-
Something wrong with this record ?
Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study
M. Černíková, J. Nosek, M. Černík,
Language English Country Great Britain
Document type Journal Article
- MeSH
- Water Pollutants, Chemical analysis chemistry MeSH
- Ethylenes analysis chemistry MeSH
- Halogenation MeSH
- Metal Nanoparticles chemistry MeSH
- Groundwater MeSH
- Environmental Restoration and Remediation * MeSH
- Iron MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Czech Republic MeSH
Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migration in the aquifer. In the case of low hydraulic permeability, the migration of nanoparticles is limited, which negatively influences remediation. An application of nZVI reinforced with a DC electric field led to a significant increase in the efficiency of remediation, as demonstrated by long-term monitoring at a former industrial site in Horice (Czech Republic). For the method testing, a 12 × 9 m polygon was defined around well IS4, where the original contamination was predominantly composed of DCE (7300 μg/l), and with a total concentration of chlorinated ethenes of 8880 μg/l. During the first stage of the activities, 49 kg of nZVI was injected and monitored for two years. Subsequently, the electrodes were installed, and for three years, the synergistic action of nZVI within an applied DC field was monitored. Based on 32 monitoring campaigns performed over the six years, the combined method was compared with an application of the only nZVI in technical, environmental and economic terms. Technically, the method requires annual reinstallation of anodes as a result of their oxidative disintegration. Environmentally, the method provides significantly improved chlorinated ethane reduction, remediation of low permeable zones, and extended efficiency. Economically, the method is five times cheaper when compared to the nZVI used alone.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20023081
- 003
- CZ-PrNML
- 005
- 20201214125237.0
- 007
- ta
- 008
- 201125s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.chemosphere.2019.125576 $2 doi
- 035 __
- $a (PubMed)31855757
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Černíková, Martina $u Faculty of Economics, Technical University of Liberec, Studentska 2, Liberec, Czech Republic.
- 245 10
- $a Combination of nZVI and DC for the in-situ remediation of chlorinated ethenes: An environmental and economic case study / $c M. Černíková, J. Nosek, M. Černík,
- 520 9_
- $a Over the past two decades, the use of nanoscale zero-valent iron (nZVI) has emerged as a standard method of contaminated groundwater remediation. The effectiveness of this method depends on key intrinsic hydrogeological parameters, which can affect both reactivity of the nanoparticles and their migration in the aquifer. In the case of low hydraulic permeability, the migration of nanoparticles is limited, which negatively influences remediation. An application of nZVI reinforced with a DC electric field led to a significant increase in the efficiency of remediation, as demonstrated by long-term monitoring at a former industrial site in Horice (Czech Republic). For the method testing, a 12 × 9 m polygon was defined around well IS4, where the original contamination was predominantly composed of DCE (7300 μg/l), and with a total concentration of chlorinated ethenes of 8880 μg/l. During the first stage of the activities, 49 kg of nZVI was injected and monitored for two years. Subsequently, the electrodes were installed, and for three years, the synergistic action of nZVI within an applied DC field was monitored. Based on 32 monitoring campaigns performed over the six years, the combined method was compared with an application of the only nZVI in technical, environmental and economic terms. Technically, the method requires annual reinstallation of anodes as a result of their oxidative disintegration. Environmentally, the method provides significantly improved chlorinated ethane reduction, remediation of low permeable zones, and extended efficiency. Economically, the method is five times cheaper when compared to the nZVI used alone.
- 650 12
- $a regenerace a remediace životního prostředí $7 D052918
- 650 _2
- $a ethyleny $x analýza $x chemie $7 D005030
- 650 _2
- $a podzemní voda $7 D060587
- 650 _2
- $a halogenace $7 D054879
- 650 _2
- $a železo $7 D007501
- 650 _2
- $a kovové nanočástice $x chemie $7 D053768
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $x chemie $7 D014874
- 651 _2
- $a Česká republika $7 D018153
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Nosek, Jaroslav $u Institute for Nanomaterials, Advanced Technologies and Innovation, Technical University of Liberec, Studentska 2, Liberec, Czech Republic.
- 700 1_
- $a Černík, Miroslav $u Institute for Nanomaterials, Advanced Technologies and Innovation, Technical University of Liberec, Studentska 2, Liberec, Czech Republic. Electronic address: miroslav.cernik@tul.cz.
- 773 0_
- $w MED00002124 $t Chemosphere $x 1879-1298 $g Roč. 245, č. - (2020), s. 125576
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31855757 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201214125237 $b ABA008
- 999 __
- $a ok $b bmc $g 1595400 $s 1113757
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 245 $c - $d 125576 $e 20191210 $i 1879-1298 $m Chemosphere $n Chemosphere $x MED00002124
- LZP __
- $a Pubmed-20201125