Reliability of a measurement technique for achilles tendon length

J. Skypala, D. Jandacka, J. Hamill,

. 2019 ; 37 (20) : 2389-2395. [pub] 20190625

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19044725

Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19044725
003      
CZ-PrNML
005      
20200115111616.0
007      
ta
008      
200109s2019 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1080/02640414.2019.1635375 $2 doi
035    __
$a (PubMed)31238805
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Skypala, Jiri $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic.
245    10
$a Reliability of a measurement technique for achilles tendon length / $c J. Skypala, D. Jandacka, J. Hamill,
520    9_
$a Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.
650    _2
$a Achillova šlacha $x anatomie a histologie $x diagnostické zobrazování $7 D000125
650    _2
$a dospělí $7 D000328
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a fotogrammetrie $7 D010780
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a ultrasonografie $7 D014463
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jandacka, Daniel $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic.
700    1_
$a Hamill, Joseph $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic. b Department of Kinesiology, University of Massachusetts , Amherst , USA.
773    0_
$w MED00002949 $t Journal of sports sciences $x 1466-447X $g Roč. 37, č. 20 (2019), s. 2389-2395
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31238805 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200109 $b ABA008
991    __
$a 20200115111949 $b ABA008
999    __
$a ok $b bmc $g 1482994 $s 1083398
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 37 $c 20 $d 2389-2395 $e 20190625 $i 1466-447X $m Journal of sports sciences $n J Sports Sci $x MED00002949
LZP    __
$a Pubmed-20200109

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...