Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X-ray microtomography

Miroslav Jiřík, Martin Bartoš, Petr Tomášek, Anna Malečková, Tomáš Kural, Jana Horáková, David Lukáš, Tomáš Suchý, Petra Kochová, Marie Hubálek Kalbáčová, Milena Králíčková, Zbyněk Tonar

. 2018 ; 81 (6) : 551-568.

Language English Country United States

Document type Research Support, Non-U.S. Gov't

Grant support
NV15-25813A MZ0 CEP Register

Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20016103
003      
CZ-PrNML
005      
20240617085739.0
007      
ta
008      
201015s2018 xxu f 000 0|eng||
009      
AR
024    0_
$a 10.1002/jemt.23011 $2 DOI
035    __
$a (Pubmed)29476582
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Jiřík, Miroslav $7 mzk2016922454 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic
245    10
$a Generating standardized image data for testing and calibrating quantification of volumes, surfaces, lengths, and object counts in fibrous and porous materials using X-ray microtomography / $c Miroslav Jiřík, Martin Bartoš, Petr Tomášek, Anna Malečková, Tomáš Kural, Jana Horáková, David Lukáš, Tomáš Suchý, Petra Kochová, Marie Hubálek Kalbáčová, Milena Králíčková, Zbyněk Tonar
520    9_
$a Quantification of the structure and composition of biomaterials using micro-CT requires image segmentation due to the low contrast and overlapping radioopacity of biological materials. The amount of bias introduced by segmentation procedures is generally unknown. We aim to develop software that generates three-dimensional models of fibrous and porous structures with known volumes, surfaces, lengths, and object counts in fibrous materials and to provide a software tool that calibrates quantitative micro-CT assessments. Virtual image stacks were generated using the newly developed software TeIGen, enabling the simulation of micro-CT scans of unconnected tubes, connected tubes, and porosities. A realistic noise generator was incorporated. Forty image stacks were evaluated using micro-CT, and the error between the true known and estimated data was quantified. Starting with geometric primitives, the error of the numerical estimation of surfaces and volumes was eliminated, thereby enabling the quantification of volumes and surfaces of colliding objects. Analysis of the sensitivity of the thresholding upon parameters of generated testing image sets revealed the effects of decreasing resolution and increasing noise on the accuracy of the micro-CT quantification. The size of the error increased with decreasing resolution when the voxel size exceeded 1/10 of the typical object size, which simulated the effect of the smallest details that could still be reliably quantified. Open-source software for calibrating quantitative micro-CT assessments by producing and saving virtually generated image data sets with known morphometric data was made freely available to researchers involved in morphometry of three-dimensional fibrillar and porous structures in micro-CT scans.
650    _7
$a biokompatibilní materiály $x analýza $7 D001672 $2 czmesh
650    17
$a testování materiálů $x metody $7 D008422 $2 czmesh
650    _7
$a rentgenová mikrotomografie $x metody $7 D055114 $2 czmesh
650    _7
$a zobrazování trojrozměrné $7 D021621 $2 czmesh
650    _7
$a software $7 D012984 $2 czmesh
650    _7
$a povrchové vlastnosti $7 D013499 $2 czmesh
655    _7
$a práce podpořená grantem $7 D013485 $2 czmesh
700    1_
$a Bartoš, Martin $7 xx0239638 $u Institute of Dental Medicine, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague 2, 128 01, Czech Republic
700    1_
$a Tomášek, Petr $7 xx0268978 $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
700    1_
$a Malečková, Anna $7 xx0228871 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
700    1_
$a Kural, Tomáš, $d 1963- $7 xx0104846 $u Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
700    1_
$a Horáková, Jana $7 xx0227823 $u Faculty of Textile Engineering, Technical University of Liberec, Liberec 1, 461 17, Czech Republic
700    1_
$a Lukáš, David, $d 1958- $7 xx0000188 $u Faculty of Textile Engineering, Technical University of Liberec, Liberec 1, 461 17, Czech Republic
700    1_
$a Suchý, Tomáš $u Department of Composites and Carbon Materials, Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, Prague 8, Czech Republic
700    1_
$a Kochová, Petra $7 _AN047718 $u European Centre of Excellence NTIS, Faculty of Applied Sciences, University of West Bohemia, Univerzitní 22, Pilsen, 306 14, Czech Republic
700    1_
$a Hubálek Kalbáčová, Marie $7 xx0119193 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Institute of Pathological Physiology, First Faculty of Medicine, Charles University, U nemocnice 5, 128 53, Prague, Czech Republic
700    1_
$a Králíčková, Milena $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
700    1_
$a Tonar, Zbyněk, $d 1976- $7 xx0074224 $u Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Pilsen, 323 00, Czech Republic ; Department of Histology and Embryology, Faculty of Medicine in Pilsen, Charles University in Prague, Pilsen, 301 66, Czech Republic
773    0_
$t Microscopy research and technique $x 1059-910X $g Roč. 81, č. 6 (2018), s. 551-568 $w MED00003348
910    __
$a ABA008 $y 0 $z 0
990    __
$a 20201015123752 $b ABA008
991    __
$a 20240617085740 $b ABA008
999    __
$a kom $b bmc $g 1572890 $s 1106275
BAS    __
$a 3
BMC    __
$a 2018 $b 81 $c 6 $d 551-568 $x MED00003348 $i 1059-910X $m Microscopy research and technique
GRA    __
$a NV15-25813A $p MZ0
LZP    __
$c NLK120 $d 20240617 $a 2020-grant

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...