Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X-ray microtomography
Miroslav Jiřík, Martin Bartoš, Petr Tomášek, Anna Malečková, Tomáš Kural, Jana Horáková, David Lukáš, Tomáš Suchý, Petra Kochová, Marie Hubálek Kalbáčová, Milena Králíčková, Zbyněk Tonar
Language English Country United States
Document type Research Support, Non-U.S. Gov't
Grant support
NV15-25813A
MZ0
CEP Register
Digital library NLK
Full text - Article
Source
NLK
Medline Complete (EBSCOhost)
from 2012-06-01 to 1 year ago
PubMed
29476582
DOI
10.1002/jemt.23011
Knihovny.cz E-resources
- MeSH
- Biocompatible Materials analysis MeSH
- Surface Properties MeSH
- X-Ray Microtomography methods MeSH
- Software MeSH
- Materials Testing * methods MeSH
- Imaging, Three-Dimensional MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans.
Biomedical Center Faculty of Medicine in Pilsen Charles University Pilsen 323 00 Czech Republic
Faculty of Textile Engineering Technical University of Liberec Liberec 1 461 17 Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20016103
- 003
- CZ-PrNML
- 005
- 20240617085739.0
- 007
- ta
- 008
- 201015s2018 xxu f 000 0|eng||
- 009
- AR
- 024 0_
- $a 10.1002/jemt.23011 $2 DOI
- 035 __
- $a (Pubmed)29476582
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Jiřík, Miroslav $7 mzk2016922454 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic
- 245 10
- $a Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X-ray microtomography / $c Miroslav Jiřík, Martin Bartoš, Petr Tomášek, Anna Malečková, Tomáš Kural, Jana Horáková, David Lukáš, Tomáš Suchý, Petra Kochová, Marie Hubálek Kalbáčová, Milena Králíčková, Zbyněk Tonar
- 520 9_
- $a Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans.
- 650 _7
- $a biokompatibilní materiály $x analýza $7 D001672 $2 czmesh
- 650 17
- $a testování materiálů $x metody $7 D008422 $2 czmesh
- 650 _7
- $a rentgenová mikrotomografie $x metody $7 D055114 $2 czmesh
- 650 _7
- $a zobrazování trojrozměrné $7 D021621 $2 czmesh
- 650 _7
- $a software $7 D012984 $2 czmesh
- 650 _7
- $a povrchové vlastnosti $7 D013499 $2 czmesh
- 655 _7
- $a práce podpořená grantem $7 D013485 $2 czmesh
- 700 1_
- $a Bartoš, Martin $7 xx0239638 $u Institute of Dental Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague 2, 128 01, Czech Republic
- 700 1_
- $a Tomášek, Petr $7 xx0268978 $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
- 700 1_
- $a Malečková, Anna $7 xx0228871 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
- 700 1_
- $a Kural, Tomáš, $d 1963- $7 xx0104846 $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
- 700 1_
- $a Horáková, Jana $7 xx0227823 $u Faculty of Textile Engineering, Technical University of Liberec, Liberec 1, 461 17, Czech Republic
- 700 1_
- $a Lukáš, David, $d 1958- $7 xx0000188 $u Faculty of Textile Engineering, Technical University of Liberec, Liberec 1, 461 17, Czech Republic
- 700 1_
- $a Suchý, Tomáš $u Department of Composites and Carbon Materials, Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, Prague 8, Czech Republic
- 700 1_
- $a Kochová, Petra $7 _AN047718 $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, Pilsen, 306 14, Czech Republic
- 700 1_
- $a Hubálek Kalbáčová, Marie $7 xx0119193 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Institute of Pathological Physiology, First Faculty of Medicine, Charles University, U nemocnice 5, 128 53, Prague, Czech Republic
- 700 1_
- $a Králíčková, Milena $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
- 700 1_
- $a Tonar, Zbyněk, $d 1976- $7 xx0074224 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
- 773 0_
- $t Microscopy research and technique $x 1059-910X $g Roč. 81, č. 6 (2018), s. 551-568 $w MED00003348
- 910 __
- $a ABA008 $y 0 $z 0
- 990 __
- $a 20201015123752 $b ABA008
- 991 __
- $a 20240617085740 $b ABA008
- 999 __
- $a kom $b bmc $g 1572890 $s 1106275
- BAS __
- $a 3
- BMC __
- $a 2018 $b 81 $c 6 $d 551-568 $x MED00003348 $i 1059-910X $m Microscopy research and technique
- GRA __
- $a NV15-25813A $p MZ0
- LZP __
- $c NLK120 $d 20240617 $a 2020-grant