PSEUDO-3D IMRT VERIFICATION WITH EBT3 RADIOCHROMIC FILM

T. Hanušová, I. Horáková, I. Koniarová,

. 2019 ; 186 (2-3) : 362-366. [pub] 2019Dec31

Language English Country Great Britain

Document type Journal Article

This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources-a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I'mRT.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025335
003      
CZ-PrNML
005      
20201222153814.0
007      
ta
008      
201125s2019 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncz232 $2 doi
035    __
$a (PubMed)31943097
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Hanušová, Tereza $u Department of Dosimetry and Application of Ionizing Radiation, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, 115 19 Praha 1, Czech Republic.
245    10
$a PSEUDO-3D IMRT VERIFICATION WITH EBT3 RADIOCHROMIC FILM / $c T. Hanušová, I. Horáková, I. Koniarová,
520    9_
$a This work proposes a new method for pseudo-3D verification of intensity-modulated radiation therapy (IMRT) dose distributions. Unlike commercial solutions, it uses measured doses only for gamma evaluation. Its resolution is far better than with electronic detectors within the measured plane and comparable in other directions. It is readily available at clinics because it uses existing resources-a slab phantom and EBT3 films. The method was tested on six IMRT clinical cases. An in-house code for 2D and pseudo-3D gamma analysis was written in MATLAB and compared to OmniPro I'mRT.
650    _2
$a filmová dozimetrie $x přístrojové vybavení $x metody $7 D005373
650    _2
$a záření gama $7 D005720
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    12
$a fantomy radiodiagnostické $7 D019047
650    _2
$a nádory prostaty $x radioterapie $7 D011471
650    _2
$a celková dávka radioterapie $7 D011879
650    _2
$a plánování radioterapie pomocí počítače $x přístrojové vybavení $x metody $7 D011880
650    _2
$a radioterapie s modulovanou intenzitou $x přístrojové vybavení $x metody $7 D050397
655    _2
$a časopisecké články $7 D016428
700    1_
$a Horáková, Ivana $u National Radiation Protection Institute, Bartoškova 28, 140 00 Praha 4, Czech Republic.
700    1_
$a Koniarová, Irena $u Department of Dosimetry and Application of Ionizing Radiation, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Břehová 7, 115 19 Praha 1, Czech Republic. National Radiation Protection Institute, Bartoškova 28, 140 00 Praha 4, Czech Republic.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 362-366
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31943097 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222153811 $b ABA008
999    __
$a ok $b bmc $g 1599480 $s 1116021
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 186 $c 2-3 $d 362-366 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20201125

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...