Je něco špatně v tomto záznamu ?
A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin
J. Jašprová, A. Dvořák, M. Vecka, M. Leníček, O. Lacina, P. Valášková, M. Zapadlo, R. Plavka, P. Klán, L. Vítek,
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
Nature Open Access
od 2011-12-01
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2011
- MeSH
- bilirubin analogy a deriváty krev chemie MeSH
- chromatografie kapalinová MeSH
- fototerapie metody MeSH
- lidé MeSH
- molekulární struktura MeSH
- novorozenec MeSH
- novorozenecká žloutenka krev terapie MeSH
- sérum chemie MeSH
- tandemová hmotnostní spektrometrie MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted. LR was purified after irradiation of UCB at 460 nm. The assay was tested on human sera from PT-treated neonates. Samples were separated on a HPLC system with a triple quadrupole mass spectrometer detector. The instrument response was linear up to 5.8 and 23.4 mg/dL for LR and UCB, respectively, with submicromolar limits of detection and validity parameters relevant for use in clinical medicine. Exposure of newborns to PT raised serum LR concentrations three-fold (p < 0.01), but the absolute concentrations were low (0.37 ± 0.16 mg/dL), despite a dramatic decrease of serum UCB concentrations (13.6 ± 2.2 vs. 10.3 ± 3.3 mg/dL, p < 0.01). A LC-MS/MS method for the simultaneous determination of LR and UCB in human serum was established and validated for clinical use. This method should help to monitor neonates on PT, as well as to improve our understanding of both the kinetics and biology of bilirubin phototherapy products.
Department of Chemistry and Recetox Faculty of Science Masaryk University Brno Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028391
- 003
- CZ-PrNML
- 005
- 20210114153725.0
- 007
- ta
- 008
- 210105s2020 xxk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1038/s41598-020-61280-z $2 doi
- 035 __
- $a (PubMed)32157102
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Jašprová, Jana $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 245 12
- $a A novel accurate LC-MS/MS method for quantitative determination of Z-lumirubin / $c J. Jašprová, A. Dvořák, M. Vecka, M. Leníček, O. Lacina, P. Valášková, M. Zapadlo, R. Plavka, P. Klán, L. Vítek,
- 520 9_
- $a Although phototherapy (PT) is a standard treatment for neonatal jaundice, no validated clinical methods for determination of bilirubin phototherapy products are available. Thus, the aim of our study was to establish a such method for clinical use. To achieve this aim, a LC-MS/MS assay for simultaneous determination of Z-lumirubin (LR) and unconjugated bilirubin (UCB) was conducted. LR was purified after irradiation of UCB at 460 nm. The assay was tested on human sera from PT-treated neonates. Samples were separated on a HPLC system with a triple quadrupole mass spectrometer detector. The instrument response was linear up to 5.8 and 23.4 mg/dL for LR and UCB, respectively, with submicromolar limits of detection and validity parameters relevant for use in clinical medicine. Exposure of newborns to PT raised serum LR concentrations three-fold (p < 0.01), but the absolute concentrations were low (0.37 ± 0.16 mg/dL), despite a dramatic decrease of serum UCB concentrations (13.6 ± 2.2 vs. 10.3 ± 3.3 mg/dL, p < 0.01). A LC-MS/MS method for the simultaneous determination of LR and UCB in human serum was established and validated for clinical use. This method should help to monitor neonates on PT, as well as to improve our understanding of both the kinetics and biology of bilirubin phototherapy products.
- 650 _2
- $a bilirubin $x analogy a deriváty $x krev $x chemie $7 D001663
- 650 _2
- $a chromatografie kapalinová $7 D002853
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a novorozenec $7 D007231
- 650 _2
- $a novorozenecká žloutenka $x krev $x terapie $7 D007567
- 650 _2
- $a molekulární struktura $7 D015394
- 650 _2
- $a fototerapie $x metody $7 D010789
- 650 _2
- $a sérum $x chemie $7 D044967
- 650 _2
- $a tandemová hmotnostní spektrometrie $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Dvořák, Aleš $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Vecka, Marek $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Leníček, Martin $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Lacina, Ondřej $u HPST, s.r.o., Prague, Czech Republic.
- 700 1_
- $a Valášková, Petra $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Zapadlo, Miloš $u Department of Pediatrics and Neonatology, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Plavka, Richard $u Department of Pediatrics and Neonatology, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic.
- 700 1_
- $a Klán, Petr $u Department of Chemistry and Recetox, Faculty of Science, Masaryk University, Brno, Czech Republic.
- 700 1_
- $a Vítek, Libor $u Institute of Medical Biochemistry and Laboratory Diagnostics, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic. vitek@cesnet.cz. 4th Department of Internal Medicine, Faculty General Hospital and 1st Faculty of Medicine, Charles University, Prague, Czech Republic. vitek@cesnet.cz.
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 10, č. 1 (2020), s. 4411
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32157102 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114153722 $b ABA008
- 999 __
- $a ok $b bmc $g 1608726 $s 1119571
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 10 $c 1 $d 4411 $e 20200310 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20210105