Something wrong with this record ?
PSEUDO-3D IMRT VERIFICATION WITH EBT3 RADIOCHROMIC FILM
T. Hanušová, I. Horáková, I. Koniarová,
Language English Country Great Britain
Document type Journal Article
PubMed
31943097
DOI
10.1093/rpd/ncz232
Knihovny.cz E-resources
- MeSH
- Radiotherapy Dosage MeSH
- Phantoms, Imaging * MeSH
- Film Dosimetry instrumentation methods MeSH
- Humans MeSH
- Prostatic Neoplasms radiotherapy MeSH
- Radiotherapy Planning, Computer-Assisted instrumentation methods MeSH
- Radiotherapy, Intensity-Modulated instrumentation methods MeSH
- Gamma Rays MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources-a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I'mRT.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20025335
- 003
- CZ-PrNML
- 005
- 20201222153814.0
- 007
- ta
- 008
- 201125s2019 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncz232 $2 doi
- 035 __
- $a (PubMed)31943097
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Hanušová, Tereza $u Department of Dosimetry and Application of Ionizing Radiation, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, 115 19 Praha 1, Czech Republic.
- 245 10
- $a PSEUDO-3D IMRT VERIFICATION WITH EBT3 RADIOCHROMIC FILM / $c T. Hanušová, I. Horáková, I. Koniarová,
- 520 9_
- $a This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources-a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I'mRT.
- 650 _2
- $a filmová dozimetrie $x přístrojové vybavení $x metody $7 D005373
- 650 _2
- $a záření gama $7 D005720
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a fantomy radiodiagnostické $7 D019047
- 650 _2
- $a nádory prostaty $x radioterapie $7 D011471
- 650 _2
- $a celková dávka radioterapie $7 D011879
- 650 _2
- $a plánování radioterapie pomocí počítače $x přístrojové vybavení $x metody $7 D011880
- 650 _2
- $a radioterapie s modulovanou intenzitou $x přístrojové vybavení $x metody $7 D050397
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Horáková, Ivana $u National Radiation Protection Institute, Bartoškova 28, 140 00 Praha 4, Czech Republic.
- 700 1_
- $a Koniarová, Irena $u Department of Dosimetry and Application of Ionizing Radiation, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, 115 19 Praha 1, Czech Republic. National Radiation Protection Institute, Bartoškova 28, 140 00 Praha 4, Czech Republic.
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 362-366
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31943097 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201222153811 $b ABA008
- 999 __
- $a ok $b bmc $g 1599480 $s 1116021
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 186 $c 2-3 $d 362-366 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20201125