-
Something wrong with this record ?
Effects of Carrying Police Equipment on Spatiotemporal and Kinetic Gait Parameters in First Year Police Officers
M. Kasović, L. Štefan, K. Borovec, M. Zvonař, J. Cacek,
Language English Country Switzerland
Document type Journal Article
NLK
Free Medical Journals
from 2004
PubMed Central
from 2005
Europe PubMed Central
from 2005
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2004-01-01
Open Access Digital Library
from 2005-01-01
Medline Complete (EBSCOhost)
from 2008-12-01
Health & Medicine (ProQuest)
from 2009-01-01
Public Health Database (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2004
- MeSH
- Biomechanical Phenomena MeSH
- Gait * MeSH
- Walking * MeSH
- Adult MeSH
- Humans MeSH
- Young Adult MeSH
- Foot MeSH
- Police * MeSH
- Equipment Failure MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Young Adult MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
The main purpose of the study was to explore the effects of carrying police equipment on spatiotemporal and kinetic gait parameters. Two-hundred and seventy-five healthy men and women attending police academy (32% women) were randomly recruited. Gait analysis without and with a police equipment load (≈3.5 kg) was analyzed using the Zebris pressure platform. Differences and effect sizes were calculated using a Student t-test and Wilcoxon test for dependent samples and Cohen's D statistics. In both men and women, carrying police equipment significantly increased the foot rotation (effect size 0.13-0.25), step width (0.13-0.33), step time (0.25), stride time (0.13-0.25) and peak plantar pressure beneath the forefoot (0.16-0.30), midfoot (0.15-0.32) and hindfoot (0.13-0.25) region of the foot. Significant reductions in the step length (0.12-0.25), stride length (0.14-0.23), cadence (0.15-0.28) and walking speed (0.20-0.22) were observed in both sexes. Although significant, the effect sizes were mostly trivial in men and small in women. Our study shows significant changes in the spatiotemporal and kinetic gait parameters when carrying police equipment for both men and women. Although the effect sizes are trivial to small, carrying police equipment of ≈3.5 kg may have a negative impact on gait characteristics in first-year police officers.
Faculty of Kinesiology University of Zagreb 10 000 Zagreb Croatia
Faculty of Science Masaryk University 62 500 Brno Czech Republic
Faculty of Sports Studies Masaryk University 62 500 Brno Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20027944
- 003
- CZ-PrNML
- 005
- 20210114152645.0
- 007
- ta
- 008
- 210105s2020 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/ijerph17165750 $2 doi
- 035 __
- $a (PubMed)32784845
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Kasović, Mario $u Faculty of Kinesiology, University of Zagreb, 10 000 Zagreb, Croatia. Faculty of Sports Studies, Masaryk University, 62 500 Brno, Czech Republic.
- 245 10
- $a Effects of Carrying Police Equipment on Spatiotemporal and Kinetic Gait Parameters in First Year Police Officers / $c M. Kasović, L. Štefan, K. Borovec, M. Zvonař, J. Cacek,
- 520 9_
- $a The main purpose of the study was to explore the effects of carrying police equipment on spatiotemporal and kinetic gait parameters. Two-hundred and seventy-five healthy men and women attending police academy (32% women) were randomly recruited. Gait analysis without and with a police equipment load (≈3.5 kg) was analyzed using the Zebris pressure platform. Differences and effect sizes were calculated using a Student t-test and Wilcoxon test for dependent samples and Cohen's D statistics. In both men and women, carrying police equipment significantly increased the foot rotation (effect size 0.13-0.25), step width (0.13-0.33), step time (0.25), stride time (0.13-0.25) and peak plantar pressure beneath the forefoot (0.16-0.30), midfoot (0.15-0.32) and hindfoot (0.13-0.25) region of the foot. Significant reductions in the step length (0.12-0.25), stride length (0.14-0.23), cadence (0.15-0.28) and walking speed (0.20-0.22) were observed in both sexes. Although significant, the effect sizes were mostly trivial in men and small in women. Our study shows significant changes in the spatiotemporal and kinetic gait parameters when carrying police equipment for both men and women. Although the effect sizes are trivial to small, carrying police equipment of ≈3.5 kg may have a negative impact on gait characteristics in first-year police officers.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a selhání zařízení $7 D004868
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a noha (od hlezna dolů) $7 D005528
- 650 12
- $a chůze (způsob) $7 D005684
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a policie $7 D016495
- 650 12
- $a chůze $7 D016138
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Štefan, Lovro $u Faculty of Kinesiology, University of Zagreb, 10 000 Zagreb, Croatia.
- 700 1_
- $a Borovec, Krunoslav $u Police Academy, Police College, 10 000 Zagreb, Croatia.
- 700 1_
- $a Zvonař, Martin $u Faculty of Science, Masaryk University, 62 500 Brno, Czech Republic.
- 700 1_
- $a Cacek, Jan $u Faculty of Sports Studies, Masaryk University, 62 500 Brno, Czech Republic.
- 773 0_
- $w MED00176090 $t International journal of environmental research and public health $x 1660-4601 $g Roč. 17, č. 16 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32784845 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114152643 $b ABA008
- 999 __
- $a ok $b bmc $g 1608279 $s 1119124
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 17 $c 16 $e 20200809 $i 1660-4601 $m International journal of environmental research and public health $n Int. j. environ. res. public health $x MED00176090
- LZP __
- $a Pubmed-20210105