-
Something wrong with this record ?
Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration
E. Fialova, PPS. Otahal, J. Vosahlik, M. Mazanova,
Language English Country Switzerland
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 2004
PubMed Central
from 2005
Europe PubMed Central
from 2005
ProQuest Central
from 2009-01-01
Open Access Digital Library
from 2004-01-01
Open Access Digital Library
from 2005-01-01
Medline Complete (EBSCOhost)
from 2008-12-01
Health & Medicine (ProQuest)
from 2009-01-01
Public Health Database (ProQuest)
from 2009-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2004
- MeSH
- Atmosphere MeSH
- Radiation Monitoring * MeSH
- Air Pollutants, Radioactive analysis MeSH
- Radon analysis MeSH
- Air Pollution, Indoor analysis MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source-partialized if necessary-through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1-3.5 m·s-1 can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m-3 to 300 Bq·m-3.
Czech Metrological Institute 102 00 Prague Czech Republic
National Institute for Nuclear Biological and Chemical protection 262 31 Milin Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028380
- 003
- CZ-PrNML
- 005
- 20210114153705.0
- 007
- ta
- 008
- 210105s2020 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/ijerph17061904 $2 doi
- 035 __
- $a (PubMed)32183418
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Fialova, Eliska $u National Institute for Nuclear, Biological and Chemical protection (SUJCHBO, v.v.i.), 262 31 Milin, Czech Republic.
- 245 10
- $a Equipment for Testing Measuring Devices at a Low-Level Radon Activity Concentration / $c E. Fialova, PPS. Otahal, J. Vosahlik, M. Mazanova,
- 520 9_
- $a The National Institute for Nuclear, Biological, and Chemical Protection, under the European project 16ENV10 MetroRADON (the European metrology program for innovation and research, EMPIR), has developed unique equipment for the testing of measuring devices at low-level radon activity concentrations. The equipment consists particularly of an airtight low-level radon chamber (LLRCH) with an inner volume of 324 liters; a Rn-222 type RF 5 flow-through source with a Ra-226 activity of 4.955 kBq developed by Czech Metrological Institute within the above-mentioned project; and a pressure vessel as a radon-free air source. The mass flow controller of the Bronkhorst EL-Flow type is a part of the apparatus and ensures the requested airflow through the radon source-partialized if necessary-through the chamber. The homogeneity of the atmosphere in the chamber is ensured by means of a continuously regulated fan (airflows in the range of 0.1-3.5 m·s-1 can be established). Another important chamber component is the measuring device of climatic conditions, since temperature, air pressure, and relative humidity must be determined. The construction of the equipment allows the time-stable radon activity concentration to be maintained at a precise level for several days. Radon concentration values can be arbitrarily and continuously set in the range from 100 Bq·m-3 to 300 Bq·m-3.
- 650 _2
- $a radioaktivní látky znečišťující vzduch $x analýza $7 D000396
- 650 _2
- $a znečištění vzduchu ve vnitřním prostředí $x analýza $7 D016902
- 650 _2
- $a atmosféra $7 D001272
- 650 12
- $a monitorování radiace $7 D011834
- 650 _2
- $a radon $x analýza $7 D011886
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Otahal, Petr P S $u National Institute for Nuclear, Biological and Chemical protection (SUJCHBO, v.v.i.), 262 31 Milin, Czech Republic.
- 700 1_
- $a Vosahlik, Josef $u National Institute for Nuclear, Biological and Chemical protection (SUJCHBO, v.v.i.), 262 31 Milin, Czech Republic.
- 700 1_
- $a Mazanova, Monika $u Czech Metrological Institute (CMI), 102 00 Prague, Czech Republic.
- 773 0_
- $w MED00176090 $t International journal of environmental research and public health $x 1660-4601 $g Roč. 17, č. 6 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32183418 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114153703 $b ABA008
- 999 __
- $a ok $b bmc $g 1608715 $s 1119560
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 17 $c 6 $e 20200315 $i 1660-4601 $m International journal of environmental research and public health $n Int. j. environ. res. public health $x MED00176090
- LZP __
- $a Pubmed-20210105