• Je něco špatně v tomto záznamu ?

Genotoxicity of environmental air pollution in three European cities: Prague, Kosice and Sofia

A. Gábelová, Z. Valovicová, E. Horváthová, D. Slamenová, B. Binková, RJ. Srám, PB. Farmer,

. 2004 ; 563 (1) : 49-59. [pub] 2004Sep12

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20013847

The genotoxic potential of extractable organic matter (EOM) associated with the respirable particulate matter (PM <10 microm) of atmospheric pollution has been determined in three European cities--Prague (Czech Republic, two monitoring sites, Libus and Smíchov), Kosice (Slovak Republic) and Sofia (Bulgaria) using the alkaline single-cell gel electrophoresis (the comet assay). The EOM samples were extracted by dichloromethane from ambient airborne particles collected daily (24 h intervals) during 3-month sampling periods in winter and summer seasons. The human metabolically competent cell line Hep G2 was used as a test system and benzo[a]pyrene (BaP), a known carcinogen, was applied as a positive control (internal standard) in each electrophoretic run. Two-hour exposure of Hep G2 cells to equivalent EOM concentrations ranging from 5 to 150 microg EOM/ml resulted in a linear dose-dependent increase of DNA migration (r > 0.9, P < 0.01). A less significant dose-response (r = 0.61) was only induced by the EOM sample from the locality Prague-Libus (PRG-LB) in the winter. Generally, a 1.5 to four-fold increase of DNA strand breaks over the background control level was determined in EOM-exposed cells. In order to compare the genotoxic potential of individual EOMs, a mathematical model was used to correct the 'real' data. No substantial location- or season-related differences were found in EOM genotoxicity (EOM microg/ml), except for the EOM sample from Sofia, collected in the summer. This EOM sample induced a nearly two-fold lower level of DNA damage in comparison with other EOMs. On the other hand, clear statistically significant location- and season-related differences (P < 0.001) in ambient air genotoxicity were determined when the EOM quantity per cubic meter of air (microg/m3) was taken into account. In that case, the genotoxicity of winter air pollution was six- to 10-fold higher in comparison with summer air. The air pollution genotoxicity in individual localities rose during the winter season in the order: PRG-LB < Kosice < Prague-Smíchov (PRG-SM) < Sofia, while during the summer season the highest ambient air genotoxicity was revealed in the locality Prague-Smíchov and approximately equal air pollution genotoxicity was determined among localities Prague-Libus, Kosice and Sofia (PRG-LB approximately Kosice approximately Sofia < PRG-SM). The greatest overall air pollution genotoxicity was determined in the locality Sofia during the winter season. In a time course study to evaluate the kinetics of DNA strand break rejoining it was shown that the level of DNA strand breaks in EOM-exposed cells has returned to near the background level within 24 h after the treatment.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20013847
003      
CZ-PrNML
005      
20200923101201.0
007      
ta
008      
200911s2004 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.mrgentox.2004.05.014 $2 doi
035    __
$a (PubMed)15324748
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Gábelová, Alena $u Laboratory of Mutagenesis and Carcinogenesis, Cancer Research Institute of the Slovak Academy of Sciences, Bratislava, Slovak Republic. alena.gabelova@savba.sk
245    10
$a Genotoxicity of environmental air pollution in three European cities: Prague, Kosice and Sofia / $c A. Gábelová, Z. Valovicová, E. Horváthová, D. Slamenová, B. Binková, RJ. Srám, PB. Farmer,
520    9_
$a The genotoxic potential of extractable organic matter (EOM) associated with the respirable particulate matter (PM <10 microm) of atmospheric pollution has been determined in three European cities--Prague (Czech Republic, two monitoring sites, Libus and Smíchov), Kosice (Slovak Republic) and Sofia (Bulgaria) using the alkaline single-cell gel electrophoresis (the comet assay). The EOM samples were extracted by dichloromethane from ambient airborne particles collected daily (24 h intervals) during 3-month sampling periods in winter and summer seasons. The human metabolically competent cell line Hep G2 was used as a test system and benzo[a]pyrene (BaP), a known carcinogen, was applied as a positive control (internal standard) in each electrophoretic run. Two-hour exposure of Hep G2 cells to equivalent EOM concentrations ranging from 5 to 150 microg EOM/ml resulted in a linear dose-dependent increase of DNA migration (r > 0.9, P < 0.01). A less significant dose-response (r = 0.61) was only induced by the EOM sample from the locality Prague-Libus (PRG-LB) in the winter. Generally, a 1.5 to four-fold increase of DNA strand breaks over the background control level was determined in EOM-exposed cells. In order to compare the genotoxic potential of individual EOMs, a mathematical model was used to correct the 'real' data. No substantial location- or season-related differences were found in EOM genotoxicity (EOM microg/ml), except for the EOM sample from Sofia, collected in the summer. This EOM sample induced a nearly two-fold lower level of DNA damage in comparison with other EOMs. On the other hand, clear statistically significant location- and season-related differences (P < 0.001) in ambient air genotoxicity were determined when the EOM quantity per cubic meter of air (microg/m3) was taken into account. In that case, the genotoxicity of winter air pollution was six- to 10-fold higher in comparison with summer air. The air pollution genotoxicity in individual localities rose during the winter season in the order: PRG-LB < Kosice < Prague-Smíchov (PRG-SM) < Sofia, while during the summer season the highest ambient air genotoxicity was revealed in the locality Prague-Smíchov and approximately equal air pollution genotoxicity was determined among localities Prague-Libus, Kosice and Sofia (PRG-LB approximately Kosice approximately Sofia < PRG-SM). The greatest overall air pollution genotoxicity was determined in the locality Sofia during the winter season. In a time course study to evaluate the kinetics of DNA strand break rejoining it was shown that the level of DNA strand breaks in EOM-exposed cells has returned to near the background level within 24 h after the treatment.
650    _2
$a látky znečišťující vzduch $x toxicita $7 D000393
650    12
$a znečištění ovzduší $7 D000397
650    _2
$a benzopyren $x toxicita $7 D001564
650    _2
$a karcinogeny $x toxicita $7 D002273
650    _2
$a nádorové buněčné linie $7 D045744
650    12
$a velkoměsta $7 D002947
650    _2
$a kometový test $7 D020552
650    _2
$a DNA $x účinky léků $7 D004247
650    _2
$a poškození DNA $7 D004249
650    _2
$a oprava DNA $7 D004260
650    _2
$a lidé $7 D006801
650    _2
$a testy genotoxicity $7 D009152
650    _2
$a mutageny $x toxicita $7 D009153
650    _2
$a organické látky $x toxicita $7 D009930
650    _2
$a roční období $7 D012621
651    _2
$a Česká republika $7 D018153
651    _2
$a Bulharsko $7 D002031
651    _2
$a Slovenská republika $7 D018154
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Valovicová, Zuzana
700    1_
$a Horváthová, Eva
700    1_
$a Slamenová, Darina
700    1_
$a Binková, Blanka
700    1_
$a Srám, Radim J
700    1_
$a Farmer, Peter B
773    0_
$w MED00003430 $t Mutation research $x 0027-5107 $g Roč. 563, č. 1 (2004), s. 49-59
856    41
$u https://pubmed.ncbi.nlm.nih.gov/15324748 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200911 $b ABA008
991    __
$a 20200923101158 $b ABA008
999    __
$a ok $b bmc $g 1563292 $s 1104004
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2004 $b 563 $c 1 $d 49-59 $e 2004Sep12 $i 0027-5107 $m Mutation research $n Mutat Res $x MED00003430
LZP    __
$a Pubmed-20200911

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...