex vivo (using a pulmonary mock circulation loop) and in vivo (in a porcine model with a damaged pulmonary valve) experiments. Explants were examined by gross morphology and histopathologic examination. RESULTS: In the ex vivo experiment, the ePTFE trileaflet-valved conduits were determined to effectively increase mean pulmonary pressure from 10.2 to 14.4 mm Hg compared with defective silicon-valved conduits. In addition, the regurgitation fraction value of ePTFE trileaflet-valved conduits was 15.9% to 18.1%, which was significantly better than the defective valve conduits (regurgitation fraction = 73.5%-85.7%). In the in vivo experiment, the valved conduits were confirmed to be with good valve position maintenance, and the valve and leaflets showed no signs of thickening or peeling after a short-term implantation period. There were also no significant signs of inflammation reaction on histopathologic examination. CONCLUSIONS: The ePTFE trileaflet-valved conduits for pulmonary valve reconstruction showed acceptable performance and outcomes in the ex vivo and in vivo experiments. The ePTFE trileaflet-valved conduit may be clinically useful, although additional studies in animals should be conducted to determine its long-term outcomes.
1st Faculty of Medicine Charles University Prague Czech Republic
Department of Electrical Engineering Kao Yuan University Kaohsiung Taiwan
Department of Engineering and Maintenance Kaohsiung Veterans General Hospital Kaohsiung Taiwan
Heart Science and Medical Devices Research Center National Cheng Kung University Tainan Taiwan
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035559
- 003
- CZ-PrNML
- 005
- 20191014122346.0
- 007
- ta
- 008
- 191007s2018 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jtcvs.2017.09.049 $2 doi
- 035 __
- $a (PubMed)29050816
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Kan, Chung-Dann $u Division of Cardiovascular Surgery, Department of Surgery, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan. Electronic address: kcd56@mail.ncku.edu.tw.
- 245 10
- $a Applicability of handmade expanded polytetrafluoroethylene trileaflet-valved conduits for pulmonary valve reconstruction: An ex vivo and in vivo study / $c CD. Kan, JN. Wang, WL. Chen, PJ. Lu, MY. Chan, CH. Lin, WC. Hsieh,
- 520 9_
- $a OBJECTIVE: The handmade expanded polytetrafluoroethylene (ePTFE) trileaflet-valved conduit could potentially be used as a substitute pulmonary valve replacement material, especially in children. The current study investigated (1) the function of the ePTFE trileaflet-valved conduits in an ex vivo experimental system and (2) the short-term performance of the conduit in a porcine model to verify its clinical applicability. METHODS: The competency of the ePTFE trileaflet-valved conduits was estimated through ex vivo (using a pulmonary mock circulation loop) and in vivo (in a porcine model with a damaged pulmonary valve) experiments. Explants were examined by gross morphology and histopathologic examination. RESULTS: In the ex vivo experiment, the ePTFE trileaflet-valved conduits were determined to effectively increase mean pulmonary pressure from 10.2 to 14.4 mm Hg compared with defective silicon-valved conduits. In addition, the regurgitation fraction value of ePTFE trileaflet-valved conduits was 15.9% to 18.1%, which was significantly better than the defective valve conduits (regurgitation fraction = 73.5%-85.7%). In the in vivo experiment, the valved conduits were confirmed to be with good valve position maintenance, and the valve and leaflets showed no signs of thickening or peeling after a short-term implantation period. There were also no significant signs of inflammation reaction on histopathologic examination. CONCLUSIONS: The ePTFE trileaflet-valved conduits for pulmonary valve reconstruction showed acceptable performance and outcomes in the ex vivo and in vivo experiments. The ePTFE trileaflet-valved conduit may be clinically useful, although additional studies in animals should be conducted to determine its long-term outcomes.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a odstranění implantátu $7 D020878
- 650 12
- $a srdeční chlopně umělé $7 D006350
- 650 _2
- $a chirurgická náhrada chlopně $x škodlivé účinky $x přístrojové vybavení $7 D019918
- 650 _2
- $a hemodynamika $7 D006439
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a modely u zvířat $7 D023421
- 650 _2
- $a polytetrafluoroethylen $x chemie $7 D011138
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a plicní chlopeň $x patologie $x patofyziologie $x chirurgie $7 D011664
- 650 _2
- $a Sus scrofa $7 D034421
- 650 _2
- $a časové faktory $7 D013997
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a audiovizuální média $7 D059040
- 700 1_
- $a Wang, Jieh-Neng $u Department of Pediatrics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
- 700 1_
- $a Chen, Wei-Ling $u Department of Engineering and Maintenance, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan.
- 700 1_
- $a Lu, Pong-Jeu $u Heart Science and Medical Devices Research Center, National Cheng Kung University, Tainan, Taiwan.
- 700 1_
- $a Chan, Ming-Yao $u Heart Science and Medical Devices Research Center, National Cheng Kung University, Tainan, Taiwan.
- 700 1_
- $a Lin, Chia-Hung $u Department of Electrical Engineering, Kao-Yuan University, Kaohsiung, Taiwan.
- 700 1_
- $a Hsieh, Wan-Chin $u First Faculty of Medicine, Charles University, Prague, Czech Republic.
- 773 0_
- $w MED00003020 $t The Journal of thoracic and cardiovascular surgery $x 1097-685X $g Roč. 155, č. 2 (2018), s. 765-774.e3
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29050816 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191014122810 $b ABA008
- 999 __
- $a ok $b bmc $g 1452219 $s 1074109
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 155 $c 2 $d 765-774.e3 $e 20170920 $i 1097-685X $m Journal of thoracic and cardiovascular surgery $n J Thorac Cardiovasc Surg $x MED00003020
- LZP __
- $a Pubmed-20191007