-
Je něco špatně v tomto záznamu ?
Effect of High-Induction Magnetic Stimulation on Elasticity of the Patellar Tendon
J. Prucha, V. Socha, V. Sochova, L. Hanakova, S. Stojic,
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NV16-28784A
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
NLK
PubMed Central
od 2016
Europe PubMed Central
od 2016
Open Access Digital Library
od 2010-01-01
Open Access Digital Library
od 2010-01-01
Open Access Digital Library
od 2016-01-01
Medline Complete (EBSCOhost)
od 2015-12-01 do 2023-06-29
Wiley-Blackwell Open Access Titles
od 2010
ROAD: Directory of Open Access Scholarly Resources
od 2010
PubMed
30154991
DOI
10.1155/2018/7172034
Knihovny.cz E-zdroje
- MeSH
- algoritmy MeSH
- biofyzika MeSH
- dospělí MeSH
- elastografie * MeSH
- lidé středního věku MeSH
- lidé MeSH
- ligamentum patellae diagnostické zobrazování MeSH
- pevnost ve smyku MeSH
- pohyb MeSH
- pružnost MeSH
- rehabilitace metody MeSH
- ultrasonografie * MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Nowadays, a high-induction magnetic stimulation is starting to be increasingly applied as a biophysical stimulation in the conservative treatment of the degenerative locomotor system diseases. These are mainly in correlation with the changes in soft tissue elasticity, which should be positively influenced by the flow-induced electrical currents of high current density during high-induction magnetic stimulation. This assumption was verified within the interventional and prospective study using the ultrasound elastography. The group consisted of 6 volunteers, whose elasticity of the patellar tendons was measured using the 2D shear-wave ultrasound elastography. The volunteers were then exposed to a 20-minute high-induction magnetic stimulation session with a frequency of 20 Hz, in 2 s package intervals, with a 5 s pause, and a induced electric current density of 100 Am-2 in the tendons area. A tendon tension was measured five times for all volunteers, where mean tension at the marked area of the tendon, as well as the highest point tension indicated by the Q-Box, was monitored. The measurement results show that high-induction magnetic stimulation has an influence on the patellar tendon tension change, which occurred in the case of all involved volunteers when the patellar tension was decreased.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19045274
- 003
- CZ-PrNML
- 005
- 20200113082005.0
- 007
- ta
- 008
- 200109s2018 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1155/2018/7172034 $2 doi
- 035 __
- $a (PubMed)30154991
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Prucha, Jaroslav $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Sitna Sq. 3105, 272 01 Kladno, Czech Republic.
- 245 10
- $a Effect of High-Induction Magnetic Stimulation on Elasticity of the Patellar Tendon / $c J. Prucha, V. Socha, V. Sochova, L. Hanakova, S. Stojic,
- 520 9_
- $a Nowadays, a high-induction magnetic stimulation is starting to be increasingly applied as a biophysical stimulation in the conservative treatment of the degenerative locomotor system diseases. These are mainly in correlation with the changes in soft tissue elasticity, which should be positively influenced by the flow-induced electrical currents of high current density during high-induction magnetic stimulation. This assumption was verified within the interventional and prospective study using the ultrasound elastography. The group consisted of 6 volunteers, whose elasticity of the patellar tendons was measured using the 2D shear-wave ultrasound elastography. The volunteers were then exposed to a 20-minute high-induction magnetic stimulation session with a frequency of 20 Hz, in 2 s package intervals, with a 5 s pause, and a induced electric current density of 100 Am-2 in the tendons area. A tendon tension was measured five times for all volunteers, where mean tension at the marked area of the tendon, as well as the highest point tension indicated by the Q-Box, was monitored. The measurement results show that high-induction magnetic stimulation has an influence on the patellar tendon tension change, which occurred in the case of all involved volunteers when the patellar tension was decreased.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a biofyzika $7 D001703
- 650 _2
- $a pružnost $7 D004548
- 650 12
- $a elastografie $7 D054459
- 650 _2
- $a zdraví dobrovolníci pro lékařské studie $7 D064368
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a pohyb $7 D009068
- 650 _2
- $a ligamentum patellae $x diagnostické zobrazování $7 D017847
- 650 _2
- $a rehabilitace $x metody $7 D012046
- 650 _2
- $a pevnost ve smyku $7 D033081
- 650 12
- $a ultrasonografie $7 D014463
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Socha, Vladimir $u Laboratory of Human Factors and Automation in Aviation, Czech Technical University in Prague, Horska 3, 128 03 Prague, Czech Republic.
- 700 1_
- $a Sochova, Viera $u Soreha Ltd., Rehabilitation Clinic at Moldava nad Bodvou, Postupimska 27, 040 22 Kosice, Slovakia.
- 700 1_
- $a Hanakova, Lenka $u Laboratory of Human Factors and Automation in Aviation, Czech Technical University in Prague, Horska 3, 128 03 Prague, Czech Republic.
- 700 1_
- $a Stojic, Slobodan $u Laboratory of Human Factors and Automation in Aviation, Czech Technical University in Prague, Horska 3, 128 03 Prague, Czech Republic.
- 773 0_
- $w MED00196657 $t Journal of healthcare engineering $x 2040-2295 $g Roč. 2018, č. - (2018), s. 7172034
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30154991 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20200113082337 $b ABA008
- 999 __
- $a ok $b bmc $g 1483543 $s 1083947
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 2018 $c - $d 7172034 $e 20180801 $i 2040-2295 $m Journal of healthcare engineering $n J Healthc Eng $x MED00196657
- GRA __
- $a NV16-28784A $p MZ0
- LZP __
- $a Pubmed-20200109