Analysis of diffusion tensor measurements of the human cervical spinal cord based on semiautomatic segmentation of the white and gray matter
M. Dostál, M. Keřkovský, E. Korit Áková, E. Němcová, J. Stulík, M. Staňková, V. Bernard,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
AZV-15-32133A
Czech Health Research Council - International
MUNI/A/1464/2014
Grant Agency of Masaryk University - International
NV15-32133A
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
NLK
Medline Complete (EBSCOhost)
od 2012-01-01 do Před 1 rokem
Wiley Free Content
od 1999 do Před 5 lety
PubMed
29707834
DOI
10.1002/jmri.26166
Knihovny.cz E-zdroje
- MeSH
- algoritmy MeSH
- anizotropie MeSH
- bílá hmota diagnostické zobrazování MeSH
- difuzní magnetická rezonance * MeSH
- dospělí MeSH
- echoplanární zobrazování * MeSH
- krční mícha diagnostické zobrazování MeSH
- lidé MeSH
- mladý dospělý MeSH
- odchylka pozorovatele MeSH
- počítačové zpracování obrazu metody MeSH
- poranění míchy diagnostické zobrazování MeSH
- prospektivní studie MeSH
- šedá hmota diagnostické zobrazování MeSH
- strojové učení MeSH
- zobrazování difuzních tenzorů * MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Segmentation of the gray and white matter (GM, WM) of the human spinal cord in MRI images as well as the analysis of spinal cord diffusivity are challenging. When appropriately segmented, diffusion tensor imaging (DTI) of the spinal cord might be beneficial in the diagnosis and prognosis of several diseases. PURPOSE: To evaluate the applicability of a semiautomatic algorithm provided by ITK-SNAP in classification mode (CLASS) for segmenting cervical spinal cord GM, WM in MRI images and analyzing DTI parameters. STUDY TYPE: Prospective. SUBJECTS: Twenty healthy volunteers. SEQUENCES: 1.5T, turbo spin echo, fast field echo, single-shot echo planar imaging. ASSESSMENT: Three raters segmented the tissues by manual, CLASS, and atlas-based methods (Spinal Cord Toolbox, SCT) on T2 -weighted and DTI images. Masks were quantified by similarity and distance metrics, then analyzed for repeatability and mutual comparability. Masks created over T2 images were registered into diffusion space and fractional anisotropy (FA) values were statistically evaluated for dependency on method, rater, or tissue. STATISTICAL TESTS: t-test, analysis of variance (ANOVA), coefficient of variation, Dice coefficient, Hausdorff distance. RESULTS: CLASS segmentation reached better agreement with manual segmentation than did SCT (P < 0.001). Intra- and interobserver repeatability of SCT was better for GM and WM (both P < 0.001) but comparable with CLASS in entire spinal cord segmentation (P = 0.17 and P = 0.07, respectively). While FA values of whole spinal cord were not influenced by choice of segmentation method, both semiautomatic methods yielded lower FA values (P < 0.005) for GM than did the manual technique (mean differences 0.02 and 0.04 for SCT and CLASS, respectively). Repeatability of FA values for all methods was sufficient, with mostly less than 2% variance. DATA CONCLUSION: The presented semiautomatic method in combination with the proposed approach to data registration and analyses of spinal cord diffusivity can potentially be used as an alternative to atlas-based segmentation. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1217-1227.
Department of Biophysics Faculty of Medicine Masaryk University Brno Czech Republic
Department of Radiology University Hospital Brno and Masaryk University Brno Czech Republic
Institute of Biostatistics and Analyses Faculty of Medicine Masaryk University Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19045472
- 003
- CZ-PrNML
- 005
- 20200115101602.0
- 007
- ta
- 008
- 200109s2018 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jmri.26166 $2 doi
- 035 __
- $a (PubMed)29707834
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Dostál, Marek $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno, Czech Republic. Department of Radiology, University Hospital Brno and Masaryk University, Brno, Czech Republic.
- 245 10
- $a Analysis of diffusion tensor measurements of the human cervical spinal cord based on semiautomatic segmentation of the white and gray matter / $c M. Dostál, M. Keřkovský, E. Korit Áková, E. Němcová, J. Stulík, M. Staňková, V. Bernard,
- 520 9_
- $a BACKGROUND: Segmentation of the gray and white matter (GM, WM) of the human spinal cord in MRI images as well as the analysis of spinal cord diffusivity are challenging. When appropriately segmented, diffusion tensor imaging (DTI) of the spinal cord might be beneficial in the diagnosis and prognosis of several diseases. PURPOSE: To evaluate the applicability of a semiautomatic algorithm provided by ITK-SNAP in classification mode (CLASS) for segmenting cervical spinal cord GM, WM in MRI images and analyzing DTI parameters. STUDY TYPE: Prospective. SUBJECTS: Twenty healthy volunteers. SEQUENCES: 1.5T, turbo spin echo, fast field echo, single-shot echo planar imaging. ASSESSMENT: Three raters segmented the tissues by manual, CLASS, and atlas-based methods (Spinal Cord Toolbox, SCT) on T2 -weighted and DTI images. Masks were quantified by similarity and distance metrics, then analyzed for repeatability and mutual comparability. Masks created over T2 images were registered into diffusion space and fractional anisotropy (FA) values were statistically evaluated for dependency on method, rater, or tissue. STATISTICAL TESTS: t-test, analysis of variance (ANOVA), coefficient of variation, Dice coefficient, Hausdorff distance. RESULTS: CLASS segmentation reached better agreement with manual segmentation than did SCT (P < 0.001). Intra- and interobserver repeatability of SCT was better for GM and WM (both P < 0.001) but comparable with CLASS in entire spinal cord segmentation (P = 0.17 and P = 0.07, respectively). While FA values of whole spinal cord were not influenced by choice of segmentation method, both semiautomatic methods yielded lower FA values (P < 0.005) for GM than did the manual technique (mean differences 0.02 and 0.04 for SCT and CLASS, respectively). Repeatability of FA values for all methods was sufficient, with mostly less than 2% variance. DATA CONCLUSION: The presented semiautomatic method in combination with the proposed approach to data registration and analyses of spinal cord diffusivity can potentially be used as an alternative to atlas-based segmentation. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1217-1227.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a anizotropie $7 D016880
- 650 _2
- $a krční mícha $x diagnostické zobrazování $7 D066193
- 650 12
- $a difuzní magnetická rezonance $7 D038524
- 650 12
- $a zobrazování difuzních tenzorů $7 D056324
- 650 12
- $a echoplanární zobrazování $7 D017352
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a šedá hmota $x diagnostické zobrazování $7 D066128
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 _2
- $a strojové učení $7 D000069550
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a odchylka pozorovatele $7 D015588
- 650 _2
- $a prospektivní studie $7 D011446
- 650 _2
- $a poranění míchy $x diagnostické zobrazování $7 D013119
- 650 _2
- $a bílá hmota $x diagnostické zobrazování $7 D066127
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Keřkovský, Miloš $u Department of Radiology, University Hospital Brno and Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Korit Áková, Eva $u Institute of Biostatistics and Analyses, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Němcová, Eva $u Department of Radiology, University Hospital Brno and Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Stulík, Jakub $u Department of Radiology, University Hospital Brno and Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Staňková, Monika $u Department of Radiology, University Hospital Brno and Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Bernard, Vladan $u Department of Biophysics, Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 773 0_
- $w MED00004911 $t Journal of magnetic resonance imaging : JMRI $x 1522-2586 $g Roč. 48, č. 5 (2018), s. 1217-1227
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29707834 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20200109 $b ABA008
- 991 __
- $a 20200115101935 $b ABA008
- 999 __
- $a ok $b bmc $g 1483741 $s 1084145
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 48 $c 5 $d 1217-1227 $e 20180429 $i 1522-2586 $m Journal of magnetic resonance imaging $n J Magn Reson Imaging $x MED00004911
- GRA __
- $a AZV-15-32133A $p Czech Health Research Council $2 International
- GRA __
- $a MUNI/A/1464/2014 $p Grant Agency of Masaryk University $2 International
- GRA __
- $a NV15-32133A $p MZ0
- LZP __
- $a Pubmed-20200109