Proteomická analýza vzorků kondenzátu vydechovaného vzduchu prokázala vysokou reprodukovatelnost hmotnostně spektrometrických měření
[Proteomic analysis of exhaled breath condensate samples showed high reproducibility of mass spectrometric measurements]

J. Václavková, P. Kouřilová, J. Vrbková, D. Holub, M. Hajdúch, P. Džubák

. 2020 ; 114 (7) : 470-479.

Language Czech Country Czech Republic

Document type Review

Grant support
NV16-32302A MZ0 CEP Register

Exhaled breath condensate is considered a rich source of biomarkers that can provide valuable information for early diagnosis of respiratory and systemic diseases. However, exhaled breath condensate (EBC) consists mainly of water vapor and the concentration of analytes in the exhaled breath condensate sample is very low, close to the detection limit of sensitive methods such as mass spectrometry. Here, we have developed a mass spectrometry-based approach to characterize the EBC proteome. We compared biological and technical replicates of the measured samples, compared the protein profile between individual samples of healthy individuals and described the reproducibility between the three technical replicates of the sample taken. We have found that repeated measurements of samples are reproducible and can increase the number of proteins identified. Analysis led to the detection of 2797 unique proteins in all samples. Based on statistical analysis, it was shown that the 10% difference from the mean is due more to the deviation of the mass spectrometry measurements than to the biological variability of the samples. And second, the change in protein amount below 20% of the average in the case of EBC is due to method variability and should not be considered a significant change in protein expression using label-free mass spectrometry techniques.

Proteomic analysis of exhaled breath condensate samples showed high reproducibility of mass spectrometric measurements

Bibliography, etc.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc20019492
003      
CZ-PrNML
005      
20240625091350.0
007      
ta
008      
201119s2020 xr ad f 000 0|cze||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Václavková, Jana $7 xx0313552 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
245    10
$a Proteomická analýza vzorků kondenzátu vydechovaného vzduchu prokázala vysokou reprodukovatelnost hmotnostně spektrometrických měření / $c J. Václavková, P. Kouřilová, J. Vrbková, D. Holub, M. Hajdúch, P. Džubák
246    31
$a Proteomic analysis of exhaled breath condensate samples showed high reproducibility of mass spectrometric measurements
504    __
$a Literatura
520    9_
$a Exhaled breath condensate is considered a rich source of biomarkers that can provide valuable information for early diagnosis of respiratory and systemic diseases. However, exhaled breath condensate (EBC) consists mainly of water vapor and the concentration of analytes in the exhaled breath condensate sample is very low, close to the detection limit of sensitive methods such as mass spectrometry. Here, we have developed a mass spectrometry-based approach to characterize the EBC proteome. We compared biological and technical replicates of the measured samples, compared the protein profile between individual samples of healthy individuals and described the reproducibility between the three technical replicates of the sample taken. We have found that repeated measurements of samples are reproducible and can increase the number of proteins identified. Analysis led to the detection of 2797 unique proteins in all samples. Based on statistical analysis, it was shown that the 10% difference from the mean is due more to the deviation of the mass spectrometry measurements than to the biological variability of the samples. And second, the change in protein amount below 20% of the average in the case of EBC is due to method variability and should not be considered a significant change in protein expression using label-free mass spectrometry techniques.
650    12
$a vzduch $7 D000388
650    _2
$a dýchání ústy $7 D009058
650    _2
$a vydechnutí $7 D045853
650    _2
$a proteomika $x metody $7 D040901
655    _2
$a přehledy $7 D016454
700    1_
$a Kouřilová, Pavla $7 xx0319227 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
700    1_
$a Vrbková, Jana $7 _AN085567 $u .Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
700    1_
$a Holub, Dušan $7 xx0169439 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
700    1_
$a Hajdúch, Marián, $d 1969- $7 xx0050218 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
700    1_
$a Džubák, Petr $7 xx0080445 $u Laboratoř experimentální medicíny, Ústav molekulární a translační medicíny, Lékařská fakulta, Univerzita Palackého v Olomouci, Olomouc
773    0_
$t Chemické listy $x 0009-2770 $g Roč. 114, č. 7 (2020), s. 470-479 $w MED00011010
856    41
$u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/3641/3578 $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y p $z 0
990    __
$a 20201117145639 $b ABA008
991    __
$a 20240625091346 $b ABA008
999    __
$a ok $b bmc $g 1584412 $s 1109690
BAS    __
$a 3
BMC    __
$a 2020 $b 114 $c 7 $d 470-479 $i 0009-2770 $m Chemické listy $x MED00011010
GRA    __
$a NV16-32302A $p MZ0
LZP    __
$c NLK197 $d 20210818 $a NLK 2020-42/dk

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...