Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Multi-lead vs single-lead Tpeak -T end interval measurements for prediction of reperfusion ventricular tachyarrhythmias

K. Sedova, V. Galinyte, N. Arteyeva, J. Hejda, O. Bernikova, P. Kneppo, J. Azarov,

. 2019 ; 30 (10) : 2090-2097. [pub] 20190821

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20025616

Grantová podpora
SGS18/160/OHK4/2T/17 Ceské Vysoké Ucení Technické v Praze - International
АААА-А18-118012290365-2Disclosures: None. Ural Branch of Russian Academy of Sciences - International

INTRODUCTION: Electrocardiographic Tpeak -Tend interval (Tp-Te) is a promising marker for the prediction of ventricular tachycardia and/or ventricular fibrillation (VT/VF). The study was aimed to compare single-lead vs multilead Tp-Te variables as VT/VF predictors in experimental ischemia/reperfusion model. METHODS AND RESULTS: Computer simulations were done using the ECGSIM model with an ischemic region set in anterior left ventricular apex. In 18 anesthetized cats, myocardial ischemia was induced by 30-minute ligation of left anterior descending coronary artery followed by reperfusion. Body surface ECGs in limb leads and modified precordial leads were recorded. Tp-Te was detected automatically in individual leads with a custom-designed parametric algorithm. Tp-Te dispersion and total Tp-Te were calculated as a difference between the maximal and minimal value of individual Tp-Te(s) and an interval between the earliest Tpeak and the latest Tend throughout all leads, respectively. Simulations showed that the increase of local, but not total, dispersion of repolarization characteristic for ischemic damage led to nonuniform shortening of T-peak times across 12 standard leads, which in turn resulted in the increase of single-lead Tp-Te(s), total Tp-Te and Tp-Te dispersion. Animals experienced VT/VF showed increased Tp-Te dispersion and total Tp-Te during reperfusion. In univariate logistic regression analysis, only the Tp-Te dispersion at the beginning of reperfusion was associated with the VT/VF incidence. According to ROC curve analysis, the optimal cut-off value of the Tp-Te dispersion was 17 ms (sensitivity 0.71, specificity 0.80). CONCLUSIONS: The reperfusion VT/VFs were independently predicted by increased Tp-Te dispersion, which suggests the importance of multi-lead evaluation of Tp-Te intervals.

000      
00000naa a2200000 a 4500
001      
bmc20025616
003      
CZ-PrNML
005      
20201222155314.0
007      
ta
008      
201125s2019 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1111/jce.14105 $2 doi
035    __
$a (PubMed)31402531
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Sedova, Ksenia $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
245    10
$a Multi-lead vs single-lead Tpeak -T end interval measurements for prediction of reperfusion ventricular tachyarrhythmias / $c K. Sedova, V. Galinyte, N. Arteyeva, J. Hejda, O. Bernikova, P. Kneppo, J. Azarov,
520    9_
$a INTRODUCTION: Electrocardiographic Tpeak -Tend interval (Tp-Te) is a promising marker for the prediction of ventricular tachycardia and/or ventricular fibrillation (VT/VF). The study was aimed to compare single-lead vs multilead Tp-Te variables as VT/VF predictors in experimental ischemia/reperfusion model. METHODS AND RESULTS: Computer simulations were done using the ECGSIM model with an ischemic region set in anterior left ventricular apex. In 18 anesthetized cats, myocardial ischemia was induced by 30-minute ligation of left anterior descending coronary artery followed by reperfusion. Body surface ECGs in limb leads and modified precordial leads were recorded. Tp-Te was detected automatically in individual leads with a custom-designed parametric algorithm. Tp-Te dispersion and total Tp-Te were calculated as a difference between the maximal and minimal value of individual Tp-Te(s) and an interval between the earliest Tpeak and the latest Tend throughout all leads, respectively. Simulations showed that the increase of local, but not total, dispersion of repolarization characteristic for ischemic damage led to nonuniform shortening of T-peak times across 12 standard leads, which in turn resulted in the increase of single-lead Tp-Te(s), total Tp-Te and Tp-Te dispersion. Animals experienced VT/VF showed increased Tp-Te dispersion and total Tp-Te during reperfusion. In univariate logistic regression analysis, only the Tp-Te dispersion at the beginning of reperfusion was associated with the VT/VF incidence. According to ROC curve analysis, the optimal cut-off value of the Tp-Te dispersion was 17 ms (sensitivity 0.71, specificity 0.80). CONCLUSIONS: The reperfusion VT/VFs were independently predicted by increased Tp-Te dispersion, which suggests the importance of multi-lead evaluation of Tp-Te intervals.
650    12
$a akční potenciály $7 D000200
650    _2
$a zvířata $7 D000818
650    _2
$a kočky $7 D002415
650    _2
$a počítačová simulace $7 D003198
650    _2
$a modely nemocí na zvířatech $7 D004195
650    12
$a elektrokardiografie $7 D004562
650    _2
$a ženské pohlaví $7 D005260
650    12
$a srdeční frekvence $7 D006339
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a modely kardiovaskulární $7 D008955
650    _2
$a reperfuzní poškození myokardu $x diagnóza $x etiologie $x patofyziologie $7 D015428
650    _2
$a prediktivní hodnota testů $7 D011237
650    _2
$a rizikové faktory $7 D012307
650    _2
$a komorová tachykardie $x diagnóza $x etiologie $x patofyziologie $7 D017180
650    _2
$a časové faktory $7 D013997
650    _2
$a fibrilace komor $x diagnóza $x etiologie $x patofyziologie $7 D014693
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Galinyte, Viktorija $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
700    1_
$a Arteyeva, Natalia $u Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, Syktyvkar, Russia.
700    1_
$a Hejda, Jan $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
700    1_
$a Bernikova, Olesya $u Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, Syktyvkar, Russia.
700    1_
$a Kneppo, Peter $u Department of Biomedical Technology, Faculty of Biomedical Engineering, Czech Technical University in Prague, Kladno, Czech Republic.
700    1_
$a Azarov, Jan $u Department of Cardiac Physiology, Institute of Physiology, Komi Science Center, Ural Branch, Russian Academy of Sciences, Syktyvkar, Russia. Department of Physiology, Medical Institute of Pitirim Sorokin Syktyvkar State University, Syktyvkar, Russia.
773    0_
$w MED00002569 $t Journal of cardiovascular electrophysiology $x 1540-8167 $g Roč. 30, č. 10 (2019), s. 2090-2097
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31402531 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222155310 $b ABA008
999    __
$a ok $b bmc $g 1599761 $s 1116302
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 30 $c 10 $d 2090-2097 $e 20190821 $i 1540-8167 $m Journal of cardiovascular electrophysiology $n J Cardiovasc Electrophysiol $x MED00002569
GRA    __
$a SGS18/160/OHK4/2T/17 $p Ceské Vysoké Ucení Technické v Praze $2 International
GRA    __
$a АААА-А18-118012290365-2Disclosures: None. $p Ural Branch of Russian Academy of Sciences $2 International
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace