O-Arm Navigated Frameless and Fiducial-Less Deep Brain Stimulation

D. Krahulík, M. Nevrlý, P. Otruba, J. Bardoň, L. Hrabálek, D. Pohlodek, P. Kaňovský, J. Valošek,

. 2020 ; 10 (10) : . [pub] 20200927

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21002048

OBJECT: Deep brain stimulation (DBS) is a very useful procedure for the treatment of idiopathic Parkinson's disease (PD), essential tremor, and dystonia. The authors evaluated the accuracy of the new method used in their center for the placing of DBS electrodes. Electrodes are placed using the intraoperative O-armTM (Medtronic)-controlled frameless and fiducial-less system, NexframeTM (Medtronic). Accuracy was evaluated prospectively in eleven consecutive PD patients (22 electrodes). METHODS: Eleven adult patients with PD were implanted using the Nexframe system without fiducials and with the intraoperative O-arm (Medtronic) system and StealthStationTM S8 navigation (Medtronic). The implantation of DBS leads was performed using multiple-cell microelectrode recording, and intraoperative test stimulation to determine thresholds for stimulation-induced adverse effects. The accuracy was checked in three different steps: (1) using the intraoperative O-arm image and its fusion with preoperative planning, (2) using multiple-cell microelectrode recording and counting the number of microelectrodes with the signal of the subthalamic nucleus (STN) and finally, (3) total error was calculated according to a postoperative CT control image fused to preoperative planning. RESULTS: The total error of the procedure was 1.79 mm; the radial error and the vector error were 171 mm and 163 mm. CONCLUSIONS: Implantation of DBS electrodes using an O-arm navigated frameless and fiducial-less system is a very useful and technically feasible procedure with excellent patient toleration with experienced Nexframe users. The accuracy of the method was confirmed at all three steps, and it is comparable to other published results.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21002048
003      
CZ-PrNML
005      
20220718085921.0
007      
ta
008      
210105s2020 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/brainsci10100683 $2 doi
035    __
$a (PubMed)32992610
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Krahulík, David $u Department of Neurosurgery, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
245    10
$a O-Arm Navigated Frameless and Fiducial-Less Deep Brain Stimulation. / $c D. Krahulík, M. Nevrlý, P. Otruba, J. Bardoň, L. Hrabálek, D. Pohlodek, P. Kaňovský, J. Valošek,
520    9_
$a OBJECT: Deep brain stimulation (DBS) is a very useful procedure for the treatment of idiopathic Parkinson's disease (PD), essential tremor, and dystonia. The authors evaluated the accuracy of the new method used in their center for the placing of DBS electrodes. Electrodes are placed using the intraoperative O-armTM (Medtronic)-controlled frameless and fiducial-less system, NexframeTM (Medtronic). Accuracy was evaluated prospectively in eleven consecutive PD patients (22 electrodes). METHODS: Eleven adult patients with PD were implanted using the Nexframe system without fiducials and with the intraoperative O-arm (Medtronic) system and StealthStationTM S8 navigation (Medtronic). The implantation of DBS leads was performed using multiple-cell microelectrode recording, and intraoperative test stimulation to determine thresholds for stimulation-induced adverse effects. The accuracy was checked in three different steps: (1) using the intraoperative O-arm image and its fusion with preoperative planning, (2) using multiple-cell microelectrode recording and counting the number of microelectrodes with the signal of the subthalamic nucleus (STN) and finally, (3) total error was calculated according to a postoperative CT control image fused to preoperative planning. RESULTS: The total error of the procedure was 1.79 mm; the radial error and the vector error were 171 mm and 163 mm. CONCLUSIONS: Implantation of DBS electrodes using an O-arm navigated frameless and fiducial-less system is a very useful and technically feasible procedure with excellent patient toleration with experienced Nexframe users. The accuracy of the method was confirmed at all three steps, and it is comparable to other published results.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Nevrlý, Martin $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Otruba, Pavel $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Bardoň, Jan $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Hrabálek, Lumír $u Department of Neurosurgery, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Pohlodek, Daniel $u Department of Neurosurgery, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Kaňovský, Petr $u Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic.
700    1_
$a Valošek, Jan, $u Department of Neurosurgery, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic. Department of Neurology, Faculty of Medicine and Dentistry, Palacký University and University Hospital Olomouc, 77900 Olomouc, Czech Republic. $d 1993- $7 xx0274853
773    0_
$w MED00198694 $t Brain sciences $x 2076-3425 $g Roč. 10, č. 10 (2020)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32992610 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20210105 $b ABA008
991    __
$a 20220718085920 $b ABA008
999    __
$a ind $b bmc $g 1614128 $s 1122332
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 10 $c 10 $e 20200927 $i 2076-3425 $m Brain sciences $n Brain Sci $x MED00198694
LZP    __
$a Pubmed-20210105

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...