• Je něco špatně v tomto záznamu ?

Dialysis of one sample drop on-line connected with electrophoresis in short capillary

F. Opekar, P. Tůma,

. 2020 ; 219 (-) : 121252. [pub] 20200613

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20021583

An analytical apparatus is described, based on on-line connection of electrophoresis in a short capillary with a dialysis unit enabling dialysis in micro-litre sample volumes into submicro-litre volumes of an acceptor solution in a dialysing fibre. After a defined dialysis time, the dialysate from the dialysing fibre is injected into a separation capillary through an air-assisted flow-gating interface cast from PDMS. In the flow-gating injection space, the exit from the delivery capillary bringing the dialysate is placed directly opposite the entrance into the separation capillary at a distance of 380 μm. In order to enable injection of a very small volume of dialysate, the background electrolyte is forced out of the injection space with air before the injection, so that a drop of dialysate with a volume of about 0.1 μL is formed between the exit from the delivery and the entrance into the separation capillary; the dialysate is injected hydrodynamically from this dialysate drop. Then the injection space is filled with the background electrolyte and the separation is commenced. The basic properties of the apparatus were tested on model mixtures of inorganic cations (K+, Ba2+ and Na+) and organic molecules (creatinine, histidine and arginine). The applicability to real samples was tested on the determination of basic amino acids (histidine, lysine and arginine) in a blood serum sample.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20021583
003      
CZ-PrNML
005      
20201204092345.0
007      
ta
008      
201125s2020 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2020.121252 $2 doi
035    __
$a (PubMed)32887143
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Opekar, František $u Charles University, Faculty of Science, Department of Analytical Chemistry, Albertov 2030, 128 43, Prague 2, Czech Republic. Electronic address: frantisek.opekar@natur.cuni.cz.
245    10
$a Dialysis of one sample drop on-line connected with electrophoresis in short capillary / $c F. Opekar, P. Tůma,
520    9_
$a An analytical apparatus is described, based on on-line connection of electrophoresis in a short capillary with a dialysis unit enabling dialysis in micro-litre sample volumes into submicro-litre volumes of an acceptor solution in a dialysing fibre. After a defined dialysis time, the dialysate from the dialysing fibre is injected into a separation capillary through an air-assisted flow-gating interface cast from PDMS. In the flow-gating injection space, the exit from the delivery capillary bringing the dialysate is placed directly opposite the entrance into the separation capillary at a distance of 380 μm. In order to enable injection of a very small volume of dialysate, the background electrolyte is forced out of the injection space with air before the injection, so that a drop of dialysate with a volume of about 0.1 μL is formed between the exit from the delivery and the entrance into the separation capillary; the dialysate is injected hydrodynamically from this dialysate drop. Then the injection space is filled with the background electrolyte and the separation is commenced. The basic properties of the apparatus were tested on model mixtures of inorganic cations (K+, Ba2+ and Na+) and organic molecules (creatinine, histidine and arginine). The applicability to real samples was tested on the determination of basic amino acids (histidine, lysine and arginine) in a blood serum sample.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Tůma, Petr $u Charles University, Third Faculty of Medicine, Department of Hygiene, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address: petr.tuma@lf3.cuni.cz.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 219, č. - (2020), s. 121252
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32887143 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201204092343 $b ABA008
999    __
$a ind $b bmc $g 1591293 $s 1112255
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 219 $c - $d 121252 $e 20200613 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...