Comparison of Step Count Assessed Using Wrist- and Hip-Worn Actigraph GT3X in Free-Living Conditions in Young and Older Adults

S. Mandigout, J. Lacroix, A. Perrochon, Z. Svoboda, T. Aubourg, N. Vuillerme,

. 2019 ; 6 (-) : 252. [pub] 20191105

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19043915

Background: Walking represents a major component of physical activity (PA), and its restriction could degrade autonomy and quality of life. An important objective for preventive and/or rehabilitative strategies to improve balance and gait in normal and pathological aging conditions is to focus on physical activity. Activity monitors have recently been getting increasingly popular and represent a modern solution to measure-and communicate-PA notably in terms of steps/day. These activity monitors are well-suited for various populations as they can be worn on a variety of locations on the body, including the wrist and the hip (i.e., the two most common locations), in an undifferentiated way according to the manufacturer's instruction. The aim of this study was hence to verify potential differences in step count (SC) by comparing this parameter assessed using wrist- and hip-worn activity trackers over a 24-h period in free-living conditions in young and older adults. Methods: Young adults (n = 22) and older adults (n = 22) voluntarily participated in this study. They were required to wear two commercially-available Actigraph GT3X+ activity monitors simultaneously at two locations recommended by the manufacturer, i.e., one positioned around the wrist and one above the hip, over a 24-h period in free-living conditions. The manufacturer's software was used to obtain estimates of the SC. Results: For both groups, the wrist-worn activity tracker provided significantly higher SC than the hip-worn activity tracker did. For both placements on the body, older adults exhibited significantly lower SC than young adults. Interestingly, for both young and older participants, the difference between both measurements tended to decrease for longer distances. Conclusion: The different estimations of the step count provided by the comparison between two identical Actigraph GT3x on the wrist or the hip during the 24-h observation period in free-living conditions in young and older adults strongly suggests that caution is needed when using total step per day values as an outcome to quantify walking behavior. Probably we can suggest the same caution across implementation of different activity Tracker.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19043915
003      
CZ-PrNML
005      
20200109095115.0
007      
ta
008      
200107s2019 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/fmed.2019.00252 $2 doi
035    __
$a (PubMed)31828072
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Mandigout, Stephane $u Université de Limoges, HAVAE, EA 6310, Limoges, France.
245    10
$a Comparison of Step Count Assessed Using Wrist- and Hip-Worn Actigraph GT3X in Free-Living Conditions in Young and Older Adults / $c S. Mandigout, J. Lacroix, A. Perrochon, Z. Svoboda, T. Aubourg, N. Vuillerme,
520    9_
$a Background: Walking represents a major component of physical activity (PA), and its restriction could degrade autonomy and quality of life. An important objective for preventive and/or rehabilitative strategies to improve balance and gait in normal and pathological aging conditions is to focus on physical activity. Activity monitors have recently been getting increasingly popular and represent a modern solution to measure-and communicate-PA notably in terms of steps/day. These activity monitors are well-suited for various populations as they can be worn on a variety of locations on the body, including the wrist and the hip (i.e., the two most common locations), in an undifferentiated way according to the manufacturer's instruction. The aim of this study was hence to verify potential differences in step count (SC) by comparing this parameter assessed using wrist- and hip-worn activity trackers over a 24-h period in free-living conditions in young and older adults. Methods: Young adults (n = 22) and older adults (n = 22) voluntarily participated in this study. They were required to wear two commercially-available Actigraph GT3X+ activity monitors simultaneously at two locations recommended by the manufacturer, i.e., one positioned around the wrist and one above the hip, over a 24-h period in free-living conditions. The manufacturer's software was used to obtain estimates of the SC. Results: For both groups, the wrist-worn activity tracker provided significantly higher SC than the hip-worn activity tracker did. For both placements on the body, older adults exhibited significantly lower SC than young adults. Interestingly, for both young and older participants, the difference between both measurements tended to decrease for longer distances. Conclusion: The different estimations of the step count provided by the comparison between two identical Actigraph GT3x on the wrist or the hip during the 24-h observation period in free-living conditions in young and older adults strongly suggests that caution is needed when using total step per day values as an outcome to quantify walking behavior. Probably we can suggest the same caution across implementation of different activity Tracker.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Lacroix, Justine $u Université de Limoges, HAVAE, EA 6310, Limoges, France.
700    1_
$a Perrochon, Anaick $u Université de Limoges, HAVAE, EA 6310, Limoges, France.
700    1_
$a Svoboda, Zdenek $u Faculty of Physical Culture, Palacky University Olomouc, Olomouc, Czechia.
700    1_
$a Aubourg, Timothee $u Univ. Grenoble Alpes, AGEIS, Grenoble, France. Orange Labs, Meylan, France.
700    1_
$a Vuillerme, Nicolas $u Univ. Grenoble Alpes, AGEIS, Grenoble, France. Institut Universitaire de France, Paris, France.
773    0_
$w MED00188756 $t Frontiers in medicine $x 2296-858X $g Roč. 6, č. - (2019), s. 252
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31828072 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200107 $b ABA008
991    __
$a 20200109095444 $b ABA008
999    __
$a ind $b bmc $g 1480504 $s 1082585
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 6 $c - $d 252 $e 20191105 $i 2296-858X $m Frontiers in medicine $n Front. med. $x MED00188756
LZP    __
$a Pubmed-20200107

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...