Je něco špatně v tomto záznamu ?
The influence of purification of carp collagen used in a novel composite graft with sandwich construction of the wall on its biological properties and graft patency rates
P. Mitas, T. Grus, L. Lambert, M. Mlcek, H. Chlup, E. Honsova, M. Dohnalova, T. Suchy, A. Burgetova, J. Lindner, M. Spacek
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- arteriae carotides chirurgie fyziologie MeSH
- cévní protézy MeSH
- kapři MeSH
- kolagen aplikace a dávkování izolace a purifikace MeSH
- ovce MeSH
- protézy - design metody trendy MeSH
- průchodnost cév fyziologie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
We compared graft outcome between two types of a novel composite three-layer carp-collagen-coated vascular graft in low-flow conditions in a sheep model. Collagen in group A underwent more cycles of purification than in group B in order to increase the ratio between collagen and residual fat. The grafts were implanted end-to-side in both carotid arteries in sheep (14 grafts in 7 sheep in group A, 18 grafts in 9 sheep in group B) and artificially stenosed on the right side. The flow in the grafts in group A decreased from 297±118 ml/min to 158±159 ml/min (p=0.041) after placement of the artificial stenosis in group A, and from 330±164ml/min to 97±29 ml/min (p=0.0052) in group B (p=0.27 between the groups). From the five surviving animals in group A, both grafts occluded in one animal 3 and 14 days after implantation. In group B, from the six surviving animals, only one graft on the left side remained patent (p=0.0017). Histology showed degradation of the intimal layer in the center with endothelization from the periphery in group A and formation of thick fibrous intimal layer in group B. We conclude that the ratio between collagen and lipid content in the novel three-layer graft plays a critical role in its patency and structural changes in vivo.
Department Pathology Institute for Clinical and Experimental Medicine Prague Czech Republic
Institute of Physiology 1st Faculty of Medicine Charles University Prague Czech Republic
Institute of Rock Structure and Mechanics of the Czech Academy of Sciences Prague Czech Republic
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20005478
- 003
- CZ-PrNML
- 005
- 20200603084607.0
- 007
- ta
- 008
- 200511s2019 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.934117 $2 doi
- 035 __
- $a (PubMed)31177797
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Mitáš, Petr $7 xx0158090 $u Second Department of Surgery - Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
- 245 14
- $a The influence of purification of carp collagen used in a novel composite graft with sandwich construction of the wall on its biological properties and graft patency rates / $c P. Mitas, T. Grus, L. Lambert, M. Mlcek, H. Chlup, E. Honsova, M. Dohnalova, T. Suchy, A. Burgetova, J. Lindner, M. Spacek
- 504 __
- $a Literatura
- 520 9_
- $a We compared graft outcome between two types of a novel composite three-layer carp-collagen-coated vascular graft in low-flow conditions in a sheep model. Collagen in group A underwent more cycles of purification than in group B in order to increase the ratio between collagen and residual fat. The grafts were implanted end-to-side in both carotid arteries in sheep (14 grafts in 7 sheep in group A, 18 grafts in 9 sheep in group B) and artificially stenosed on the right side. The flow in the grafts in group A decreased from 297±118 ml/min to 158±159 ml/min (p=0.041) after placement of the artificial stenosis in group A, and from 330±164ml/min to 97±29 ml/min (p=0.0052) in group B (p=0.27 between the groups). From the five surviving animals in group A, both grafts occluded in one animal 3 and 14 days after implantation. In group B, from the six surviving animals, only one graft on the left side remained patent (p=0.0017). Histology showed degradation of the intimal layer in the center with endothelization from the periphery in group A and formation of thick fibrous intimal layer in group B. We conclude that the ratio between collagen and lipid content in the novel three-layer graft plays a critical role in its patency and structural changes in vivo.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a cévní protézy $7 D001807
- 650 _2
- $a arteriae carotides $x chirurgie $x fyziologie $7 D002339
- 650 _2
- $a kapři $7 D002347
- 650 _2
- $a kolagen $x aplikace a dávkování $x izolace a purifikace $7 D003094
- 650 _2
- $a protézy - design $x metody $x trendy $7 D011474
- 650 _2
- $a ovce $7 D012756
- 650 _2
- $a průchodnost cév $x fyziologie $7 D014654
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Grus, Tomáš, $d 1974- $7 xx0080427 $u Second Department of Surgery - Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
- 700 1_
- $a Lambert, Lukáš $7 xx0145830 $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Institute of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Chlup, Hynek $7 xx0210944 $u Department of Mechanics, Biomechanics and Mechatronics, Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague, Czech Republic
- 700 1_
- $a Honsová, Eva, $d 1956- $7 xx0075648 $u Department Pathology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Dohnalová, Michaela $7 _AN049544 $u Second Department of Surgery - Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
- 700 1_
- $a Suchý, Tomáš $7 xx0144648 $u Institute of Rock Structure and Mechanics of the Czech Academy of Sciences, Prague, Czech Republic
- 700 1_
- $a Burgetová, Andrea $7 xx0163957 $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 700 1_
- $a Lindner, Jaroslav, $d 1957- $7 mzk2005269705 $u Second Department of Surgery - Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
- 700 1_
- $a Špaček, Miroslav $7 xx0160372 $u Second Department of Surgery - Department of Cardiovascular Surgery, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 68, č. 4 (2019), s. 603-610
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31177797 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20200511 $b ABA008
- 991 __
- $a 20200601132209 $b ABA008
- 999 __
- $a ok $b bmc $g 1530832 $s 1095533
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 68 $c 4 $d 603-610 $e 20190606 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- LZP __
- $b NLK118 $a Pubmed-20200511