Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Heat treatment dependent cytotoxicity of silicalite-1 films deposited on Ti-6Al-4V alloy evaluated by bone-derived cells

I. Nemcakova, I. Jirka, M. Doubkova, L. Bacakova,

. 2020 ; 10 (1) : 9456. [pub] 20200611

Jazyk angličtina Země Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20028097

A silicalite-1 film (SF) deposited on Ti-6Al-4V alloy was investigated in this study as a promising coating for metallic implants. Two forms of SFs were prepared: as-synthesized SFs (SF-RT), and SFs heated up to 500 °C (SF-500) to remove the excess of template species from the SF surface. The SFs were characterized in detail by X-ray photoelectron spectroscopy (XPS), by Fourier transform infrared spectroscopy (FTIR), by scanning electron microscopy (SEM) and water contact angle measurements (WCA). Two types of bone-derived cells (hFOB 1.19 non-tumor fetal osteoblast cell line and U-2 OS osteosarcoma cell line) were used for a biocompatibility assessment. The initial adhesion of hFOB 1.19 cells, evaluated by cell numbers and cell spreading area, was better supported by SF-500 than by SF-RT. While no increase in cell membrane damage, in ROS generation and in TNF-alpha secretion of bone-derived cells grown on both SFs was found, gamma H2AX staining revealed an elevated DNA damage response of U-2 OS cells grown on heat-treated samples (SF-500). This study also discusses differences between osteosarcoma cell lines and non-tumor osteoblastic cells, stressing the importance of choosing the right cell type model.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20028097
003      
CZ-PrNML
005      
20210114152956.0
007      
ta
008      
210105s2020 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-020-66228-x $2 doi
035    __
$a (PubMed)32528137
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Nemcakova, Ivana $u Institute of Physiology of the Czech Academy of Sciences, v.v.i., Videnska 1083, 142 20, Prague 4, Czech Republic. ivana.nemcakova@fgu.cas.cz.
245    10
$a Heat treatment dependent cytotoxicity of silicalite-1 films deposited on Ti-6Al-4V alloy evaluated by bone-derived cells / $c I. Nemcakova, I. Jirka, M. Doubkova, L. Bacakova,
520    9_
$a A silicalite-1 film (SF) deposited on Ti-6Al-4V alloy was investigated in this study as a promising coating for metallic implants. Two forms of SFs were prepared: as-synthesized SFs (SF-RT), and SFs heated up to 500 °C (SF-500) to remove the excess of template species from the SF surface. The SFs were characterized in detail by X-ray photoelectron spectroscopy (XPS), by Fourier transform infrared spectroscopy (FTIR), by scanning electron microscopy (SEM) and water contact angle measurements (WCA). Two types of bone-derived cells (hFOB 1.19 non-tumor fetal osteoblast cell line and U-2 OS osteosarcoma cell line) were used for a biocompatibility assessment. The initial adhesion of hFOB 1.19 cells, evaluated by cell numbers and cell spreading area, was better supported by SF-500 than by SF-RT. While no increase in cell membrane damage, in ROS generation and in TNF-alpha secretion of bone-derived cells grown on both SFs was found, gamma H2AX staining revealed an elevated DNA damage response of U-2 OS cells grown on heat-treated samples (SF-500). This study also discusses differences between osteosarcoma cell lines and non-tumor osteoblastic cells, stressing the importance of choosing the right cell type model.
650    _2
$a biokompatibilní materiály $x chemie $7 D001672
650    _2
$a buněčné linie $7 D002460
650    _2
$a nádorové buněčné linie $7 D045744
650    _2
$a buněčná membrána $x účinky léků $7 D002462
650    _2
$a proliferace buněk $x účinky léků $7 D049109
650    _2
$a cytotoxiny $x chemie $x farmakologie $7 D003603
650    _2
$a vysoká teplota $7 D006358
650    _2
$a lidé $7 D006801
650    _2
$a testování materiálů $x metody $7 D008422
650    _2
$a mikroskopie elektronová rastrovací $x metody $7 D008855
650    _2
$a osteoblasty $x účinky léků $7 D010006
650    _2
$a osteocyty $x účinky léků $7 D010011
650    _2
$a fotoelektronová spektroskopie $x metody $7 D056951
650    _2
$a povrchové vlastnosti $x účinky léků $7 D013499
650    _2
$a titan $x chemie $7 D014025
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Jirka, Ivan $u J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences, v.v.i., Dolejskova 3, 182 23, Prague 8, Czech Republic.
700    1_
$a Doubkova, Martina $u Institute of Physiology of the Czech Academy of Sciences, v.v.i., Videnska 1083, 142 20, Prague 4, Czech Republic. Second Faculty of Medicine, Charles University, V Uvalu 84, 150 06, Prague 5, Czech Republic.
700    1_
$a Bacakova, Lucie $u Institute of Physiology of the Czech Academy of Sciences, v.v.i., Videnska 1083, 142 20, Prague 4, Czech Republic.
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 10, č. 1 (2020), s. 9456
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32528137 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20210105 $b ABA008
991    __
$a 20210114152953 $b ABA008
999    __
$a ok $b bmc $g 1608432 $s 1119277
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 10 $c 1 $d 9456 $e 20200611 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
LZP    __
$a Pubmed-20210105

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...