Je něco špatně v tomto záznamu ?
Comparative study of capillary filtration coefficient (Kfc) determination by a manual and automatic perfusion system. Step by step technique review
C. C. Bravo-Reyna, G. Torres-Villalobos, N. Aguilar-Blas, J. Frías-Guillén, J. R. Guerra-Mora
Jazyk angličtina Země Česko
Typ dokumentu srovnávací studie, časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- arteria pulmonalis fyziologie MeSH
- kapilární permeabilita fyziologie MeSH
- kapiláry fyziologie MeSH
- krysa rodu rattus MeSH
- orgánové kultury - kultivační techniky MeSH
- perfuze přístrojové vybavení metody MeSH
- plicní tlak v zaklínění fyziologie MeSH
- potkani Wistar MeSH
- venae pulmonales fyziologie MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
The purpose of calculating the capillary filtration coefficient is to experimentally evaluate edema formation in models of pulmonary ischemia-reperfusion injury. For many years, the obtaining of this coefficient implies a series of manual maneuvers during ex-vivo reperfusion of pulmonary arterial pressure, venous pressure and weight, as well as the calculation of the Kfc formula. Through automation, the calculation of capillary filtration coefficient could be easier and more efficient. To describe an automatic method designed in our laboratory to calculating the capillary filtration coefficient and compare with traditional determination of capillary filtration coefficient as gold standard method. An automatic three valve perfusion system was constructed, commanded by a mastery module connected to a graphical user interface. To test its accuracy, cardiopulmonary blocks of Wistar rats were harvested and distributed in manual (n=8) and automated (n=8) capillary filtration coefficient determination groups. Physiological parameters as pulmonary arterial pressure, pulmonary venous pressure, weight and capillary filtration coefficient were obtained. Results: Capillary filtration coefficient, pulmonary arterial pressure, venous arterial pressure shown no statistical significance difference between the groups. The automated perfusion system for obtaining Kfc was standardized and validated, giving reliable results without biases and making the process more efficient in terms of time and personal staff.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20010273
- 003
- CZ-PrNML
- 005
- 20200720141435.0
- 007
- ta
- 008
- 200707s2019 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.933971 $2 doi
- 035 __
- $a (PubMed)31711294
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Bravo-Reyna, C. C. $u Experimental Surgery Department, National Institute of Medical Sciences and Nutrition "Salvador Zubirán", Mexico City, Mexico
- 245 10
- $a Comparative study of capillary filtration coefficient (Kfc) determination by a manual and automatic perfusion system. Step by step technique review / $c C. C. Bravo-Reyna, G. Torres-Villalobos, N. Aguilar-Blas, J. Frías-Guillén, J. R. Guerra-Mora
- 504 __
- $a Literatura
- 520 9_
- $a The purpose of calculating the capillary filtration coefficient is to experimentally evaluate edema formation in models of pulmonary ischemia-reperfusion injury. For many years, the obtaining of this coefficient implies a series of manual maneuvers during ex-vivo reperfusion of pulmonary arterial pressure, venous pressure and weight, as well as the calculation of the Kfc formula. Through automation, the calculation of capillary filtration coefficient could be easier and more efficient. To describe an automatic method designed in our laboratory to calculating the capillary filtration coefficient and compare with traditional determination of capillary filtration coefficient as gold standard method. An automatic three valve perfusion system was constructed, commanded by a mastery module connected to a graphical user interface. To test its accuracy, cardiopulmonary blocks of Wistar rats were harvested and distributed in manual (n=8) and automated (n=8) capillary filtration coefficient determination groups. Physiological parameters as pulmonary arterial pressure, pulmonary venous pressure, weight and capillary filtration coefficient were obtained. Results: Capillary filtration coefficient, pulmonary arterial pressure, venous arterial pressure shown no statistical significance difference between the groups. The automated perfusion system for obtaining Kfc was standardized and validated, giving reliable results without biases and making the process more efficient in terms of time and personal staff.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a kapiláry $x fyziologie $7 D002196
- 650 _2
- $a kapilární permeabilita $x fyziologie $7 D002199
- 650 _2
- $a orgánové kultury - kultivační techniky $7 D009924
- 650 _2
- $a perfuze $x přístrojové vybavení $x metody $7 D010477
- 650 _2
- $a arteria pulmonalis $x fyziologie $7 D011651
- 650 _2
- $a venae pulmonales $x fyziologie $7 D011667
- 650 _2
- $a plicní tlak v zaklínění $x fyziologie $7 D011669
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a potkani Wistar $7 D017208
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Torres-Villalobos, G. $u Experimental Surgery Department, National Institute of Medical Sciences and Nutrition “Salvador Zubirán”, Mexico City, Mexico
- 700 1_
- $a Aguilar-Blas, N. $u Experimental Surgery Department, National Institute of Medical Sciences and Nutrition “Salvador Zubirán”, Mexico City, Mexico
- 700 1_
- $a Frías-Guillén, J. $u Experimental Surgery Department, National Institute of Medical Sciences and Nutrition “Salvador Zubirán”, Mexico City, Mexico
- 700 1_
- $a Guerra-Mora, J. R. $u Experimental Surgery Department, National Institute of Medical Sciences and Nutrition “Salvador Zubirán”, Mexico City, Mexico; Functional Neuroscience Unit, Mexico City, Mexico
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 68, č. 6 (2019), s. 901-908
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31711294 $y Pubmed
- 910 __
- $a ABA008 $b A 4120 $c 266 $y p $z 0
- 990 __
- $a 20200707 $b ABA008
- 991 __
- $a 20200709130733 $b ABA008
- 999 __
- $a ok $b bmc $g 1545932 $s 1100365
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 68 $c 6 $d 901-908 $e 20191025 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- LZP __
- $b NLK118 $a Pubmed-20200707