Je něco špatně v tomto záznamu ?
Electrode movement prevention - an animal model
V. Masopust, I. Petríková, M. Mlček, J. Holubová, R. Rokyta, J. Fricová, K. Janoušková
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- implantované elektrody normy MeSH
- migrace cizích těles diagnóza prevence a kontrola MeSH
- modely u zvířat * MeSH
- počítačové zpracování obrazu metody MeSH
- prasata MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Electrode migration is the most common complication of spinal cord stimulation (SCS). The problem of longitudinal migration has already been solved, but lateral migration remains the most common current complication. The present article describes new electrodes fixation opportunities for the reduction of lateral migration in SCS. The pig was chosen as an animal model to illustrate a new protocol of electrode fixation for the control of lateral and longitudinal migration. The displacement of the electrode was measured using two different optical methods: the digital image stereo-correlation and the digital image processing methods. Fixation with two anchors has always considerably reduced electrode displacement and when fixation is done with two anchors and a loop then lateral migration is reduced by 62.5 % and longitudinal migration is reduced by 94.1 %. It was shown that the results are significantly different at the alpha=0.001 significance level. Based on a statistical evaluation it is possible to state that the differences between experimental results obtained for three different protocols of lead fixation are statistically significant and we can recommend the new fixation method for common practice.
Department of Otorhinolaryngology Central Military Hospital Prague Czech Republic
Department of Physiology 1st Faculty of Medicine Charles University Prague Czech Republic
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20005486
- 003
- CZ-PrNML
- 005
- 20200609140747.0
- 007
- ta
- 008
- 200511s2019 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933997 $2 doi
- 035 __
- $a (PubMed)31177789
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Masopust, Václav $7 xx0061196 $u Department of neurosurgery and neurooncoogy, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 245 10
- $a Electrode movement prevention - an animal model / $c V. Masopust, I. Petríková, M. Mlček, J. Holubová, R. Rokyta, J. Fricová, K. Janoušková
- 504 __
- $a Literatura
- 520 9_
- $a Electrode migration is the most common complication of spinal cord stimulation (SCS). The problem of longitudinal migration has already been solved, but lateral migration remains the most common current complication. The present article describes new electrodes fixation opportunities for the reduction of lateral migration in SCS. The pig was chosen as an animal model to illustrate a new protocol of electrode fixation for the control of lateral and longitudinal migration. The displacement of the electrode was measured using two different optical methods: the digital image stereo-correlation and the digital image processing methods. Fixation with two anchors has always considerably reduced electrode displacement and when fixation is done with two anchors and a loop then lateral migration is reduced by 62.5 % and longitudinal migration is reduced by 94.1 %. It was shown that the results are significantly different at the alpha=0.001 significance level. Based on a statistical evaluation it is possible to state that the differences between experimental results obtained for three different protocols of lead fixation are statistically significant and we can recommend the new fixation method for common practice.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a implantované elektrody $x normy $7 D004567
- 650 _2
- $a migrace cizích těles $x diagnóza $x prevence a kontrola $7 D005548
- 650 _2
- $a počítačové zpracování obrazu $x metody $7 D007091
- 650 12
- $a modely u zvířat $7 D023421
- 650 _2
- $a prasata $7 D013552
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Petríková, Iva $7 xx0033184 $u Department of Applied Mechanics, Faculty of Mechanical Engineering, Technical University of Liberec, Liberec, Czech Republic
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453 $u Department of Physiology, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Holubová, Jana $7 xx0239449 $u Department of Otorhinolaryngology, Central Military Hospital, Prague, Czech Republic
- 700 1_
- $a Rokyta, Richard, $d 1938- $7 nlk19990073780 $u Department of Normal, Pathological and Clinical Physiology, Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Fricová, Jitka, $d 1971- $7 xx0105524 $u Department of Normal, Pathological and Clinical Physiology, Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Janoušková, Karla $7 xx0248433 $u Department of Otorhinolaryngology, Central Military Hospital, Prague, Czech Republic
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 68, č. 4 (2019), s. 667-673
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31177789 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20200511 $b ABA008
- 991 __
- $a 20200609140743 $b ABA008
- 999 __
- $a ok $b bmc $g 1530840 $s 1095541
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 68 $c 4 $d 667-673 $e 20190606 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- LZP __
- $b NLK118 $a Pubmed-20200511