• Je něco špatně v tomto záznamu ?

Evaluation of superficially porous particle based zwitterionic chiral ion exchangers against fully porous particle benchmarks for enantioselective ultra-high performance liquid chromatography

C. Geibel, K. Dittrich, U. Woiwode, M. Kohout, T. Zhang, W. Lindner, M. Lämmerhofer,

. 2019 ; 1603 (-) : 130-140. [pub] 20190614

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19044731

Zwitterionic chiral ion-exchange selectors (ZWIX) obtained by conjugation of quinine and 2-aminocyclohexanesulfonic acid via a carbamate bond were immobilized on three different silica particle types, viz. 120 Å 3 μm fully porous particles (FPP), 200 Å 3 μm FPP and 160 Å 2.7 μm superficially porous particles (SPP). Selector densities were determined by elemental analysis and the porosities of packed columns measured by inverse size exclusion chromatography with polystyrene standards. Liquid chromatographic tests with a set of chiral zwitterionic, acidic and basic analytes showed that the surface chemistry was successfully transferred to the distinct particle morphologies. The chromatographic performance of the three columns was evaluated by acquiring van Deemter curves. The results showed that the column packed with the SPP particles gives the best performance and kinetic plots further demonstrated that they represent the most favorable compromise in terms of speed, efficiency and pressure drop. Sub-minute separations could be accomplished at much lower pressure drop on the core-shell column, e.g. 2-amino-2-phenylbutyric acid was baseline separated in less than 15 s on a 5 cm long column. The Maxwell effective medium theory with second order approximation was applied to calculate effective diffusion in the mesoporous zones of SPP and FPP, which allowed eventually to deconvolute the individual peak dispersion contributions (ha, hb, hc,m, hc,s, hc,ads). The efficiency gain of the 160 Å SPP column compared to the 120 Å FPP (benchmark) column was mainly due to lower eddies (ha), smaller c-term accounting for slow adsorption-desorption kinetics in enantioselective chromatography (hc,ads), and also due to lower stationary mass transfer resistance (hc,s). Enhanced effective diffusion (Deff) in the SPP column contributed to a lower longitudinal diffusion (hb). In contrast, the mobile phase mass transfer coefficient was similar in the two columns leading to comparable hc,m contributions. This study discloses some options for improvement of the efficiency of ZWIX-type chiral columns such as replacing narrow pore (120 Å) by wide pore (200 Å) particles, substituting FPP by SPP and reducing the selector density on the surface.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19044731
003      
CZ-PrNML
005      
20200115090739.0
007      
ta
008      
200109s2019 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2019.06.026 $2 doi
035    __
$a (PubMed)31235330
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Geibel, Christian $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
245    10
$a Evaluation of superficially porous particle based zwitterionic chiral ion exchangers against fully porous particle benchmarks for enantioselective ultra-high performance liquid chromatography / $c C. Geibel, K. Dittrich, U. Woiwode, M. Kohout, T. Zhang, W. Lindner, M. Lämmerhofer,
520    9_
$a Zwitterionic chiral ion-exchange selectors (ZWIX) obtained by conjugation of quinine and 2-aminocyclohexanesulfonic acid via a carbamate bond were immobilized on three different silica particle types, viz. 120 Å 3 μm fully porous particles (FPP), 200 Å 3 μm FPP and 160 Å 2.7 μm superficially porous particles (SPP). Selector densities were determined by elemental analysis and the porosities of packed columns measured by inverse size exclusion chromatography with polystyrene standards. Liquid chromatographic tests with a set of chiral zwitterionic, acidic and basic analytes showed that the surface chemistry was successfully transferred to the distinct particle morphologies. The chromatographic performance of the three columns was evaluated by acquiring van Deemter curves. The results showed that the column packed with the SPP particles gives the best performance and kinetic plots further demonstrated that they represent the most favorable compromise in terms of speed, efficiency and pressure drop. Sub-minute separations could be accomplished at much lower pressure drop on the core-shell column, e.g. 2-amino-2-phenylbutyric acid was baseline separated in less than 15 s on a 5 cm long column. The Maxwell effective medium theory with second order approximation was applied to calculate effective diffusion in the mesoporous zones of SPP and FPP, which allowed eventually to deconvolute the individual peak dispersion contributions (ha, hb, hc,m, hc,s, hc,ads). The efficiency gain of the 160 Å SPP column compared to the 120 Å FPP (benchmark) column was mainly due to lower eddies (ha), smaller c-term accounting for slow adsorption-desorption kinetics in enantioselective chromatography (hc,ads), and also due to lower stationary mass transfer resistance (hc,s). Enhanced effective diffusion (Deff) in the SPP column contributed to a lower longitudinal diffusion (hb). In contrast, the mobile phase mass transfer coefficient was similar in the two columns leading to comparable hc,m contributions. This study discloses some options for improvement of the efficiency of ZWIX-type chiral columns such as replacing narrow pore (120 Å) by wide pore (200 Å) particles, substituting FPP by SPP and reducing the selector density on the surface.
650    _2
$a adsorpce $7 D000327
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
650    _2
$a iontoměniče $x chemie $7 D007475
650    _2
$a kinetika $7 D007700
650    _2
$a poréznost $7 D016062
650    _2
$a stereoizomerie $7 D013237
650    _2
$a teplota $7 D013696
655    _2
$a časopisecké články $7 D016428
700    1_
$a Dittrich, Kristina $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
700    1_
$a Woiwode, Ulrich $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany.
700    1_
$a Kohout, Michal $u Department of Organic Chemistry, University of Chemistry and Technology, Prague, Czech Republic.
700    1_
$a Zhang, Tong $u Chiral Technologies Europe, 160 Boulevard Gonthier d'Andernach, 67400 Illkirch, Graffenstaden, France.
700    1_
$a Lindner, Wolfgang $u Lindner Consulting GmbH, Ziegelofengasse 37, 3400 Klosterneuburg, Austria; Institute of Analytical Chemistry, University of Vienna, Waehringerstrasse 38, 1090 Vienna, Austria.
700    1_
$a Lämmerhofer, Michael $u Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany. Electronic address: michael.laemmerhofer@uni-tuebingen.de.
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1603, č. - (2019), s. 130-140
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31235330 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200109 $b ABA008
991    __
$a 20200115091112 $b ABA008
999    __
$a ok $b bmc $g 1483000 $s 1083404
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 1603 $c - $d 130-140 $e 20190614 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20200109

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...