-
Something wrong with this record ?
Influence of slice thickness on result of CT histogram analysis in indeterminate adrenal masses
Z. Tüdös, P. Kučera, P. Szász, I. Hartmann, K. Langová, J. Škarda, F. Čtvrtlík,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
Grant support
17-31847A
Ministerstvo Zdravotnictví Ceské Republiky - International
NV17-31847A
MZ0
CEP Register
Digital library NLK
Full text - Article
NLK
ProQuest Central
from 2016 to 1 year ago
Medline Complete (EBSCOhost)
from 2016-01-01 to 1 year ago
Nursing & Allied Health Database (ProQuest)
from 2000-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2000-01-01 to 1 year ago
- MeSH
- Adrenocortical Adenoma diagnostic imaging MeSH
- Diagnosis, Differential MeSH
- Adult MeSH
- Pheochromocytoma diagnostic imaging MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Adrenal Gland Neoplasms diagnostic imaging MeSH
- Tomography, X-Ray Computed methods MeSH
- Predictive Value of Tests MeSH
- Retrospective Studies MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Sensitivity and Specificity MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
PURPOSE: The aim was to determine the optimal slice thickness of CT images and the optimal threshold of negative voxels for CT histogram analysis to distinguish adrenal adenomas from non-adenomas with a mean attenuation more than 10 Hounsfield units (HU). METHODS: Volume CT histogram analysis of 83 lipid-poor adenomas and 80 non-adenomas was performed retrospectively. The volume of interest was extracted from each adrenal lesion, and the mean attenuation, standard deviation (SD), and percentage of voxels with a negative CT value were recorded using reconstructions with different slice thicknesses (5 mm, 2.5 mm, 1.25 mm). The percentage of negative voxels was correlated with SD as a measure of image noise and with the reference splenic tissue values. The sensitivity, specificity, and positive predictive value (PPV) for the identification of adenomas were calculated using reconstructions with different slice thicknesses and three different thresholds of negative voxels (1%, 5%, 10%). RESULTS: The percentage of negative voxels increased with a thinner slice thickness and correlated with increasing CT image noise in adenomas, non-adenomas, and spleen. Using a threshold of 10% negative voxels and a slice thickness of 5 mm, we reached a sensitivity of 53.0%, specificity of 98.8% and the highest PPV, and thus we propose this combination for clinical use. Other combinations achieved a clearly lower specificity and PPV as a result of the increasing noise in CT images. CONCLUSION: The CT slice thickness significantly affects the result and diagnostic value of histogram analysis. Thin CT slice reconstructions are inappropriate for histogram analysis.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20022788
- 003
- CZ-PrNML
- 005
- 20201214124817.0
- 007
- ta
- 008
- 201125s2019 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00261-018-1835-2 $2 doi
- 035 __
- $a (PubMed)30460531
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Tüdös, Zbyněk $u Department of Radiology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, I. P. Pavlova 6, 77900, Olomouc, Czech Republic.
- 245 10
- $a Influence of slice thickness on result of CT histogram analysis in indeterminate adrenal masses / $c Z. Tüdös, P. Kučera, P. Szász, I. Hartmann, K. Langová, J. Škarda, F. Čtvrtlík,
- 520 9_
- $a PURPOSE: The aim was to determine the optimal slice thickness of CT images and the optimal threshold of negative voxels for CT histogram analysis to distinguish adrenal adenomas from non-adenomas with a mean attenuation more than 10 Hounsfield units (HU). METHODS: Volume CT histogram analysis of 83 lipid-poor adenomas and 80 non-adenomas was performed retrospectively. The volume of interest was extracted from each adrenal lesion, and the mean attenuation, standard deviation (SD), and percentage of voxels with a negative CT value were recorded using reconstructions with different slice thicknesses (5 mm, 2.5 mm, 1.25 mm). The percentage of negative voxels was correlated with SD as a measure of image noise and with the reference splenic tissue values. The sensitivity, specificity, and positive predictive value (PPV) for the identification of adenomas were calculated using reconstructions with different slice thicknesses and three different thresholds of negative voxels (1%, 5%, 10%). RESULTS: The percentage of negative voxels increased with a thinner slice thickness and correlated with increasing CT image noise in adenomas, non-adenomas, and spleen. Using a threshold of 10% negative voxels and a slice thickness of 5 mm, we reached a sensitivity of 53.0%, specificity of 98.8% and the highest PPV, and thus we propose this combination for clinical use. Other combinations achieved a clearly lower specificity and PPV as a result of the increasing noise in CT images. CONCLUSION: The CT slice thickness significantly affects the result and diagnostic value of histogram analysis. Thin CT slice reconstructions are inappropriate for histogram analysis.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a nádory nadledvin $x diagnostické zobrazování $7 D000310
- 650 _2
- $a adenom kůry nadledvin $x diagnostické zobrazování $7 D018246
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 _2
- $a diferenciální diagnóza $7 D003937
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a feochromocytom $x diagnostické zobrazování $7 D010673
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 _2
- $a retrospektivní studie $7 D012189
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Kučera, Petr $u Department of Radiology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, I. P. Pavlova 6, 77900, Olomouc, Czech Republic.
- 700 1_
- $a Szász, Paulína $u Department of Radiology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, I. P. Pavlova 6, 77900, Olomouc, Czech Republic.
- 700 1_
- $a Hartmann, Igor $u Department of Urology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, I. P. Pavlova 6, 77900, Olomouc, Czech Republic.
- 700 1_
- $a Langová, Kateřina $u Department of Medical Biophysics, Faculty of Medicine and Dentistry, Palacky University, Hněvotínská 3, Olomouc, 775 15, Czech Republic.
- 700 1_
- $a Škarda, Jozef $u Department of Clinical and Molecular Pathology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, Hněvotínská 3, 775 15, Olomouc, Czech Republic.
- 700 1_
- $a Čtvrtlík, Filip $u Department of Radiology, University Hospital and Faculty of Medicine and Dentistry, Palacky University, I. P. Pavlova 6, 77900, Olomouc, Czech Republic. filip.ctvrtlik@fnol.cz.
- 773 0_
- $w MED00194920 $t Abdominal radiology (New York) $x 2366-0058 $g Roč. 44, č. 4 (2019), s. 1461-1469
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30460531 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201214124817 $b ABA008
- 999 __
- $a ok $b bmc $g 1595107 $s 1113464
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 44 $c 4 $d 1461-1469 $e - $i 2366-0058 $m Abdominal radiology $n Abdom Radiol (NY) $x MED00194920
- GRA __
- $a 17-31847A $p Ministerstvo Zdravotnictví Ceské Republiky $2 International
- GRA __
- $a NV17-31847A $p MZ0
- LZP __
- $a Pubmed-20201125