Reliability of a measurement technique for achilles tendon length
J. Skypala, D. Jandacka, J. Hamill,
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články
- MeSH
- Achillova šlacha anatomie a histologie diagnostické zobrazování MeSH
- dospělí MeSH
- fotogrammetrie MeSH
- lidé MeSH
- mladý dospělý MeSH
- reprodukovatelnost výsledků MeSH
- ultrasonografie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19044725
- 003
- CZ-PrNML
- 005
- 20200115111616.0
- 007
- ta
- 008
- 200109s2019 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1080/02640414.2019.1635375 $2 doi
- 035 __
- $a (PubMed)31238805
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Skypala, Jiri $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic.
- 245 10
- $a Reliability of a measurement technique for achilles tendon length / $c J. Skypala, D. Jandacka, J. Hamill,
- 520 9_
- $a Recently, there has been an increasing amount of literature dealing with new methods of Achilles tendon (AT) length measurement. However, most of these studies measured the AT length between the calcaneus and medial head of the gastrocnemius and the reliability of such a measurement has not been satisfactorily presented. The purpose of this study was to determine the reliability of the measurement of AT length within and between sessions. AT length was measured by using a combination of ultrasound imaging and optoelectronic stereophotogrammetry. Nineteen healthy athletes visited the lab on six different days where the AT length was measured on both lower extremities: 1) from the calcaneus to the mid-point of the medial and lateral heads of the gastrocnemius; and 2) from the calcaneus to the soleus musculotendinous attachment. The reliability results indicated high intraclass correlation coefficients (ICC > 0.8), a low typical error (< 0.6) and a standard error of measurement (SEM < 5.5 mm) for all measured AT lengths on within and between sessions. This non-invasive reliable measurement method may be recommended for sport science research purposes.
- 650 _2
- $a Achillova šlacha $x anatomie a histologie $x diagnostické zobrazování $7 D000125
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a fotogrammetrie $7 D010780
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a ultrasonografie $7 D014463
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Jandacka, Daniel $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic.
- 700 1_
- $a Hamill, Joseph $u a Department of Human Movement Studies, Human Motion Diagnostics Center, University of Ostrava , Ostrava , Czech Republic. b Department of Kinesiology, University of Massachusetts , Amherst , USA.
- 773 0_
- $w MED00002949 $t Journal of sports sciences $x 1466-447X $g Roč. 37, č. 20 (2019), s. 2389-2395
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31238805 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20200115111949 $b ABA008
- 999 __
- $a ok $b bmc $g 1482994 $s 1083398
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 37 $c 20 $d 2389-2395 $e 20190625 $i 1466-447X $m Journal of sports sciences $n J Sports Sci $x MED00002949
- LZP __
- $a Pubmed-20200109