• Je něco špatně v tomto záznamu ?

An iBody-based lateral flow assay for semi-quantitative determination of His-tagged protein concentration

R. Kryštůfek, P. Šácha,

. 2019 ; 473 (-) : 112640. [pub] 20190807

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20023636

The polyhistidine tag (His-tag) is one of the most commonly used epitope tags in protein engineering. While His-tagged proteins can be detected reliably using immunological methods such as ELISA and Western blot, these methods are costly and time-intensive, necessitating more facile solutions for preliminary qualitative determination and concentration estimation. To this end, we present a rapid test strip assay based on iBody antibody mimetics that target the His-tag. We compare this strategy to commercial antibody-based assays and discuss the advantages and caveats of lateral flow assay design. Our test strip detected a panel of His-tagged proteins with different tag attachment strategies with a visual detection limit of 1 μM and densitometric detection limit of 0.5 μM. Due to its chemical nature, the presented assay exhibits wide reagent compatibility in comparison to antibody-based assays.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20023636
003      
CZ-PrNML
005      
20201214130656.0
007      
ta
008      
201125s2019 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jim.2019.112640 $2 doi
035    __
$a (PubMed)31400409
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Kryštůfek, Robin $u Institute of Organic Chemistry and Biochemistry, The Czech Academy of Sciences, Flemingovo n. 2, 16610 Prague 6, Czech Republic.
245    13
$a An iBody-based lateral flow assay for semi-quantitative determination of His-tagged protein concentration / $c R. Kryštůfek, P. Šácha,
520    9_
$a The polyhistidine tag (His-tag) is one of the most commonly used epitope tags in protein engineering. While His-tagged proteins can be detected reliably using immunological methods such as ELISA and Western blot, these methods are costly and time-intensive, necessitating more facile solutions for preliminary qualitative determination and concentration estimation. To this end, we present a rapid test strip assay based on iBody antibody mimetics that target the His-tag. We compare this strategy to commercial antibody-based assays and discuss the advantages and caveats of lateral flow assay design. Our test strip detected a panel of His-tagged proteins with different tag attachment strategies with a visual detection limit of 1 μM and densitometric detection limit of 0.5 μM. Due to its chemical nature, the presented assay exhibits wide reagent compatibility in comparison to antibody-based assays.
650    _2
$a protilátky $x imunologie $7 D000906
650    _2
$a histidin $x chemie $x imunologie $7 D006639
650    _2
$a limita detekce $7 D057230
650    _2
$a proteiny $x analýza $7 D011506
650    _2
$a reagenční papírky $7 D011934
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Šácha, Pavel $u Institute of Organic Chemistry and Biochemistry, The Czech Academy of Sciences, Flemingovo n. 2, 16610 Prague 6, Czech Republic. Electronic address: pavelsacha@gmail.com.
773    0_
$w MED00010028 $t Journal of immunological methods $x 1872-7905 $g Roč. 473, č. - (2019), s. 112640
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31400409 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201214130655 $b ABA008
999    __
$a ok $b bmc $g 1595955 $s 1114312
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 473 $c - $d 112640 $e 20190807 $i 1872-7905 $m Journal of immunological methods $n J Immunol Methods $x MED00010028
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...