-
Je něco špatně v tomto záznamu ?
Consideration of stiffness of wall layers is decisive for patient-specific analysis of carotid artery with atheroma
O. Lisický, A. Malá, Z. Bednařík, T. Novotný, J. Burša,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
Public Library of Science (PLoS)
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2006-12-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-10-01
Medline Complete (EBSCOhost)
od 2008-01-01
Nursing & Allied Health Database (ProQuest)
od 2006-12-01
Health & Medicine (ProQuest)
od 2006-12-01
Public Health Database (ProQuest)
od 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
- MeSH
- analýza metodou konečných prvků MeSH
- arteriae carotides diagnostické zobrazování patologie MeSH
- aterosklerotický plát diagnostické zobrazování patologie MeSH
- biomechanika MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mechanické jevy * MeSH
- modely kardiovaskulární MeSH
- počítačové modelování podle konkrétního pacienta * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The paper deals with the impact of chosen geometric and material factors on maximal stresses in carotid atherosclerotic plaque calculated using patient-specific finite element models. These stresses are believed to be decisive for the plaque vulnerability but all applied models suffer from inaccuracy of input data, especially when obtained in vivo only. One hundred computational models based on ex vivo MRI are used to investigate the impact of wall thickness, MRI slice thickness, lipid core and fibrous tissue stiffness, and media anisotropy on the calculated peak plaque and peak cap stresses. The investigated factors are taken as continuous in the range based on published experimental results, only the impact of anisotropy is evaluated by comparison with a corresponding isotropic model. Design of Experiment concept is applied to assess the statistical significance of these investigated factors representing uncertainties in the input data of the model. The results show that consideration of realistic properties of arterial wall in the model is decisive for the stress evaluation; assignment of properties of fibrous tissue even to media and adventitia layers as done in some studies may induce up to eightfold overestimation of peak stress. The impact of MRI slice thickness may play a key role when local thin fibrous cap is present. Anisotropy of media layer is insignificant, and the stiffness of fibrous tissue and lipid core may become significant in some combinations.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20027807
- 003
- CZ-PrNML
- 005
- 20241008090119.0
- 007
- ta
- 008
- 210105s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0239447 $2 doi
- 035 __
- $a (PubMed)32991605
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Lisický, Ondřej $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno, Czech Republic.
- 245 10
- $a Consideration of stiffness of wall layers is decisive for patient-specific analysis of carotid artery with atheroma / $c O. Lisický, A. Malá, Z. Bednařík, T. Novotný, J. Burša,
- 520 9_
- $a The paper deals with the impact of chosen geometric and material factors on maximal stresses in carotid atherosclerotic plaque calculated using patient-specific finite element models. These stresses are believed to be decisive for the plaque vulnerability but all applied models suffer from inaccuracy of input data, especially when obtained in vivo only. One hundred computational models based on ex vivo MRI are used to investigate the impact of wall thickness, MRI slice thickness, lipid core and fibrous tissue stiffness, and media anisotropy on the calculated peak plaque and peak cap stresses. The investigated factors are taken as continuous in the range based on published experimental results, only the impact of anisotropy is evaluated by comparison with a corresponding isotropic model. Design of Experiment concept is applied to assess the statistical significance of these investigated factors representing uncertainties in the input data of the model. The results show that consideration of realistic properties of arterial wall in the model is decisive for the stress evaluation; assignment of properties of fibrous tissue even to media and adventitia layers as done in some studies may induce up to eightfold overestimation of peak stress. The impact of MRI slice thickness may play a key role when local thin fibrous cap is present. Anisotropy of media layer is insignificant, and the stiffness of fibrous tissue and lipid core may become significant in some combinations.
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a arteriae carotides $x diagnostické zobrazování $x patologie $7 D002339
- 650 _2
- $a analýza metodou konečných prvků $7 D020342
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a magnetická rezonanční tomografie $7 D008279
- 650 12
- $a mechanické jevy $7 D055595
- 650 _2
- $a modely kardiovaskulární $7 D008955
- 650 12
- $a počítačové modelování podle konkrétního pacienta $7 D066230
- 650 _2
- $a aterosklerotický plát $x diagnostické zobrazování $x patologie $7 D058226
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Malá, Aneta $u Institute of Scientific Instruments, The Czech Academy of Science, Brno, Czech Republic.
- 700 1_
- $a Bednařík, Zdeněk $u 1st Department of Pathology, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Novotný, Tomáš $u 2nd Department of Surgery, St. Anne's University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Burša, Jiří, $d 1954- $u Institute of Solid Mechanics, Mechatronics and Biomechanics, Brno University of Technology, Brno, Czech Republic. $7 xx0034888
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 15, č. 9 (2020), s. e0239447
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32991605 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20241008090116 $b ABA008
- 999 __
- $a ok $b bmc $g 1608142 $s 1118987
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 15 $c 9 $d e0239447 $e 20200929 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- LZP __
- $a Pubmed-20210105